Tender For supplying and fixing of electrical fitments for newly constructed toilet of d coy barrack and new jamin toilet at stc bsf of north bengal electrical installation - wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required. group b, rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. group b, wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire., wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.2 x 4 sq. mm + 1 x 4 sq. mm earth wire. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire., supplying and fixing 3 pin 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required. 3 pin 5 amp, supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. size : 180mm x 100mm x 60mm deep., supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator). 8 way , double door., supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c"curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole., supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c"curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole and neutralsingle pole and neutral., earthing with g.i. earth pipe of following size including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 4.5 metre long, 40 mm dia ., supplying and laying following size g.i. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with gi thimble etc. as required.6 swg., supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. standard make., add applicable rate of gst @18% in place of 12% (0.0633mf) on dsr item. s no.(1 to 12), add 1% labour cess on s no. (1 to 12) + s no.13, modified estimate cost after using correction factor on account of gst @ 0.973 on dsr items s no. (1 to 12) + s no.13 + s no.14, supplying and fixing 3 mm thick phenolic laminated sheet cover in front of ms switch box including making hole and al. alloy/ cadmium plated iron screws, 20 mm, washers etc. as required.hylem/formica/anchor/as approved by engg incharge., supplying and fixing of 6 watt surface type trim cosmo panel square shape led light suitable for 240 volt, single phase, 50
Tender For tender for supply of 33kv line maintenance between jaduguda and narwapahar for two years : : - replacement of 33kv pin insulator including supply of necessary fixing materials. this includes binding of acsr dog conductor also , replacement of 33kv disc insulator including supply of necessary fixing materials in existing 33kv line , replacement of 33kv cross arm including supply of necessary fixing materials , replacement of packing pieces in existing cross arms , replacement of pg clamp for dog conductor including supply of necessary fixing materials , installation of complete stay set including supply of necessary fixing materials. this includes digging of stay pits and grouting of stay rod in cement concrete foundation also as required , installation of gi wire 7/10 swg for stay including supply of necessary fixing materials , installation of gi wire 8 swg for guard wire , installation of gi wire 7/14 swg for earth wire including supply of necessary fixing materials , replacement of back clamp for cross arm & top bracket (50mm x 10mm flat) including supply of necessary fixing materials , installation of d.p. channel (100mm x 50mm x 6mm) 1 x 3 mtrs including supply of necessary fixing materials , installation of d.p. channel support clamps including supply of necessary fixing materials , replacement of earth clamps for earth wire including supply of necessary fixing materials , replacement of side stay clamp including supply of necessary fixing materials , replacement of angle stay clamp including supply of necessary fixing materials , replacement of cross bracing for d.p. structure including supply of necessary fixing materials , replacement of clamp for x-bracing including supply of necessary fixing materials , installation of earthing pit using pipe earth electrode as per drawing including connection to earth wires and supply of necessary materials required it , laying & tensioning of acsr dog conductor including fixing / binding at insulators in the 33kv line (per km consist 3 conductor of ryb phases). , tensioning of dog conductor and supporting & fixing on insulators including binding as required in the section (per km consist 3 conductor of ryb phases). , cutting and removal of hages , trimming of trees and branches of size more than 4inch dia and disposal of un-serviceable materials to ucil canteen building as per direction of eic , cutting and clearing jungle grass including uprooting of rank kegetation , long grass , bush wood , trees and saplings upto 4inch dia measured at a height of 1 meter above ground level as per direction of eic , erection of m.s. rail pole 105 lbs , 13 meters long including drilling of 2 nos holes of 5/8inch dia as required at one end of rail pole for fixing of f- clamps , installation of ab switch on double pole structure. this includes fixing of required channels and clamps and other fixing as required and for proper operation. this includes connection of dog conductor alsodog conductor also , installation of 33kv lighting arrestor on double pole completed with line and earth connections , maintenance of ab switch on double pole structure , 33kv line patrolling from narwapahar to jaduguda , replacement of earth spike along the 33kv line & connection to pole , number of rail pole with painting of pole upto 6 feet height for colour coding of line
Tender For supply of procurement of steel electrode and cutting gouging electrode : : 5 =5 = - electrode gouging 17,4mm as per is 8987- 1978 , electrode a5.15,ci,4mm,mchnbl as per is 814- 2004 , electrode e7018,5mm weldalloy lh as per is 814 - 2004 , electrode ss,e312,4mm as per is 814 - 2004 , electrode mn stl,4mm,450mm,mn 14.5per as per is 814 - 2004 , electrode e6013,ms,3.15mm,450mm,medm ctd as per is 814 - 2004 , electrode 4mm f-joining disimilar as per is 814 - 2004