Get complete information related to latest Wire Brush Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wire Brush Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wire Brush Tenders.
Tender For supply, installation & commissioning of wirebrush cleaning machineelectrically operated static arrangement for cleaning of three type bogie bolster spring springs of casnub bogie for wagons. (technical requirement as per annexure "a" & "b") firm offered make ? varadom or equivalent. [ warranty period: 36 months after the date of delivery ] ]
Tender For deburring brush of armature commutator mica under cutting for hyt mica under cutting machine as per drg.no.3tms/cnb/drg/2005/4 alt-1. [deburring & polishing wheel (standard type) for tm armature with standard wire dia. abrasive nylon bristles coated with silicon carbide; od-200mm, thick-20mm, bore-35mm x pcd 49.5 x 7mm, 04 screw holes for holding with spindle of deburring wheel.] note: -one sample to be got approved before effecting bulk supply. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of various consumable & routine maintenance items for unit 1, 2 & 3 stage: i at wtps - teflon tape : size 1/2" width x 12mtr long, m seal fast curing epoxy compound, each packet contains 50 grams of resin base and 50 grams of hardener ( 1 kg box contains 10 packets)., hss hacksaw blade,size-1/2"bx12"lx0.025"thx18tpi., wirebrush with wooden handle size 50x150x300 mm, hiffin diamond lapping compound hi finator grade 14-05-30 ( in plastic injection ; per injection 5gm), rustolene 500 ml/tin, holdtite liquid joint compound[500gms/pkg]4565250014, chrome leather hand gloves for welder. size: 16 inch (400 mm), metal set putty, bearing retainer, epoxy based fast curing cold metal repair compound., oil stop leak putty 114 gms. pack, descaler [biodegradable water scale cleaner], pen oil - (500 ml/tin) heavy duty rust penetrator, molykote 1000 (1kg/tin), rust removing spray wd-40 in aersole packing of high pressure valves ., h577 pipe sealant ( per tube 50 ml ), instant flange sealant & gasketing compund h510/510, molykote 1000 spray can (400ml/270gms/can), grinding disc (wheel) size 100x4x16 mm, mos 13750 high cut (a.36) ., resinoid cutting off wheel size 350x25.4x3 mm, a24 ., wel.lead glass black, white plain glass for welders hand screen, esab/iol make gas heating torch, oxygen gas hose pipe blue 08 mm, make esab/dura., acetylene gas hose pipe red 08 mm, make esab/dura., two stage two gauge oxygen gas pressure regulator - model no : dura 0-10 - esab make, two stage two gauge acetylene gas pressure regulator model : dura a-1.5 - esab make, wirebrush size 12" with wooden handle, cutting nozzle size 3/64", cutting nozzle size 1/16", carborandum make emery cloth roll medium iss: 50-60 size: 50 mtrx25 mm, carborandum make emery cloth roll fine iss: 80-100, size: 50 mtrx25 mm, brand emery paper smooth fine size size 280 x 220 mm, flash back arrestor for cutting torch end mounted oxygen ., flash back arrestor for cutting torch end mounted da ., flash back arrestor for regulator mounted da cylinder., flash back arrestor for regulator mounted oxygen cylinder., gas cutting nozzles (1/32"), filler gauge set of 26 blades in mm 6" long, welding helmet, welding hand gloves leather size 14" for welding assly., welding cable copper conductor having single core high conductivity, suitable for 600 amp. of quality 70 sq.mm 999/0.3 mm as per is-9857/1990 vir insulated., hand screen armour, adhesive hylomer universal blue [100 gms/pkg/nos], pvc tap roll, oil paper size 2 x 2 x 1 mm thk, pvc hand gloves acid/alkali proof, hand gloves for heat resistance up to 350 deg. celsius: hand gloves with constructed from 100 percentage kevlar para-armid fiber with a cotton liner, size 10 (400mm). heat resistance for up to 350 deg. celsius temperature., blue matching tube camel student oil colour shade ultrasonic black-663 (in 20 ml tube), teflon tape : size 1/2" width x 12mtr long, m seal fast curing epoxy compound, each packet contains 50 grams of resin base and 50 grams of hardener ( 1 kg box contains 10 packets)., hss hacksaw blade,size-1/2"bx12"lx0.025"thx18tpi., wirebrush with wooden handle size 50x150x300 mm, hiffin diamond lapping compound hi finator grade 14-05-30 ( in plastic injection ; per injection 5gm), rustolene 500 ml/tin, holdtite liquid joint compound[500gms/pkg]4565250014, chrome leather hand gloves for welder. size: 16 inch (400 mm), metal set putty, bearing retainer, epoxy based fast curing cold metal repair compound., oil stop leak putty 114 gms. pack, descaler [biodegradable water scale cleaner], pen oil - (500 ml/tin) heavy duty rust penetrator, molykote 1000 (1kg/tin), rust removing spray wd-40 in aersole packing of high pressure valves ., h577 pipe sealant ( per tube 50 ml ), instant flange sealant & gasketing compund h510/510, molykote 1000 spray can (400ml/270gms/can), grinding disc (wheel) size 100x4x16 mm, mos 13750 high cut (a.36) ., resinoid cutting off wheel size 350x25.4x3 mm, a24 ., wel.lead glass black, whi
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif
Tender For periodical services and other connected items at af stn 3 wing under aor of ge (af) faridabad - demolition/dismantling of brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed ., m&l for brickwork with subclass b bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed ., all as per item no 02 above but except bricks., m&l for brick work with sub class b bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete all as directed., taking down cement plaster of any description on concrete surfaces such as soffit of rcc slab, chajjas and brick walls, ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed, m&l for rendering 15 mm thick cement plaster in cm 1:6 on brick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed ., m&l for rendering 15mm thick in cm 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl wpc as per user manual complete all as specified and directed., m&l for rendering 10mm thick in cm 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. ., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed ., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed ., m&l for rough cast (grit) finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed ., m&l for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed ., m&l preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white/tinted over a coat of appropirate primer over including a layer 2 mm acrylic wall putty to achieve desired smoothness and eveness complete by hand roller complete all as specified and directed ., m&l for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed ., m&l for preparation of newly plastered surface of walls & material & labour for applying two or more coats of 100% premium acrylic emulsion paint having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed ., m&l for complete removal of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wirebrushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, filling cracks with wall care putty etc and applying two coat of white wash complete all as specified and directed ., m&l for complete removal of old decorated, plast