Get complete information related to latest Waterline Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Waterline Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Waterline Tenders.
Tender For providing painting and other repair works such as toilet renovation, water proofing, waterline, ugd line, railing, structural glazing, false ceiling and other developmental works at shanthinagar ttmc, bengaluru
Tender For scope of work (sow) as mentioned in tender and schedule of work( 34 )items as given below ,[1] reprg of cyl hyd pumps motr rllr of wap 150.000 set,[2] techlgl upkpmt of hyd+pneum systm of wap 90.000 set,[3] repr g.box dr.mech of convr.crn.chgr.mnp 90.000 set,[4] struc repg-fce convr chut chrgr crn+pipe 60.000 to,[5] maint. of manipulator cross rails 72.000 set,[6] maint. of manipulator long travel rails 72.000 set,[7] fab & chnging of gas lines of a & b fces 150.000 m,[8] fab,rep,chnging of diff size water lines 60.000 le,[9] clng of pipe trench and surrndng 60.000 le,[10] dismantlg,fab,erec 8in dia headers 198.000 m,[11] dismanlg,fab,erec of diff dia brnch line 147.000 m,[12] rep water filtrn unit of compr waterline 30.000 le,[13] servg/chng gate v/v of diff sizes 90.000 ea,[14] disman,lid,table,lid 30.000 set,[15] repair,str frame 24.000 to,[16] clean&overhaul,mech parts 24.000 set,[17] svce speed change,g/box 108.000 set,[18] replcg,locking lever assy 108.000 set,[19] clng,blade tensioning guide area 96.000 set,[20] remove,incoming&og roller tables 96.000 set,[21] svcg,pusher mechanism 90.000 ea,[22] svcg,swing hyd cyl,6set 54.000 ea,[23] svcg,hyd cyl,6nos 54.000 ea,[24] svcg,front vice operating hyd cyl 54.000 ea,[25] up keepg,floor area 3600.000 m2,[26] rprg,damaged coolant pipeline 1950.000 ft,[27] svcg,rotating roller table g/box 54.000 ea,[28] rprg,roller side guard&floor plate,fixg 36.000 to,[29] svcg,pwr pack 36.000 set,[30] svcg,gravity roller conv after weigh m/c 18.000 set,[31] clng,coolant tank&vice bed every week 54.000 set,[32] svcg,pneumatic line&vlv 54.000 set,[33] fab,str etc f/stacking matl 12.000 to,[34] replcg,lt driving&non-driving wheel assy 36.000 ea
Tender For regular operation and maintenance of water supply scheme with material at industrial area, residential colony and commercial complex jhunjhunu phase-i and ii - item rate, regular operation of tube wells installed with pumping machineries with round the clock monitoring, including complete repair and maintenance of pump set with cost of material and labour required for repairing/rewinding, lowering and un-lowering etc.the scope of work also includes repair and maintenance of panel board, main switches, kit-kates, electric connections, service cableand submersible cables inclusive of cost of material and labour required for uninterrupted functioning of tube wells.it is also inclusive of complete repair and maintenance of pipes connected with pump and motor, its replacement, if required, regular upkeeping of log book etc. and other works as mentioned in tender document / scope of work complete in all respect and as directed by engineer in-charge., regular operation and maintenance of pump houses located at wss complex/complexes.the work includes operation of distribution line main valves for daily supply of water of the industrial area at supply times specified by corporation. regular operation of pump house installed with existing centrifugal / monoblock pump / motors, with round the clock monitoring, including complete repair and maintenance of pump sets, connecting suction/delivery pipes jointing material, panel, main switches, kit-kates, electric connections, service cable including cost of material and labour required for repairing / rewinding, removal and replacement etc. for uninterrupted functioning of electric panels and pump sets with regular up-keepment of log books, repair of leakages in pump glans and ms/ci/ac pipeline system inside of wss campus complete, regular chemical dosing in cwr maintaining general cleanliness at pump house and wss campus complete in all respect as directed by engineer in-charge., repair & maintenance of existing distribution / rising main pipe line system consisting of ac pressure pipeline /pvc/upvc/hdpe/ci/ di lines for maintaining smooth water supply in area covered under the scope of work.the scope of work includes timely repairing of leakage in all existing distribution / rising main pipeline of all sizes by digging out suitable size of pit in soft & loose soil / hard soil including cutting of bituminous / cement concrete / wbm / wmm surface at any site of work at no extra cost.it is also inclusive of cutting of pipe ends, fixing of pipe pieces with jointing material to make repair leak proof and refilling the pit / trench by excavated soil by ramming it at all sides of pipes & upto ground level. contractor will do dewatering at his own level by making necessary arrangements, if required. contractor will usetheir own t&p and jointing materials, however the pipe line and sluice valves (if required) etc. shall be provided by the corporation but the contractor shall have to deposit the damaged material in riico store. but no additional payment shall be made on account of any material or transportation charges.
Tender For tender for supply of fixing self regulating heat tape cable insulation and accessories in ppr pipe - providing and fixing self regulating heat tape resistance heating cable suitable to protect freezing of water in pipelines having rated output of 35 w per meter at 220 v ac supply the heating cable shall have capabibility to automatically adjust its heat output based on surrounding temperature conditions to prevent freezing and overheating the cable should be suitable for continuous operation in outdoor in adverse climatic conditions flexible for installation around pipelines joints and valves and compatible with temperature controller systems , providing m20 3 pin connector suitable for making secure electrical joints between self regulating heat cable terminals designed for reliable power and signal continuity the connector should be operable for operation at rated 220 v ac supply and compatible with heating cables of specified capacity must l ensure safe and firm termination with robust insulation to prevent moisture ingress short circuits and electrical leakage the connector shall be made up from high-quality weather resistant materials suitable for continuous outdoor operation under adverse environmental conditions it should be ease in installation with a compact and durable design for use in pipeline joints terminations and interconnections the connector should be compatible with temperature control systems and associated accessories ensuring long term performance safety and protection against overheating corrosion and mechanical stress , providing temperature differential controller with auto and manual operation housed in a robust ip65 rated enclosure suitable for controlling heat tracing systems to prevent freezing of water in pipelines and utilities the controller should be capable to automatically switch the heat tape on off based on preset temperature differentials ensuring optimal performance and energy efficiency the controller should have in built safety features such as overrun protection and burn out protection to safeguard the heating cable and associated equipment from damage the enclosure shall be weatherproof and suitable for outdoor installation offering protection against dust and water ingress and ensuring reliable long term operation under harsh environmental conditions , providing pt100 temperature sensors with 10 metre cable suitable for accurate temperature measurement and control in heat tracing and pipeline monitoring applications the sensors should be made up of platinum resistance type pt100 ensuring high precision stability and reliability over a wide temperature range the wire with sensor should have high quality insulation suitable for reliable signal transmission and compatible with temperature controllers and monitoring systems the cable shall be durable flexible and suitable for installation in outdoor under extreame weather conditions in high altitude area , providing 3 core 1.5 sq mm pvc insulated and pvc round sheathed multicore flexible cable comprising bright annealed bare copper conductors suitable for heavy duty industrial applications rated for voltage grade up to 1100 volts the cable shall confirm to requirements of is 694 2010 the conductors shall be made of high-conductivity annealed copper ensuring efficient current carrying capacity and minimal losses each core shall be uniformly insulated with high-quality pvc compound and the overall cable shall be protected with a durable pvc outer sheath providing resistance against moisture abrasion and mechanical stresses the cable shall be flexible in nature allowing ease of installation in confined and complex routing conditions it should be suitable for continuous operation in indoor and outdoor adverse environments offering reliable performance electrical safety and long service life
Tender For to repair with spare for vehicle no.gj06g-2609. - ac flooring coil assembly , ac filter , work of removing the steering and dashboard and wiring of the vehicle, removing the ac blower, removing the cooling coil, and fitting a new cooling coil. , work of checking the ac pipeline leakage of the vehicle, charging the ac gas and completing the ac. , work of providing water service and greasing to the vehicle.
Tender For to repair with spare for vehicle no. gj06ga-4500. - ac filter, open the steering wheel and dashboard and wiring of the vehicle, open the ac blower, if there is leakage in the front floor coil, open the cooling coil, repair it and fit the cooling coil., open the rear cooling coil of the vehicle, service it and fit the cooling coil., check the ac pipeline leakage of the vehicle, charge the ac gas and complete the ac., provide water service and greasing to the vehicle.
Tender For bakali estimate for providing/replacement of existing old/damaged ac/pvc pipeline to di pipeline in village bakali distt kurukshetra. estimate for providing and installing 2 nos tubewell with complete pumping machinary against failed in village bir kalwa and kanipla, distt. kurukshetra and all other works contingent thereto.
Tender For corrigendum : replacement of ac pipeline by hdpe pipeline (90 mm dia) at egara jemari colony ,diversion of 80 mm dia ac pipeline and laying hdpe pipeline (90 mm dia) near tmc party office egara and allied works at belabathan and jemari and amritnagar h/w site unde - replacement of ac pipeline by hdpe pipeline (90 mm dia) at egara jemari colony ,diversion of 80 mm dia ac pipeline and laying hdpe pipeline (90 mm dia) near tmc party office egara and allied works at belabathan and jemari and amritnagar h/w site under rcfa division-i phe dte. (sl no. 65)