Web Analytics Made Easy - StatCounter

Window Air Conditioner Tenders

Get complete information related to latest Window Air Conditioner Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Window Air Conditioner Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Window Air Conditioner Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45713858 Due date: 18 Jul, 202618 Jul, 2026 25.00 Lacs
Tender For repair maintenance of various types of summer appliances and other connected items at af station jammu and kaluchak under ge (af) jammu - repair to split ac and window ac, supply of labour only for attending and rectification of daily complaints for day to day maintenance and servicing for split ac/window ac /hot & cold air conditioner/dual inverter air conditioners/flame proof ac of any capacity and make installed in various locations of 23 wing af jammu and 256 su kaluchak (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition within 24 hours for minor faults and within 48 hours for major faults all as specified and direted by engineer in charge.note: (a) contractor has to employ highly skilld refrigerator mechanic with helper and necessary t&p for attending day to day complaints of ref and ac failing which recovery shall be made at two times of quoted rate. (b) rate quoted shall be inclusive of transport from af station to work shop & back shifting within permises.( c) any parts shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. , m&l for shifting of split type ac/ window type ac capacity upto 2 ton , including submain/point wiring all electrical items and drilling, making good on surface of pcc concreting, white cement plastering and all necessary items and transporting complete one location to other location in 23 wing area and 256 su kaluchak area replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by engineer-in-charge., supply only the following items to incorporate against repairable summer appliances window / split type acs against relevant items no 2.00 and 3.00 here-in- before: -, blower motor complete suitable for window type ac upto 2.0 ton all as specified and directed by engr-in-charge., indicator suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., thermostat switch suitable for window type ac up to 2 tonall as specified and direted by engineer in charge., control knob suitable for thermostat switch and selector switch of window type ac up to 2 tonall as specified and direted by engineer in charge., selector switch suitable for window type ac up to 2 ton all as specified and direted by engineer in charge., relay along with box suitable for window type ac upto 2 ton all as specified and direted by engineer in charge., plastic air filter suitable for window ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., outer unit condenser fan motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., fan for outer unit condenser motor suitable for window type ac up to 2 ton. make- voltas/ bluestar/ lg/ samsung/ as on site., front grill as per existing suitable for window type ac upto 2 ton.make- voltas/ bluestar/ lg/ samsung/ as on site., plastic air filter suitable for split ac indoor unit ac upto 2 tr. make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for window type /split ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac indoor unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., s&f power control board ( pcb ) for split ac out door unit dual inverter/hot and cold ac up to 2 ton . make- voltas/ bluestar/ lg/ samsung/ as on site., wiring kit suitable for split ac and window type ac upto 2 ton., condenser fan motor complete with fan suitable for out door unit of split type air conditioner upto 2 ton. make- voltas/ bluestar/ lg/ samsung/ as

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45739153 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For providing of repair and overhauling service - window air conditioner including green ac (dfm); voltas; yes; buyer premises

CTN :45739484 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For supply of window air conditioner 1 point 5 ton , stabilizer , drainage pipe , installation , window air conditioner stand

CTN :45720849 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)

CTN :45712234 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For providing of repair and overhauling service - window air conditioner including green ac (dfm); daikin; yes; buyer premises,repair and overhauling service - split air conditioner including green ac (dfm); daikin; yes; buyer premises

CTN :45587237 Due date: 30 Jun, 202630 Jun, 2026 NA
Tender For bid to ras providing of repair and overhauling service - window air conditioner including green ac; voltas; yes; buyer premises

CTN :45494104 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For corrigendum : supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , drinking water coolers (v4) isi marked to is 1475 (q2) , household refrigerating appliances as per is 17550 (q2) , ceiling fan complete with blades 6.00 bee , exhaust fan steel body 230v , air circulator fan noise level 100-120 db , window air conditioner , voltage stablizer , water heater storage type steel body with ss inner tank 2 kw , desert electric cooler steel body 20 gauge gi sheet , ceiling fans complete with blades down rods electronic regulator and accessories 230 v , exhaust fan steel body ac , exhaust fan steel body ac , turbo heavy duty metal body exhaust fan flame proof , pedestal fans 450 or 400 mm sweep 1350 rpm , wall mounted fans 400 mm 1350 rpm , air circulator fans steel body * /bid number : gem/2026/b/7559716 + /dated: 09-06-2026 ' ' / bid document 1 / 24

CTN :45697944 Due date: 13 Jul, 202613 Jul, 2026 75.00 Lacs
Tender For supply of pn or zener diode or led characteristics apparatus , verification of kcl and kvl , resistance in series and parallel apparatus , ohms law apparatus without power supply , ohms law apparatus with aluminum panel 2 digital panel meters and power supply , transistor characteristics apparatus , fet characteristics apparatus , half wave full wave and bridge rectifier apparatus , ripple factor apparatus , digital logic trainer , verification of truth table of logic gates using universal gates , flip flops using nand gates and ttl ics , four bit counters synchronous and asynchronous , four bit shift registers , encoder or multiplexer eight to one line , decoder or demultiplexer one to eight line , four bit analog to digital convertor , four bit digital to analog convertor , light intensity or phase control using scr or triac , scr commutation techniques , switching action of a bjt , single phase half wave full wave and fully controlled bridge rectifier or convertor using scrs , three phase half controlled bridge converter with r and rl load , three phase fully controlled bridge converter with r and rl load , single phase cycloconverter , instrumentation trainer using transducers , burdon tube pressure gauge trainer kit , strain gauge trainer kit with cantilever beam , lvdt trainer kit , speed measurement using photo electric and magnetic sensors , temperature sensors kit , measurement of water level using strain gauge , measurement of water level using capacitance transducer , ac servo speed torque characteristic trainer , dc servo motor speed torque characteristics trainer , stepper motor controller trainer , analog lab trainer bread board model , digital lab trainer bread board model , plc trainer , transmission line trainer abcd t and pi parameters ferranti effect load test , idmt over current relay testing kit electromechanical type , buchholz relay testing kit with compressor and oil , over voltage relay testing kit electromechanical type , over current and earth fault relay testing kit three phase static type , over current relay testing kit static type , measurement of power and power factor single phase and three phase , to study a typical bhk house wiring , four to one multiplexer and one to four demultiplexer , vapour compression refrigeration vcr test rig , water cooler setup , air conditioning test rig , domestic refrigerator , window air conditioner , split air conditioner , air cooler evaporative , tube cutter , pipe bender , flaring and swaging tool kit , reamer , brazing torch , manifold gauge set , vacuum pump , refrigerant recovery unit , refrigerant charging cylinder or electronic charging scale , refrigerant leak detector , digital clamp meter , digital thermometer , anemometer , tachometer , insulation material , refrigerants , recovery cylinders , weighing machine , electrical control panel , work benches , safety equipment
 Loading, Please wait...

Connect us via What's Up