Get complete information related to latest Wire Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wire Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wire Laying Tenders.
Tender For supplying and laying of under ground aluminium conductor xlpe power cable against damage main power cable and providing and fixing of ceiling fans and wall bracket fan in mp hall at govt. sarvodaya bal vidyalaya nctd jonapur delhi- 110047.
Tender For corrigendum : supply of sf 11 kv ms dp structure 11kv 200a 3 ph supply as specified , sf 11 kv 200 amp gaob switch as specified , sf 11 kv 200 amp heavy duty dropout fuse set as specified , replacment of ligting arrestor 9 kv, 5 ka as specified , replacement of polymer disc insulator 11 kv as specified , replacement of polymer pin insulator 11 kv as specified , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick as specified , pvd fixing 25mm x 25mm gi strip in 40 mm dia gi pipe , pvd fixing 25mm x 25mm gi strip on surface or recess , supply laying 3 core 95 sq mm xlpe ht power cable 11kv in rcc hume pipe as specified , supply making indoor cable end termination with heat shrinkable jointing kit for 95 sq mm cable , supply making straight through cable jointing with heat shrinkable jointing kit for 95 sq mm cable , re fixing of existing protection cover arrangeement with wire mesh ms angle structure etc , providing gi or ms wire mesh i.e. netting of weleded or woven gi or ms wires , supply fixing ms structure of suitable size
Tender For bifurcation of 11 kv sanjeevpuram feeder emanating from 33/11 kv zamisthanpur ss and srinivasa nagar feeder emanating from 33/11kv seethaphalmandi ss by erection of new 11kv feeder from 33/11kv seethaphalmandi ss which involves laying of 1.46km 11kv 3x300sqmm xlpe ug cable (double run) up to the existing pole of the autorecloser point and line ab switch near vinayaka gods power gym along with erection of 1no. 11 kv feeder vcb at 33/11kv seethaphalmandi ss in seethaphalmandi section of padmarao nagar sub-division in paradise division of secunderabad circle under t and d improvements to original works under general category.
Tender For supply, installation, testing and commissioning of electrical panels and supply & laying of cable for augmentation of power supply to provide ac load for biochemical engineering, pharmaceutical engineering, chemical engineering,.................................... and supply, installation, testing and commissioning of passenger lift with rcc lift pit etc. at iit (bhu), varanasi. (sh supply, installation, testing and commissioning of electrical panel and supplying and laying of cable) (sh indoor plantation work at cpwd electrical office)
Tender For tender for supply, installation testing and commissioning of it & electrical components for vams - supply and installation of 12u rack, supply and installation of 12 port managed n/w switch, supply and installation of 8 port managed n/w switch, 4+2 poe switch for power up the ip camera, supply and installation of gigabyte media convertor, supply and installation of patch cards, supply and installation of power jb, supply and installation of control jb, supply and installation of long-range wifi router, supply and installation of 6c sc ofc cable, supply and laying of 3c*2.5 sqmm armoured cable, supply and laying of cat-6 cable, supply and installation of 42 u rack, supply and installation of 24 port managed switch, supply and installation of pdp pannel, supply and installation of p10 display unit with 2 feet, * 6inch for driver information purpose, supply and installation of 10kva ups 3phase in, 1phase out with redundant setup, supply and installation of smf battery 42ah, supply and installation of battery stand and interlinks, flp gland, non flp gland
Tender For corrigendum : additional cable laying work for new upgraded lt panel at main building honble supreme court of indiasubwork/packages:provision of vc panel for restoration of power supply in transformer no. 4
Tender For bid to ras supply of diesel power generator (up to 900 kva) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) , s & f earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick , supply & fixing or laying hdpe dwc pipe of 120 mm dia (outer dia-120 mm & inner dia-103 mm nominal)
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia
Tender For supply of supplying of inverter type split ac , itc of inverter type split ac unit , supplying and fixing extra copper pipe line , providing and fixing pvc pipe , supplying and fixing heavy duty iron stand , supplying and laying 3 core 2 point 5 sqmm copper cable , supplying and fixing programmable timmer , removing of all window split ac , closing the opening of window ac , supplying and fixing spn 4 way single door mcb db , wiring for light power plug with 2 into 4 sqmm copper cable , supplying and fixing 20 a sp mcb , supplying and fixing 40 a dp isolator