Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high watertemperaturegauge, oil temperaturegauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply of set of 03 gauges along with probe and cable suitable for demu dpc 1400 hp with cummins kta 50l. fitted in panel instrument cil part no. 4055254 (gauge lube oil temperature : 3414455, gaugewatertemperature 3414454 , gauge lube oil pressure : 500109) . make : cummins/vdo/pricol or similar. [warranty period: 30 months after the date of delivery ]
Tender For corrigendum : procurement of spares for srgm system - item, rocking arm,lh, assy, rocking arm,rh, assy, pcb pio out 2j25, right nose clamp, support bushes sub-assy, lever, thermistor assy, gauge pressure, gauge,pressure, support sub assy, proximity switch, master gauge conn pipe fxtr w/nippl, pcb, elevation amplifier, pipe fitting sub, front feed buffer, rear feed buffer, hydraulic fluid, rng, bumper, hyd.fluid (mil-prf-5606), washer, grease, dod-l-25681d, lube oil, mil-l-16785a grade a, nut, self-locking, m8 uni 7473, lube oil, mil-l-6086d, grade l, midget flange lamp, o ring ms28775-0aa, o ring ms28775-132, hexagon socket head cap screw, cap, m8 1.25x25(pboh), nut self locking m12 uni 7473, o ring ms28775-220, diode jan 1n485b, bumper, lamp ms 18209-387, needle bearing, washer, 8.4 dia, o ring ms28778-8, o ring, bearing, rlr, dbl row, riv, circlip, 42 dia as per is:3075(2), circlip, 72 dia as per is:3075(2), packing jacottet 60434/packing jacottet 60434a, clamp assy, right nose, guide, bushing, split, washer, busher, bleeder valve, screw mm12x35, disk, damper, lamp, seal, o ring, screw, spring, compression, wire (one reel), o ring ms28775-215, dowel, headed, lampholder, screw, rd head, special, screw, special, spacer, muzzle cap, fuse f028250v3a, cartridge, filter, connector ms3450w14s-7s, drift pin dia 3/drift punch dia 3mm