Get complete information related to latest Water Storage Tanks Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Storage Tanks Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Storage Tanks Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45713851 Due date: 25 Jul, 202625 Jul, 2026 55.00 Lacs
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole

Central Government/Public Sector

CTN :45726505 Due date: 20 Jul, 202620 Jul, 2026 45.00 Lacs
Tender For repair/maintenance of diesel generator set with central panel and other connected items at zone 5 and 1(a,b,c) zone 1, 3 (a and b), zone 2 and zone 4 under ge (s) tezpur - maint and servicing of dg set 320-400 kva conopy type with amf panel (if installed ), through authorise service agency of oem , including replacment of defective/wornout parts with new spares such as filters, gaskets, v belts, engine oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of pol tank and radiator etc complete all as specified and directed.note:- 1. spares required for above maint will be measured and paid separately under relevent items of schedule. 2. all breakdown calls should be attended., all as per item no-1 above but for dg set of capacity 180-250 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 125-160 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 40-100 kva complete all as specified and directed, all as per item no-1 above but for dg set of capacity 10-35 kva complete all as specified and directed, supply only fuel filter for 300-400 kva dg set, complete all as specified and directed, supply only fuel filter for 125-250 kva dg set,complete all as specified and directed complete all as specified and directed, supply only fuel filter for 10-100 kva dg set,complete all as specified and directed, supply only lub oil filter for 300-400 kva dg set,complete all as specified and directed, supply only lub oil filter for 125-250 kva dg set,complete all as specified and directed, supply only lub oil filter for 10-100 kva dg set,complete all as specified and directed, supply only air cleaner filter ( inner and outer ) for 300-400 kva dg set, complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 125-250 kva dg set,complete all as specified and directed, supply only air cleaner filter (inner and outer ) for 10-100 kva dg set,complete all as specified and directed, supply only bypass filter for 300-400 kva dg set, complete all as specified and directed, supply only bypass filter for 125-250 kva dg set,complete all as specified and directed, supply only bypass filter for 10-100 kva dg set,complete all as specified and directed, supply only v belt for 300-400 kva dg set, complete all as specified and directed, supply only v belt for 125-250 kva dg set, complete all as specified and directed, supply only v belt for 10-100 kva dg set, complete all as specified and directed, supply only coolant for radiators complete all as specified and directed., supply only engine oil multi grade 15w40 complete all as specified and directed., s & f in repair display control panel ( base card) for 10 to 100 kva dg set complete all as specified and directed ., s & f in repair display control panel (base card) for 125 to 250 kva dg set complete all as specified and directed., s & f in repair display control panel (base card) for 300 to 400 kva dg set complete all as specified and directed., s & f in repair fuel actuator with o ring for 300 to 400 kva dg set complete all as specified and directed., s & f in repair key switch for 10 to 400kva dg set complete all as specified and directed., s & f in repair coolant temperature sensor (coolent control safety) for 10 to 400kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 10 to 100 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 125 to 250 kva dg set complete all as specified and directed., s & f in repair amf controller assy for auto/manual operation for 300 to 400kva dg set complete all as specified and directed., s & f in rep

Central Government And Public Sector

CTN :45615691 Due date: 02 Jul, 202602 Jul, 2026 5.65 Lacs
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35

Central Government And Public Sector

CTN :45617559 Due date: 03 Jul, 202603 Jul, 2026 5.63 Lacs
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

CTN :45742273 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For supply of led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , miniature circuit breakers (mcb) for ac operation marked to is/iec 60898 (part 1) (q2) , plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , rotational moulded polyethylene water storage tanks (v3) conforming to is 12701 (q3) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , cable joint kit suitable for cables up to and including 33 kv (v2) (q3) , pvc insulated copper cable single core and multi core circular sheathed with rigid conductor (v2) isi marked to is 694 (q2) , led batten light (led tube light) (v2) (q2) , led luminaire (recessed luminaire) (ceiling light) conforming to is 10322 (part 5/section 2) (v4) (under bis scheme - ii) (q2) , led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , bathroom or toilet mirror (v3) (q4)

CTN :45627252 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : supply of stainless steel sinks for domestic purposes (v3) as per is 13983 (q2) , rotational moulded polyethylene water storage tanks (v3) conforming to is 12701 (q3) , plastic seats and covers for water - closets as per is 2548 (q3) , screw wood steel 12 mm , varnish clear , nails wire steel 20mm , screw wood steel 65 mm , screw wood steel 50 mm , screw wood steel 15 mm , screw wood steel 30 mm , screw wood steel 40 mm , nails wire steel 40 mm , french polish , pegs alu powder coated , touch wood polish , nails wire steel 12 mm , screw wood steel 35 mm , nails wire steel 25 mm , brush 50 mm , pianotype hings 6 feet long , ss handle for drawar , screw wood steel 20 mm , knob 40 mm , nails wire steel 50 mm , sunmica sheet 2400x1200x1.5 mm thick , fevicol , screw wood steel 25mm , paint synthetic enamel og , lock for drawar , plywood teak face 2400x1200x3.5mm thick , plywood bwr 2400x1200x12 mm thick , cushion size 550x530x100 mm 32 density with tapestry cloth , prelam mdf board 8feetx4feetx18 mm thick , sunmica sheet 2400x1200x1 mm thick , lock for almirah steel , nipple 20mm x300mm , gi tee 20 mm , ptmt ball cock 25 mm complete , union gi 50 mm , hex nipple 20 mm , union gi 40 mm , elbow gi 20 mm , socket reducer 25x50mm , nipple 25mm x300mm , gi 3 way elbow 20 mm , gi tee 25 mm , gi tank nipple 20 mm , elbow gi 25 mm , ptmt ball cock 20 mm complete , bow handle alu 125 mm , cp grating with holw 125 mm , gi bend 15 mm , gi socket 15 mm , gi elbow 15 mm , door stopper alu , nipple 15mmx300mm , cp waste coupling 32 mm , oil putty , cp grating 125 mm , gi nipple 15mmx100 mm , ss but hings 100mm , union gi 15 mm , m seal 100 gms , union gi20 mm , gi socket 20 mm , gi nipple 15mmx150 mm , paint synthetic enamel red , ss but hings 75 mm , gi nipple 15mmx50mm , ptmt grating doom 125 mm , gi tee 15 mm , brush 100 mm , pvc jet fitting for ewc , brush 75 mm , ptmt pvc connection 450 mm long , ptmt grating 150 mm , ptmt grating with hole 125 mm , gi plug 20 mm , gi plug 15 mm , gi 3 way elbow 15 mm , socket reducer 15x20mm , paint synthetic sky blue , bell push pianotype , two way switch 6 amp , lamp holder pendent bakalite , bed switch 6 amp , plywood commercial 8 feet x4feetx6 mm , plywood commercial 8 feet x4feetx12 mm , plywood bwr8feetx4 feetx4 mm , plywood bwr 8feetx4feetx8mm , mirror cabinet in ptmt , ss wire cloth 0.56 mm dia with aperture 1.14 , looking mirror pvc of size 450x600x3mmthick , hydraulic door closure , cp soap dish , cp sink cock 15mm , wiremesh woven 0.63 mm dia aperture 1.18 mm , ptmt ball cock 15 mm complete , pvc towel rail 600 mm , glass corner shelf with grill , sliding door bolt alu 300 mm , ptmt flushing cistern 10 ltr cap , cp towel rail 600 mm , alu bow handle 150 mm , pvc towel rail 450 mm , helical door spring , ptmt jet spray with 1 mtr tube , paint synthetic enamel black , paint synthetic enamel white , bib cock cp 20mm , waste pipe pvc for whb 32mm , paint synthetic enamel yellow , pvc connection 15x600 with ptmt nut , alu lugs for 240 sqmm cable , alu lugs for 300 sqmm cable , alu lugs for 185 sqmm cable , alu lugs for 400 sqmm cable , alu lugs for 120 sqmm cable , alu lugs for 70 sqmm cable , alu lugs for 150 sqmm cable , alu lugs for 50 sqmm cable , alu lugs for 95 sqmm cable , alu lugs for 35 sqmm cable , desert cooler steel body cap 85 ltr //bid details 2 / 78

CTN :45590996 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For corrigendum : supply of hydraulically regulated door closers conforming to is 3564,bathroom or toilet mirror (v3),bathroom or toilet mirror (v3),ceramic ( vitreous china ) flushing cisterns for water closets and urinals conforming to is 774,ceramic ( vitreous china ) flushing cisterns for water closets and urinals conforming to is 774,rotational moulded polyethylene water storage tanks (v3) conforming to is 12701

CTN :45742664 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of rotational moulded polyethylene water storage tanks (v3) conforming to is 12701 (q3) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , towel rail (q3) , towel ring (q3) , led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , led luminaire (recessed luminaire) (ceiling light) conforming to is 10322 (part 5/section 2) (v4) (under bis scheme - ii) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , plastic bib taps, pillar taps, angle valves & stop valves for hot & cold water services conforming to is 9763 (q3) , led batten light (led tube light) (v2) (q2) , led bulkhead light (q3) , bathroom or toilet mirror (v3) (q4) , copper alloy taps/stop valves (v2) conforming to is 8931 (q3)

CTN :45739753 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of aluminium washer 20mm fuel tank washer , aluminium washer 22mm , clip shaft , clip d frame , split pin small , split pin medium , split pin large , apr repair kit , 70 kg reducer dia frame , air bottle valve , air bottle shim , air intake tube seal , delivery holder seal , clutch booster seal , 10 mm spring washer , 12 mm bolt 25 inch full thread with spring washer , 17 mm bolt 25inch