Get complete information related to latest Water Supply Schemes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Supply Schemes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Supply Schemes Tenders.
Tender For operation and maintenance - watersupplyschemes-annual maintenance 2025-2026 - leak rectification work of various distribution lines in kulakkada-pavithreswaram panchayath for the period of 12 months
Tender For watersupplyschemes-annual maintanance -2026-27-cwss to oachira,karunagappally,alappad and clappana.-rectification of leakages, blockages etc in the distribution line and transmission mains in oachira panchayath
Tender For watersupplyschemes-rwss to thekkumbhagam - annual maintenence 2026- 27-rectification of leakages, blockages etc. in ac/ pvc/ ci/ gi pipes of pumping main and distribution network in thekkumbhagam panchayath
Tender For watersupplyschemes-rwss to neendakara - annual maintenance 2026-27- rectification of leakages, blockages etc. in ac/ pvc/ ci/ gi pipes of pumping main and distribution network in neendakara panchayath.
Tender For corrigendum : price bid for supply, installation, testing & commissioning of automatic water sprinkler system as per attached boq to our mother dairy (unit: balaji dairy), tirupati on f.o.r basis. vendor must visit our mother dairy (unit: balaji dairy), tirupati before submission of price bid to understand bom/boq and actual scope of work. for any technical clarifications/queries, please contact mr. suresh (engineering department) @ 9966428314. a. the contractor shall coordinate implementation of his daily work activities, working hours, throughout the construction period with the client and the supervising engineer. b. the contractor shall make the necessary tools, electrical extension boards etc. to prevent interruption in work performance. c.the contractor shall take all necessary measures to protect and minimize environmental hazards including pollution, noise, dust etc . d. contactors are advised to visit the site before quote the offer to understand the site conditions. e. all tools & tackles, machinery, manpower or any kind of resource needed into the execution shall be vendor's responsibility and any cost on this part shall be deemed to be inclusive in item rates itself and no claim shall be accepted in this regard. f. safety is prime motive; contractor has to ensure all safety measures without any reasons. contactor will implement safe mode of working only. g. housekeeping of the site is contractor's responsibility, and it is to be ensured on daily basis. h. rate quoted shall be inclusive of all other heads like materials,labour, tools & tackles, plant & machinery and others. i. as quantities given are only indicative and can vary to any extent, therefore bidders are requested to quote justified rates even where quantities mentioned are small or rate only (r/o) is mentioned.
Tender For supply of item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall diameter (mm) /- 2.0 15 max. safe pulling tension lo
Tender For annual maintenance of various watersupplyschemes underphesd no. 1, nuh under phed, punhana comprehensive maintenance for 18 no. boosters and repair of pumping machinery, replacement of old gi lowering pipe, repair replacement of electrical items i.e. sta
Tender For supply of misc item d d - sink mixer , health faucet abs cp with cp tube , bathroom cabinate single mirror white colour , float valve , overhead bathroom shower abs , float valv , float valve , pvc cover for storage water tank pvc , bathroom cabinate double mirror white colour , pvc connection , pvc waste coupling , led bulkhead fitting in engineering plastic housing , led bulb , ferric alum , s s sliding door bolt , butt hinges , mcb double pole c series , mccb , mccb , submersible cable , looking mirror , wire mesh width , plywood six mm thick , rubber gasket , rubber mats for electrics purpose