Web Analytics Made Easy - StatCounter

Wire Scrap Tenders

Get complete information related to latest Wire Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wire Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wire Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45744879 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For purchasing the 1)cable scrap -xlpe aluminum single core cable 1500 kg ,wp pvc wire scrap (aluminum)- 500 kg , ct/pt unit (pgr power tech model)- 1 unit ,ct/pt unit (suman controls type 1 model)- 4 pieces ,ct/pt unit (suman controls type 2 model)- 1 piece ,ct/pt g (indian transformers)-3

corporations/Associations/Others

CTN :45723624 Due date: 02 Jul, 202602 Jul, 2026 6.00 Lacs
Tender For supply delivery and fixing of motor and accessories at ward-1 selliyampalayam oht in narasingapuram municipality - supply and delivery of kirloskar make 15hp/11kw/2900rpm three phase/415v/50hz/ac/tefc horizontal centrifugal monoblock pump impeller-mechanical seal (head-20mtr,flow rate-2154lpm) size:100x100mm (local quotation) 15hp horizontal centrifugal monoblock pump, labour charges for erection of horizontal shaft, centrifugal pumpset (coupled/monoblock) in bore well/open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of tpic switches starter, voltmeter, ammeter, capacitor single phasing preventor and laying and jointing the cables and twinearthing as per ie rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by eb authorities., three phase panel board star- delta with two level guard and auto start supply and delivery of star-delta starter confirming to is 13947, iec60947-1 and as amended thereafter with suitable kw rating for operation in ac/ three phase/50hz (+/- 5%) and 415v (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., ct operated ammeter (65 mm dia) with suppressed scale,voltmeter (65mm dia),voltmeter selector switch,miniature circuit breaker, thermal overload relay, air break contactors suitable for next standard higher kw rating, single phasing preventor, dry running preventor and on/off push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capa citor is to be taken separately). three phase panel board for 15hp, supply,delivery and fixing of the following materials are listed below etc..,as directed by the departmental ofiicers.for service4 core 16sq.mm pvc copper ug cable, for motor3 core 6sq.mm pvc insulated and sheathed flat type copper cable, 150mm di pipe, 100mm gi pipe , 100mm gi flange set, rubber sheet for flange set, ms bolt and nut20mm dia and above x 90mm to120mm length fully threaded bolts andwith nuts 2 nos. , manhole cover 60 x 60cm (heavy duty) with frame, supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary ms flange of table e , gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the departmental officers. 150mm sluice valve, 100amps 4pole mcb, 100amps porcelain fuse unit (500v), 32mm pipe

Central Government/Public Sector

CTN :45707591 Due date: 15 Jul, 202615 Jul, 2026 30.00 Lacs
Tender For repairing replacement of internal wiring fitting and fixture and various type of led fitting and connected earthing items at domestic area at af stn naliya - materila and labour for point wiring with 1.5 sq mm frlsh single core pvc insulated unsheathed 1100 v grade with multistranded copper conductor drawn through pvc casing and capping with all accessories fixed to wall froofs ceiling etc and incl provision of 1.5 sq mm pvc insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including pvc box isi marked of suitable size for mounting the switches, socket outlets, fan regulators etc., complete all as specified and directed for following:- one light/fan point controlled by one switch. one socket 3 pin outlet 5 amp on independent board. one light point controlled by two 2-way switches. one 3 pin socket outlet 5 amp on the same board with other switches. one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. all as per serial item number 2.00 here-in-before but with copper conductor cable of 2.5 sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor. supply and fix in replacment of switch piano flush type single pole one way 5 amp, complete all as specified and directed. supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. supply only socket outlet multipurpose 213 pin 5 amps flush button type with universal box in polycarbonate complete all as specified and directed. supply only switch socket multipurpose 2 in 1,5 and 15 amps complete all as specified and directed. supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed. supply only switch bell push, flush type 5 amp. supply only electric bell ding-dong ac 230 volt sp with brass screws and cup washers all as specified and directed. pa supply only hylem sheet 3 mm thick size 9" x 11" including cutting of switch,socket complete all as specified supply only hylem sheet 3 mm thick size 8" x 5" including cutting of switch,socket complete all as specified supply only mcb single pole and neutral 32-63 amps, 240 volts, complete all as specified and directed. all as per item ser no 60 above but with two run of single core 6 sq mm and one run of 6 sq mm frlsh as earth wire s&f in replacement of 9 watt led bolard lights 4300/6500 k in rectangular shaped victorian design with opal acrylic diffuser and ip 65 protection,including pcc work for mounting the fittings with suitable size of nut, bolts and connection with two core copper cable all as specified and as directed. make bajaj, havells, crompton. m&l for repair / maint of wooden/steel boards for electrical db of any type and size including replacement of doors as per site requirement, hinges, handle and locking arrangement with necessary welding works, wooden works to make good the wooden / steel boards including painting with synthetic enamel paint of one coat all etc complete. the quoted shall be inclusive of replacement of wooden doors! steel doors/hinges! locking system/welding work required for repair/fixing of new doors etc complete pac s&f in replacement of 36w led recessed 2x2 luminaire 6500k fixed in the existing ceiling/roofs white powder coated crca housing with led seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size in kutch auditorium with ceiling height of more than 20 feet including necessary arrangement for scaffolding ladder for replacement of ceiling lights all as specified and as directed. note: the quoted rates are inclusive of necessary safety arrangements iscaffolding/ladder etc complete all as specified and directed

Central Government/Public Sector

CTN :45709067 Due date: 18 Jul, 202618 Jul, 2026 45.00 Lacs
Tender For repair replacement of internal wiring incl sub main wiring, mcb dbs, bldgs security lights and connected items in pocket 1 to 8 under ge roorkee - taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed., m&l for point wiring with 1.5 sqmm frls-h insulated, unsheathed, multistranded, 1100 volts grade copper conductor cable single core conforming to is:694 along with one run of 1.5 sqmm frls-h insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(od), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass gi screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., all as per item no 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch., all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on independent board, all as per item no 2 here-in-before but one one 6a socket point controlled by one switch on same board, all as per item no 2 here-in-before but one one light point controlled by two no. two way switch complete all as specified and directed, all as per item no. 2 here-in-before but one 16a socket point controlled by one 16a switch on independent board with 2.5 sqmm wires., m&l for sub main wiring along with earth wire with frls-h insulated copper conductor, single core cable drawn through and including medium grade rigid pvc conduit conforming to is:9537 (pt-iii) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(ph & n) + 1run x 4 sqmm(earth wire):- (note: three runs of copper cable and one run of pvc conduit shall be measured as one unit length), all as per item no 11 here-in-before but 2runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), all as per item no 11 here-in-before but 2runs x 10 sqmm(ph & n) + 1run x 10 sqmm(earth wire), all as per item no 11 here-in-before but 4runs x 6 sqmm(ph & n) + 1run x 6 sqmm(earth wire), notes for item no. 2.00 to 14.00(i) quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) if any beam / column / rock wall is encountered while cutting chases, that particular portion may be provided with pvc casing & capping or surface conduit for drawing cables and surface pvc gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) no cutting shall be done on ceiling for laying pvc conduit for ceiling fan point wiring. surface conduit or pvc casing capping may be

Central Government/Public Sector

CTN :45711072 Due date: 20 Jul, 202620 Jul, 2026 36.87 Lacs
Tender For special repair to dbs sub main wiring and miscellaneous items at mh and central institute at old amritsar cantt - taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed., material and labour for point wiring in existing conduit for following point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn through and existing pvc concealed/conduit with all fittings and accessories including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floorsetc by using cement mortar (1:3) complete all as specified and as directed. note : 1 switch, socket, regulator, bell, ceiling rose, regulator, lamp holder will be measured and paid separately.a) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board., c) for one three pin 5 amps socket outlet on the same board with other switch, d) for one light point controlled by two way switch, all a per item no 2 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper multi stranded conductor connecting to common earth dolly complete all as specified and directed., material and labour for surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core frls pvc insulated unsheathed and multi stranded copper conductor cable 1100 volt ( isi marked ) drawn and including surface pvc conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken terminal box suitable for modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core frls pvc insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc including necessary cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using cement mortar (1:3) complete all as specified and as directed. note : 1. switche, socket, regulator, ceiling rose, bell, lamp holder will be measured and paid separatelya) for one light /fan/ buzzer point controlled by one 5 amp switch one way, b). for one three pin socket outlet 5 amps independent board, c) for one three pin 5 amps socket outlet on the same board with other switches, d) for one light point controlled by two way switch, all a per item no 7 here-in-above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 2.5 sq mm copper solid conductor connecting to common earth dolly complete all as sp

Central Government/Public Sector

CTN :45713842 Due date: 18 Jul, 202618 Jul, 2026 36.00 Lacs
Tender For maintenance of point wiring, old unsv fan and geysers, db and light fittings with other connected items in otm and md accn at ghatkopar and vikhroli area under ge (n) santacruz mumbai - supply & fix including taking down sub main wiring with two run of 06 sqmm stranded copper conductor frls wire with one run of 06 sqmm stranded copper conductor as earth continuity conductor connected to common earth dolly including pvc fr heavy duty conduit of adequate size for housing the wires from main db to spn db complete all as specified directed by engr in charge. note: two runs of 06 sqmm cable and one run of 06 sqmm cable with pvc conduit shall be measured as one length. make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for sub main wiring with two single core 04 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty, isi marked of suitable size for sub main wiring including 04 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- two runs of 04 sqmm copper conductor cable, one run of 04 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for three phase sub main wiring with 4 single core 10 sqmm multi stranded copper conductor, frlsh pvc insulated, unsheathed cable including rigid non metallic pvc fr conduit heavy duty of adequate size, isi marked, not less than 25 mm dia for sub main wiring including 10 sqmm frlsh pvc insulated and unsheathed stranded copper conductor as earth wire in surface/recess complete all as specified and directed. note:- four runs of 10 sqmm copper conductor cable, one run of 10 sqmm copper conductor and one run of pvc conduit will be measured as one unit.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, material and labour including taking down for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, frlsh, passing through pvc casing capping/pvc conduit including all fittings and accessories for mounting of switches & sockets as required at site along with one run of pvc insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) frlsh as earth wire connected to earth dolly complete all as specified & as directed by engr-in-charge for one light point/ exhaust/wall/ceiling fan controlled by one switch.make of cable- anchor/ havells/finolex /polycab/plaza of isi mark as approved by gemake of pvc conduit/ pvc capping-anchor, modi, pressfit, precision, astral, panasonic anchor, polycab, presto plast, supreme, all as per item no.4 above but one bell point controlled by one bell push., all as per serial no.4 here-in but for one light point controlled by two way switches (two way switch point wiring), all as per item no.4 but one 3 pin socket point 5 amps on independent board, all as per item no.4 but one 3 pin socket point 5 amps on same board, all as per item no 4 here-in-before but for one socket point 15 amp with 2.5 sq mm pvc unsheathed frlsh wire along with 2.5 sq mm green colour wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed., all as per item no 4 here-in-before but for point wiring on independent board with 4sqmm copper cable and provision of 4sqmm pvc insulated frls cable 1100 volts grade with

Central Government/Public Sector

CTN :45713891 Due date: 20 Jul, 202620 Jul, 2026 20.00 Lacs
Tender For repair / maint of split acs 2/1.5 ton , windows acs 2 / 1.5 ton , voltage stablizers and connected items installed at command hospital (wc) and other various location in aor of age e/m ch - servicing of split type ac of capacity 2/ 1.5 tr after disconnecting all incoming and outgoing electric connection, water drain pipe line connection etc. and wash with approved chemical mixed water with the pressure pump, after servicing cleaned all the disturbed area and reassembling the water/electric connection and testing for entire satisfaction of engr-in-charge., all as per item no. 1 here-in-above but window type ac 2/1.5 tr capacity., supplying and charging of refrigerant gas r-22 only after vacuuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and as directed by engr-in-charge for room split/window type ac of capacity 2/1.5 tr., all as per item no: 3 above but gas r-32, all as per item no: 3 above but gas r-410a., all as per item no: 3 above but gas r-134a., taking out defective capacitor of capacity 50+6 mfd after disconnecting all incoming and outgoing electric connection including supply & fix new capacitor on same place and testing complete all as specified and as directed by engr-in-charge, all as per item no:7 here in above but of capacity 45+4 mfd ., all as per item no:7 here in above but of capacity 45 mfd ., all as per item no: 7 here in above but of capacity 6 mfd ., all as per item no: 7 here in above but of capacity 4 mfd ., supply & fixing as in replacement copper pipe 1/2" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 1/4" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 5/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply & fixing as in replacement copper pipe 3/8" for liquid line including fittings and testing complete all as specified and as directed by engr-in-charge., supply and fixing of insulation foam for copper pipe of size 1/2" after removing old one., supply and fixing of insulation foam for copper pipe of size 1/4" after removing old one., supply and fixing of insulation foam for copper pipe of size 5/8" after removing old one., supply and fixing of insulation foam for copper pipe of size 3/8" after removing old one., supply and fixing as in replacement of pvc flexible pipe 15 mm dia including any fittings as required complete inclusive of any type of leakage testing., all as per item no: 20 above but pipe of 20 mm dia., supply and fixing as in replacement of pvc water drain pipe 25 mm dia complete inclusive all fittings and any type of leakage testing., material and labour for sub main wiring with 2 x 2.5 sqmm +1 x 2.5 sqmm single core flame retardant pvc insulated unsheathed cable with stranded copper conductor drawn in and including heavy grade frlsh pvc concealed conduit isi marked with all accessories on walls and making good the disturbed surfaces including all conduits fittings, clamps guittes etc for earth dbs and boxes with proper thimbles all as directed by engr-in-charge. note :02 run of 2.5 sqmm , 01 run of 2.5 sqmm cable and 01 run of conduit shall be measured as one unit and paid accordingly., all as per item no: 23 here in above but of size 2x 4 sqmm +1x 4 sqmm., m&l cutting chases, pinning in stone concrete block or slab walls & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring ,etc., and making good, cutting exc. 10 cm girth., supply and fix as in replacement of rigid non-metallic pvc conduit of size 20

Central Government/Public Sector

CTN :45492541 Due date: 10 Jul, 202610 Jul, 2026 3.16 Crore
Tender For corrigendum : tender for supply of fids and 05 years camc at srinagar airport : - supply of 3 x 2 mtrs. or higher true colour led display board with stainless steel floor ceiling wall mounting arrangement. , supply of 65 inch led display with floorceiling wall mounts as per the specifications , supply of 55 inch led display with floor ceiling wall mounts as per the specifications , supply of 43 inch led display with floor ceiling wall mounts as per the specifications , supply of fids servers to work as main and standby set of two servers with accessories as per the tender specifications. , supply of data entry terminal client desktop pc with all accessories as per the tender specifications. , supply of ntp server with accessories as per tender specifications. , supply of licensed operating system server level with support for all servers , supply of operating system at client level pc work station etc. with support for all clients , supply of licensed antivirus server level with support for all servers , supply of licensed antivirus client level with support for all servers , supply of layer 3 network switch as per technical specifications and accessories with rack , patch panel , liu and other accessories , supply of layer 2 network switch as per technical specifications and accessories with rack , patch panel , liu and other accessories , supply of 12v 84ah battery for the 2x 20kva ups of make numeric hp max. the cost of old batteries connected to ups shall be considerd while qouting and shall be handed over to contractor as buy back. , supply of fids package software as per requirement of the tender , supply of 8 port kvm switch. , supply and laying of 25 mm dia , 16 swg isi marked pvc conduit with accessories as required , supply and laying of 3 core 6 sq mm multi strand copper conductor pvc insulated pvc sheathed armoured power cable on wall surface tray with accessories as required , supply and laying of 3 core 1.5 sq mm multistrand copper conductor pvc insulated pvc sheathed unarmoured power cable in existing conduit tray with accessories as required , supply and laying of 6 core smf ofc unarmoured cable on wall surface tray with accessories as required , supply and laying of utp cat 6 cable in existing conduit tray with accessories including termination with wall surface mount box as required , supply of power distribution panel complete as per specifications for flds system. , excavation soft digging back filling as per site requirement , supply of rj45 io face plate gang boxback box with standard length of patch cable for fid system as per site requirement and specifications , training and documentation as per tender , charges for installation testing and commissioning of the complete system including integration of existing 24 nos , cids with new fids system.

Central Government/Public Sector

CTN :45725095 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For supply of insulated electrical tools customised set - combination pliers, long nose pliers, diagonal cutter, stripping pliers, water pump pliers, cable cutter, 4 pcs philips screw drivers of following sizes, 5 pcs slotted (flathead) screw drivers of following sizes, straight knife, voltage tester, 17 pcs 1/2" sockets of following sizes (in mm), 1/2" sockets set accessories, 13 pcs open wrenches of following sizes (in mm), adjustable wrench

CTN :45559938 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For bid to ras supply of heavy duty 1300 watt preferably 12 inch portable pa speaker , active self powered preferably 12 inch two way portable pa loudspeaker , mt series audio mixer usb or bt , digital crossover , xlr connectors for wires , 2 core fibre cable copper conductor pvc insulated 24 awg , wall mount pole stand , heavy duty wall clamps for supporting mount stands , installation and commissioning of fitment accessories
 Loading, Please wait...

Connect us via What's Up