Get complete information related to latest Wiper Motor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wiper Motor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wiper Motor Tenders.
Tender For corrigendum : supply, installation and commissioning of electrically operated set of wind screen wiper assembly complete with wipermotor, wiper arm with blade & pipe connections & water spray wind screen washing system including connections/tube & fittings completefor 3 phase locomotives as per plw's frs no. plw/ldo/loco/e wiper-002 rev. 0 to drawing no. 1209-08.130-511, alt. 1, drawing no. 1209-08.130 263 alt. 3 and drawing no. 1209-08.130-019 alt. 1. note: scope of supply as per clause 3 of plw's frs no. plw/ldo/loco/e wiper-002 rev.0. [warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] [ rate of supply 11 units per month , commencement time allowed -2 month ]
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For scope of work (sow) as mentioned in tender and schedule of work( 46 )items as given below ,[1] remvg 1hp,400v,3ph,50hz,1500rpm motor 4.000 ea,[2] remvg 3hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[3] remvg 5hp,400v,3ph,50hz,1500rpm motor 4.000 ea,[4] remvg 7.5hp,400v,3ph,50hz,1500rpm motor 4.000 ea,[5] remvg 10hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[6] remvg 15hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[7] remvg 20hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[8] remvg 30hp,400v,3ph,50hz,1500rpm motor 1.000 ea,[9] remvg 40hp,400v,3ph,50hz,1500rpm motor 2.000 ea,[10] remvg 60hp,400v,3ph,50hz,1500rpm motor 1.000 ea,[11] remvg 70hp,400v,3ph,50hz,1500rpm motor 1.000 ea,[12] remvg 1hp,400v motor,party to dispose 6.000 ea,[13] remvg 3hp,400v motor,party to dispose 2.000 ea,[14] remvg 5hp,400v motor,party to dispose 4.000 ea,[15] remvg 7.5hp,400v motor,party to dispose 4.000 ea,[16] remvg 10hp,400v motor,party to dispose 2.000 ea,[17] remvg 15hp,400v motor,party to dispose 3.000 ea,[18] remvg 20hp,400v motor,party to dispose 3.000 ea,[19] remvg 30hp,400v motor,party to dispose 1.000 ea,[20] remvg 40hp,400v motor,party to dispose 2.000 ea,[21] remvg 60hp,400v motor,party to dispose 2.000 ea,[22] remvg 70hp,400v motor,party to dispose 1.000 ea,[23] supply of motor bearing,1 hp motor 8.000 ea,[24] supply of motor bearing,3 hp motor 2.000 ea,[25] supply of motor bearing,5 hp motor 8.000 ea,[26] supply of motor bearing,7.5 hp motor 5.000 ea,[27] supply of motor bearing,10 hp motor 2.000 ea,[28] supply of motor bearing,15 hp motor 2.000 ea,[29] supply of motor bearing,20 hp motor 2.000 ea,[30] supply of motor bearing,30 hp motor 2.000 ea,[31] supply of motor bearing,40 hp motor 2.000 ea,[32] supply of motor bearing,60 hp motor 2.000 ea,[33] supply motor bearing,70hp/15hp vertical 3.000 ea,[34] supply&replcg of motor terminal block 15.000 ea,[35] testg nonwrking motor,various capacity 15.000 ea,[36] disconnect&remvg defective motor starter 15.000 ea,[37] reprg burnt/damaged motor stator lead 25.000 ea,[38] remvg faulty portion of motor main cable 16.000 ea,[39] layg of cable on wall/surface as per eic 95.000 m,[40] layg cable thr'rcc/hume/gi/open trench 45.000 m,[41] layg cable thr'excav underground trench 45.000 m,[42] disconnection of cable 6mm2 to 16mm2 10.000 set,[43] disconnection of cable 25mm2 to 70mm2 10.000 set,[44] cleang & paintg of motor 1hp5hp 16.000 ea,[45] cleang & paintg of motor 7.5hp20hp 10.000 ea,[46] cleang & paintg of motor 30hp70hp 6.000 ea