Web Analytics Made Easy - StatCounter

Water Station Tenders

Get complete information related to latest Water Station Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Station Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Station Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45427822 Due date: 07 Jul, 202607 Jul, 2026 39.97 Lacs
Tender For corrigendum : ca no. ge af no.1 / gur-38 / 2026-27 repair/ maintenance of external water supply, fire fighting system, fire alarm and other connected works in sekhon vihar under ge (af) gurgaon no.01

Central Government/Public Sector

CTN :45481995 Due date: 07 Jul, 202607 Jul, 2026 35.00 Lacs
Tender For corrigendum : maintenance repair to external water supply distribution system replacement of ppr gi ci pipe line repair of pump sets allied works at pocket a b 42 weu and kv school under ge af trivandrum

CTN :45542922 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : providing of annual maintenance services for water purification and conditioning system (version 2) - potable water purification system reverse osmosis or uv based; 3 to 5; package-5 : water purifier and conditioning system maintenance involving basic servicing, ..,annual maintenance services for water purification and conditioning system (version 2) - potable water purification system reverse osmosis or uv based; 3 to 5; package-5 : water purifier and conditioning system maintenance involving basic servicing, ..,amc of integrated security and surveillance system - repair and maintenance of cctv and surveillance system in the residential school for entire campus; non-comprehensive; hardware, software, wireless system; cost of consumables to be provided to se..,amc of integrated security and surveillance system - repair and maintenance of cctv and surveillance system in the residential school for entire campus; non-comprehensive; hardware, software, wireless system; cost of consumables to be provided to se..

Central Government/Public Sector

CTN :45657852 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : providing of repair and overhauling service - potable water purification system reverse osmosis or uv based; hitech; yes; buyer premises

State Government

CTN :45700588 Due date: 02 Jul, 202602 Jul, 2026 4.19 Lacs
Tender For 1) repair of reverse osmosis system 1000 litre per hour with chiller, atm and other allied work. (gram panchayat) 2) providing, supplying, and commisioning of reverse osmosis drinking water system ( anganwadi -5nos ) 3) providing, supplying, and commisioning of reverse osmosis system 25 lph capacity( z p school -3nos ) 4) providing supplying and comissloning of reverse osmosis system 250 lph per hour capacity ( z.p school gaothan )

CTN :45716237 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For providing of repair and overhauling service - potable water purification system reverse osmosis or uv based; coolers,voltas and bluestar water dispenser; yes; buyer premises

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45729353 Due date: 14 Jul, 202614 Jul, 2026 51.39 Lacs
Tender For repair/improvement work in khirkiya drinking water distribution system

State Government

CTN :45732349 Due date: 08 Jul, 202608 Jul, 2026 23.75 Lacs
Tender For eor to augmentation of rain water harvesting system provision of water proofing and repair of door and window at skv (ravi shankar) bawana delhi 110039 school id 1310042
 Loading, Please wait...

Connect us via What's Up