Get complete information related to latest Watering Can Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Watering Can Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Watering Can Tenders.
Tender For supply various type construction material at gp. pilandri tal pauni dist bhandara - 80 mm. metal white-(hand broken metal) with royalty, 40 mm metal white- (hand broken metal) with royalty, 40 mm metal black- (crusher broken metal) with royalty, 20 mm metal black- (crusher broken metal) with royalty, 12 mm metal black-(crusher broken metal) with royalty, 6 mm metal black-(crusher broken metal) with royalty, boulders rubbles and masonary stones, sand river (unscreen) with royalty, sand (nallah bed), soft murum with royalty, hard murum with royalty, soil, cement 53 grade opc, cement 53 grade ppc, burnt bricks ( ii class), mild steel bars of various sizes, tmt steel bars of various sizes, oil paint isi mark, plastic emulsion paint, wall paint isi mark, centring tar, torpin oil, bitumen pack tin 60/70 at mumbai, murum carting only, weste material carting, mixter machine per day with desel and driver, water tanker with desel and driver, centring rent for drain work, centring rent for cement road, centring rent for building work, rcc pipe 1000 mm, rcc pipe 800 mm, rcc pipe 600 mm, rcc pipe 450 mm, rcc pipe 300 mm, compaction of earth work in embankment upto layer of 30cm comp machinary charges only, compaction of soft murum/ kankad 2.00 to 7.00 width (200mm loose) with static roller including necessary artificial watering etc complete, transporttion of soft murum on road side etc complete as per analysis, information board 1)size 1.20 x 0.90 , information board 2) size 0.75 x 0.90, transportation of excavated soil from ex-mat. tank to field up to 3km, wooden door frame size 6 * 3.25, cement door frame size 6*3.25, wooden door size 6 * 3.25, plywood door size 6 * 3.25, door kits per door, precost sheet, oil engine, meter stone, ferlong stone, jcb per hours, rollar per day with desel driver, griil work, murga, pavour block(gattu), quota tyles, vetryfied tyles, bt pod, wc pod, nutri trap, ms poor, ac sheet, gi sheet, distemper, birla white, in well boar 4.50 inch, in well boar 6.00 inch, epex ext. primer, epex ext. emulsion, epex interial emulsion, white putti, water tank (syntax), kadappa stone, nahani tap, fly ash brick(cement bricks), gi pipe 15 mm dia., gi pipe 20 mm dia., cpvc pipe 50 mm, cpvc pipe 25 mm, cpvc pipe 15 mm, water level indicator, lighting conductor, type coper patti, gi cd staire, pevor block (ruber quoted), pevor block color quoted, pvc lbow verious size, pvc t verious size, 25 mm pvc pipe, 250mm pvc pipe 6 kg, 250mm pvc pipe 4 kg, 200mm pvc pipe 6 kg, 200mm pvc pipe 4 kg, 110mm pvc pipe 6 kg, 110mm pvc pipe 4 kg, 90mm pvc pipe 6 kg, 90mm pvc pipe 4 kg, 75mm pvc pipe 6 kg, 75mm pvc pipe 4 kg, 63mm pvc pipe 6 kg, 63mm pvc pipe 4 kg, sluice valve 80 mm, sluice valve 125 mm, sluice valve 150 mm, sluice valve 200 mm, sluice valve 100 mm, air valve 50 mm, air valve 80 mm, air valve 50 mm, reflux valve 80 mm, gi pipe 80 mm, pvc special tee,bend,coupler,taispeace,pipe, gi special hang, nutbolt,rubber shocate, tee, bend, solution, 3 seater steel chaire, 3 seater rcc chaire, toilet sheet, pump 3 bhp 200 mm & 120 mm head, pump 5 bhp 200 mm & 120 mm head, gi bend 80 mm, gi coupller 80 mm, control panal box, steel angle, chaniling facing, primer, plywood sheet, ceramic tiles, handwash basin, tap, water meter, waterproof cement
Tender For supply of modified coach water inlet (connector) with strainer., as per drawing: camtech.m.coach watering-08-s with mdts-203 revision 06, packing instruction: pi042 ver1.0, as per standard packing. it should be ensured that item should not rub duringtransportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ] ]
Tender For engaging labour for pruning, weeding, soil tilling for application of fertilizers and pesticides, watering and plantation of avenue plants, whenever required, along gnt road (from rtc to welcome nellore) and podalkur road (from batwadipalem junction to dycus road), mini bypass (from ayyappagudi flyover to gpr kalyanamandapam), celebrations road for maintenance of central dividers along gnt road (from rtc to welcome nellore), podalkur road (from batwadipalem junction to dycus road), dargah dividers and traffic islands in nellore municipal corporation (rural).
Tender For sircarpalayam head works- operation and maintenance of chlorination plant, summer watering arrangements and arresting pipe leakage en-route at srpm water works in senior section engineer/works/b/ponmalai section for a period of twelve months.
Tender For corrigendum : providing of horticulture service - lumpsum based - general maintenance of garden/lawn/field/nursery/park, as per atc; planting trees/plants/grass, general maintenance of plant (mowing, strimming, laying, sweeping, watering, weeding), applying fertilizers, cleani..
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab