Get complete information related to latest Wooden Pole Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wooden Pole Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wooden Pole Repair Tenders.
Tender For supply of stationary storage type electric water heaters (geyser) (v3) isi marked to is 2082 (q2) , propeller type ac ventilating fans (exhaust fan) (v3) conforming to is 2312 (q2) , m and l for point wiring with in repair pvc insulated pvc unsheathed electric frlsh cable 1100v grade 2 core copper conductor of size 2.5 sqmm mounting switches sockets of 15 amps , supply and fix switch piano flush button single pole one way 15 amps 230 volts complete all as specified and as directed , supply and fix socket outlet flush type multipurpose 2 in 1 comma 3 pin 5 and 15 amp comma 230 volts complete all as specified and as directed , cutting existing steel tubing for alternation or addition and screwing existing steel tubing for alteration or addition lengthening screw on pipe to form connector of size 15 mm dia , supply and fix gi pipe medium grade with all fittings 15mm bore and fixed to wall or laid in flooor complete all as specified and directed , supply and fix pvc connection pipe hot and cold type comma 15 mm dia comma 450 mm long with brass adopter and washer on both sides complete all as specified and directed , supply and fix 15 mm bore bib tap cast copper alloy with crutch or butterfly handle screwed down for iron pipe or brass ferrule and fixed complete all as specified and directed , supply and fix 15 mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as directed , supply and fix for ceiling rose surface bakelite with 3 terminals isi marked for batten fitting complete all as specified
Tender For repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in an
Tender For supply of electrical items -good to match with existing surface complete all as specified and directed by eic , supply and fixing in repair modular metal flush box of 4 module with white cover plate including , supply and fixing in repair modular metal flush box of 6 module with white cover plate , material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick , supply and fixing of led wall light bed side light fitting for study table including 3 watt led, aluminium body, , supply only inner container ss or as per sample suitable for vertical type geyser 50 itrs storage capacity , supply only inner container ss or as per sample suitable for vertical type geyser 25 itrs storage capacity , supply only in repair thermostat 0-75 degree as per exiting size as per oems specifications complete all as specified and directed , supply only in repair heating clement 1.5 kw, as per oems specifications all as specified and directed , supply only in repair heating element 2 kw, as per oems specifications all as specified and directed , supply only indicator lamp with flexibe copper wire of suitable size red by green , supply and fixing pvc connection with steel reinforced pipe for hot water connection of size 18 inches x 1 by 2 inches , supply only apperture plate ss suitable for 25 by 50 itrs geyser along with rubber gasket, nuts, bolts, etc , supply and fixing in repairs plug top 15 by 16 amps suitable for geyser socket outlet complete all as specified and as directed , supply and fixing in repair stop valve but fancy type, chromium plated, screwed down cp of size 15 mm fancy type complete all as specified and directed. , supply and fixing in repair bib taps, cast copper alloy with butterfly handle, screwed down, screwed for iron pipe , supply and fixing of solar collector plate panel as per existing size, specification and make of capacity upto 200 lpd , supply and fixing of solar water heater tank as per existing size, specification and make of capacity upto 300 lpd , supply and fixing of cimfr certified led fiame proof batten suitable for single t8 tube of 20 watt, ip 65 protected , supply and fixing cimfr certified led flame proof bay light, 60 watt, well glass in die cast al housing with heat resistant toughened glass, ip 65 protected. 240 volt, , supply and fixing of flame proof weather proof rotary switch with cable termination box in lm 6 aluminium allcy housing single pole 16 amp, 250 volts , supply and fixing of flame proof-weather proof switch socket and plug combined 16 a, 250 v 2p plus earth , supply and fixing of flame proof weather proof switch socket and plug combined 32 a, 500 v 4p plus earth , supply and fixing of flame proof weather proof metallic hose conduit 3 by 4 inches dia, m20 by 3 by 4 inches conduit mxm by fm x m by fx f 3 by 4 inches dia 300 mm long , supply and fixing of flame proof weather proof metallic hose conduit 3 by 4 inches dia, m20 by 3 by 4 inches conduit mxm by fmxmfxf 3 by 4 inches dia 500 mm long , taking down copper by aluminium point wiring light, fan, socket or power complete, including fixture and fittings , supply and fixing for concealed conduit for one light point wiring with 1.5 sqmm nominal cross-sectional area pvc insulated unsheathed single core copper cable working voltage 1100 volts grade , supply and fixing for concealed conduit for one light point wiring with 1.5 sqmm pvc single core cable for one ceiling fan by exhaust fan point controlled by one, one way switch and regulator , supply and fixing for concealed conduit for one light point wiring 1.5 sqmm pvc single core cable for one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. , supply and fixing for concealed conduit for //bid details 3 / 81 one light point wiring with 1.5 sqmm pvc single core cable for one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. , supply and fixing for concealed conduit for one light
Tender For supply of excavation in trenches not exc 1 point 5 mtr wide and 1 point 5 mtr deep , excavation in trenches not exc 1 point 5 mtr wide and 2 mtr deep , returning filling spreading lavelling watering and well ramming , removing excavated material not exc 50 mtr , s and l 50mm outside dia double corrugated pipe , stret light bracket welded and fixing in position complete , supply and fix steel tubular pole 410 sp 22 , 20 mm stone aggregates , 40 mm stone aggregates , pvc insulated water proof 1point 5 sqmm 3 core copper cable , s and f repair of 5kw 3 phase authomatic street light timer switch , supply and fixing street light junction box size 260mm by 210mm by 116mm , wall mounted fan 400mm with all complete accessories , supply and fix water cooler capacity 80 litre , supply and fix deep freezer glass top 320 litres and having double door , supply and fix refrigerator capacity 310 litres bee 5 star , copper wire 1 point 5 sqmm 2c with all accessories , switch socket combination 3 pin 5 or 6a , supply and fix switch socket combination 5 in 1 and 5 or 16 amps , m and l for sub main wiring with 3 run of single core 2 point 5 sqmm , supply install testing and commissioning of 50 kva voltage stabilizer , m and l for pipe earthing galvanised steel 40mm bore , supply and fix on load change over switch 4 pole 100a 415 volt , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) * /bid number : gem/2026/b/7549042 + /dated: 01-06-2026 ' ' / bid document 1 / 25
Tender For corrigendum : supply of excavation soft and loose soil not exceeding 1 point 5 metre deep and wide , returning filling in soilsspreading leveling watering and well ramming , removal of surplus soils not exceeding 50 mtr distance , m and l for sand filling with clean dry fine sand unwashed , s and l un reinforced pre cast with peak concrete cable protection , sitc cable heat shrink jointing kit of 11 kv grade 95 sq mm , sitc cable jointing kit of 11 kv heat shrink type 95 sq mm , s and fixing on ht pole danger notice plate for ht 11kv , sitc end joint for 1100 volt xlpe cable of size 95 to 120 sqmm , sitc heat shrinkable end joint for 1100 volt size150 to 240 sqmm , sitc heat shrinkable end joint for 1100 volt xlpe cable of size 300 to 400 sqmm , tubes light grade galvanised of size 80 mm , m and l for earthing complete with gi steel earth plate 600mm x 600mm x 6mm , m and l earthing complete with copper earth plate of size 600x600x3 point 15 mm , supply and fixing in repair lightning arrester single pole 11 kv 65 kilo amp , sitc of 11kv sf6 gas 4way rmu 630 amps , sitc of 11kv 630a switch sf6 disconnector outdoor panel , supply and installation and testing 11 kv outdoor type god , sitc of 200 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 160 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 100 kva level 03 transformer 11kv on ht and 433 volts on lt side , taking out of transformers 50 kva to 200 kva depositin in mes yeard , taking out old unsv ht ug cable of any size , dismantling air break gang operated switches , xlpe cable, working voltage from 3.3 kv up to and including 33 kv (v2) isi marked to is 7098 (part 2) (q2)
Tender For corrigendum : supply of excavation soft and loose soil not exceeding 1 point 5 metre deep and wide , returning filling in soilsspreading leveling watering and well ramming , removal of surplus soils not exceeding 50 mtr distance , m and l for sand filling with clean dry fine sand unwashed , s and l un reinforced pre cast with peak concrete cable protection , sitc cable heat shrink jointing kit of 11 kv grade 95 sq mm , sitc cable jointing kit of 11 kv heat shrink type 95 sq mm , s and fixing on ht pole danger notice plate for ht 11kv , sitc end joint for 1100 volt xlpe cable of size 95 to 120 sqmm , sitc heat shrinkable end joint for 1100 volt size150 to 240 sqmm , sitc heat shrinkable end joint for 1100 volt xlpe cable of size 300 to 400 sqmm , tubes light grade galvanised of size 80 mm , m and l for earthing complete with gi steel earth plate 600mm x 600mm x 6mm , m and l earthing complete with copper earth plate of size 600x600x3 point 15 mm , m and l for ht heat shrinkable straight through jointing kit size 95 sqmm , supply and fixing in repair lightning arrester single pole 11 kv 65 kilo amp , sitc of 11kv sf6 gas 4way rmu 630 amps , sitc of 11kv 630a switch sf6 disconnector outdoor panel , supply erecting and fixing steel tubular swaged pole 410 sp55 11 mtr long , supply and installation and testing 11 kv outdoor type god , sitc of 100 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 125 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 160 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 250 kva level 03 transformer 11kv on ht and 433 volts on lt side , sitc of 500 kva level 03 transformer 11kv on ht and 433 volts on lt side , taking out of transformers 100 kva to 500 kva depositin in mes yeard , taking out old unsv ht ug cable of any size , dismantling air break gang operated switches , xlpe cable, working voltage from 3.3 kv up to and including 33 kv (v2) isi marked to is 7098 (part 2) (q2)
Tender For repair/ maint of lt over head line, lt pole and busbar with connected accessories at hq igar (e) srikona. - schedule a part - i, supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 25 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 35 sqmm 3.5 core, complete including execavation, sand cushioning , protecting covering and retuning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 50 sqmm 3.5 core, complete including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., supply test & commissioning lt ug cable xlpe insulated sheathed and armoured, with aluminium stranded conductor, lt 1100 volts grade of size 70 sqmm 3.5 core including execavation, sand, sushioning, protecting covering and returning filling all as specified and as directed., m&l for preparation of surfaces of pole for painting of steel tubular pole,vertical with one coat of aluminium paint incluing painting black and white strip or as ordered by engineer-in-charge on poles and numbering with writing letters or figures(block) complete all as directed., s&f street light control panel confirming to ip 66 protection mounted on wall/pole/pcc foundation with suitable ms clamps & nut bolts etc installation and testing including 01 no mcb tpn 63 amp (incomer),01 no contactor 63 amp 3 pole , 230v 3p module astronomical time switch , bakelite fuse fitting with 2 a hrc fuse,indicaion lamp,mounting lugs,panel lock,hinged door,auto manual selector switch 6 amp, detachable mounting din channel,supply monitoring device complete all as specified and directed, supply and fix high efficient ip-66 led street light 70 watt with high power leds, having aluminium pressure die cost housing and pc cover in the front and lens for light distribitioon and saving of energy efficient including service bracket and making of fixing arrengement all as direct by engr -in-charge., labour only for stringing loose lt line alumunium conductors as per direction of engr- in -charge, supply and fixing lt line separator 1100 volts of approved brand and quality, supplying and erection of 100 mm x 65 mm pin insulator complete with g. i. spindle and nuts etc as required .
Tender For repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking capacity with
Tender For maint and repair of street lights security lights and solar lights and its connected items including repair to lt distribution network at mh and 41 arty div under ge mh and rh khadki - taking down old unserviceable lt ug cables of size upto 50 sq mm from trenches / poles / ducts etc complete all as specified and directed., supplying, laying, jointing, commissioning and testing xlpe insulated screened pvc bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to is-7098 (part-i-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by engr in -charge for following sizes . make :- polycab/havells / gloster / finolex note :- earth work , bricks , riddled earth , gi pipe for protection of cable will be measured & paid under relevant items of schdule . , 50 sq mm 3.5 core ., 35 sq mm 3.5 core, 25 sq mm 3.5 core, 16 sq mm 4 core., 10 sq mm 2 core, 6 sq mm 2 core, excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed., ditto item no 3 but in hard/dense soil., removing excavated material soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed, returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed., material and labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as directed. note - punned thickness shall only be measured & paid ., material and labour for road cutting/foot path and making good with pcc 1:3:6 type c-2 ( using 40 mm graded stone aggregate ) of 150 mm depth complete all as specified and directed., supply and laying un-reinforced precast concrete cable cover lv, type i, flat, size 250mm x 150mm x 40mm for under ground cable all as specified and directed., supply and laying gi tubes light grade, galvanized, 40 mm bore in repair ,laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed, ditto item no -10 but 80 mm bore., material and labour for plain cement concrete (pcc) 1:3:6 type c2 using 40mm graded stone aggregate for making foundation of pole/stay assembly complete all as specified and directed., material and labour for plain cement concrete (pcc) 1:3:6 type c1 using 20mm graded stone aggregate for making copings of poles etc complete all as specified and directed. ., material and labour for earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5mtr below normal ground level, connected to the earth lead wire 4.0 mm dia (gi wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of gi medium grade pipe 15 mm bore including provision of 40 mm thick cover of rcc (1:2:4) 20mm graded stone aggregate re-inforced with xpm (weight not less than 4 kg per sqm) and frame of angle iron 40x40x3 mm with lugs 02 nos and with 6 mm dia ms bar handle made to shape, gi light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate no 3 of ssr 2009 part-i and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. , material and labour fo
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins