Get complete information related to latest Wet Disintegrator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wet Disintegrator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wet Disintegrator Tenders.
Tender For supply of supply of rishabh make meters and transducers d d -1. supply of voltmeter model rish eine nx input - 100- 500 v l-l -programmable-, 3ph 3w by 4w network, accuracy class - 1. 0, , 2. supply of current meter model rish eine nx ,input 1a by 5a -programmable-, 3ph 3w by 4w network, class - 1. 0, , 3. supply of current meter - model rish vdc c with shunt , input - 0 - 75 mv, display - 14 mm led display, accuracy class - 0. 1, , 4. supply of voltmeter model rish eine plus , input - 0-500 v, accuracy class - 0. 5, , aux 2060vdc , 5. supply of ammeter model rish eine plus with shunt, input - 0 - 75mv , 6. supply of powerful dc signal isolator model si101,dc isolator 1 input,1 output, input - 075mv dc , 7. supply of ammeter model rish eine nx input1 by 5a programmable, 1 phase network accuracy class -1 4 digit, , 8. supply of voltmeter model rish eine nx input 57. 8 - 480v l-n programmable, 1 phase network, accuracy class - 1. 0, , 9. supply of voltmeter model rish vdc c input - 0-75mv, display - 14 mm led display , accuracy class 0. 1 , , 1. supply of voltage transducer model tv 808, type dc isolator 1 input-1 output - e8 housing- input 0-400 v dc output - dc voltage - 0-5v , 11. supply of ammeter model rish eine plus input -0-75mv, accuracy class - 0. 5 , aux 40-300vac by dc, without shunt , 12. supply of current transducer model rish con i , input - 1-5a , 13. supply of current transducer model tv 808 ,type - dc signal isolator 1 input-1 output - e8 housing- input - 0-350 v dc, output -dc voltage - 0-5v , 14. supply of current transducer si101, type - dc signal isolator 1 input-1 output input - 0-75mv , output -dc voltage - 0-5v , 15. supply of voltmeter model eq 91, cl 1 , analog voltmeter scale -0-500 v-, 90degree, 96mm x 96mm , 16. supply of voltmeter model eq 91, cl 1 , analog voltmeter scale -0-300 v-, 90degree, 96mm x 96mm , 17. supply of ammeter model eq 91, cl 1. 0 ,ct operated, scale -0-200 a- ctr 200 by 5 amp , 18. supply of ammeter model pq 91 with shunt 150a by 75mv, cl 1. 0 ,90 degree, scale -0-150 a , 19. supply of current meter model vl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-25 a-, ctr, 25 by 5 amp , 20. supply of voltmeter model vl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-500vac- , 21. supply of dc voltmeter meter model pl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-100vdc- , 22. supply of current meter model vl 91 , 23. supply of current meter model vl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-150 a-, ctr, 150 by 5 amp , 24. supply of dc voltmeter meter model pl 91 ,cl 1. 0, 96x96 mm , scale 240 degree -0-400vdc- , 25. supply of ammeter model rish eine plus with shunt 1200a by 75mv, input - 0 -75mv, , 26. supply of voltmeter model pq 91, input - 4-20ma, size 96mm x 96mm, class 1. 5, 90 degree
Tender For empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For corrigendum : tender for supply of clip on type terminal station , auto change over switch 250a , cam type single pole on-off switch 10amps , 1s160 , triple pole moulded case circuit breaker 100amps , hcos 100a for emergency operation(ex.)if envisaged in sotr , illuminated push button green , cam type selector switch 2p 2 way with off 10a , hrc fuse link rated 100a , fuse link 2amps , helo starting cable with nato end connectors (21 meters) , mccb 630a , type lm 630b , make e , 3 pole mccb 32a -nsx100f , mcb 250a with micrologic 2.2 trip unit(lv431770) , tp mccb rated 50a , single pole nine way without off rotary switch rated 16a , contactor 110a t.p.(contact kit) , aux contact.base block ( 1 no+1nc) for 110-a t.p. , fuse 32a fitting hrc , unshourded pushbutton 1no+1nc with yellow colour lens(pmt1ab , illuminated pushbutton integral led 230v red , add on 1no contact , d.p miniature circuit breaker rated 16a , terminal , conventional fire detection panel 4 zones , on delay electronic timer ac 110-240v having range 1-30s , 230v ac relays 4 c/o with led and base alonwith clamp , tp mcb 63a(c60h 3p 63a c) , ammeter 0-1000a , rm-800a , ctr 1000/5a , 96x96 cl1 acc 900 scale , hrc fuse fittings rated 20a (3nw20nnsf) , hrc fuse link rated 6a(3nwns6) , hrc fuse fitting rated 20a (3nwns10) , insulation monitoring relay 115v 3ph 400hz (vtv-02) , ammeter 0-200a ctr 200-5a , 400hz acc cl-1 , 96x96 rm at 150a , kilowatt meter 120-0-750 kw size 96x96mm , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , 1 watt , 24v dc/ac , led bulb , milky white of e27 thread type , 1 watt , 230v ac , led bulb , milky white , of e27 thread type. , breaker 25a , dp mcb , step down transformer 20kva , 380 230v , 3ph , 50 hz star-delta , smoke detector tester gas bottle - solo , main processor unit , navigation lamp 65w 230v (per yard) , under voltage coil 230 , 50/60 hz , hrc fuse fitting with fuse link rated 4amps , hrc fuse fitting with fuse link rated 2a , 3 pole mccb , 100amps , 36ka , schinder make , phase sequence indicator 50-500v , 96x96mm cl1 acc 900 scale , kw mtr 15-0-150kw , ctr 2005/5a , rm at 80kw , 415v , 3p , 2 ele 96mm , generator protection unit415v , 3ph , 50hz , load sharing unit mv av 380v , 50hz , 3ph , ctr 250 5a , m340-discrete outputs-modicon m340 discrete dc output , indicating lamp integral led white colour , 24v ac/dc , indicating lamp integral led green colour , 24v ac/dc , indicating lamp integral led green colour 230v , contactor 800a dc , 28v coil with 1no/1nc aux. contact
Tender For supply of pvdg metering arrangement for tariff conversion from commercial to industrial at cto compound ngp : : -sitc of wall mounted mv panel having 1 no 250 a 4 pole mccb as incomer and 2 nos 125 a and 1 no 160 a 4 pole mccbs for outgoings , supply and installation of 1 no trivector energy meter class 0. 5s model er300p base mounting , laying and fixing of one number above 95 sq. mm and upto 185 sq. mm size cable in the existing masonry open duct , laying and fixing of one number above 95 sq. mm and upto 185 sq. mm size cable on wall surface , p and f 6 swg dia gi wire along with existing surface or recessed conduit or submain wiring or cable , charges for shifting of existing lt cable from old panel to the new panel