Get complete information related to latest Wooden Pulley Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wooden Pulley Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wooden Pulley Scrap Tenders.
Tender For manual operated chain pulley block 3t capacity, working height: 20 meters, class-2 for indoor use in industrial area with standard code as per is:3832/2005 along with all accessories having isi mark on chain pulley block as per technical specification enclosed at annexure-b. note:- is certification to be provided for chain pulley block at the time of supply. make: bemco or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For bid to ras bid to ras supply of 1000072404_1_67402000290_1 ton cap chain pulley block , 1000072404_2_67402083590_2 ton cap chain pulley block , 1000072404_3_13310040790_lock spring for gf- 4 seed filter , 1000072404_4_13310012070_spray nozzle for disc filter cloth washing , 1000072404_5_13108006300_m12 stud with nut for bokela filter. , 1000072404_6_13200001120_sector spring for gf-4 disc filter
Tender For corrigendum : supply, installation, testing and commissioning of 40 hp, 980 rpm vt motor and supply, installation, testing and commissioning of 01 tone chain pulley block at ls zazna-a.
Tender For tender for supply of repair maintenance and servicing of eot crane 2 ton - servicing and maintenance of cranes 02 ton an all allied works with load test. , bridge & cross traverse rail alignment by clamps fitting/ adjustment , replace repaire dsl or ip supply cable on long travel , replace current collector for smooth operation , hoisting motor 5.2kw , 3ph , sc servecing only , cross traverse motor 0.55kw , 3ph , sc servecing only , long travel motor 2.2kw , 3ph , sc servecing only , bridge wheel assembly maintenance and replacement of defective part any of wheel , bearing , spacer , shaft , coupling , brake , gearbox , trolley crab wheel assembly maintenance and replacement of defective part any of wheel , bearing , spacer , shaft , coupling , brake , gearbox , hoock block maintainance and replacement of defective part any of pullies , rope lock , pulley bearing , thurster bearing , cover fastners , replacement of hoist wire rope dia 12 6 nos 36 fibre core , hoist assembly maintenance and replacement of defective part any of coupling , brake shoes , bearing , spacer , shaft , gear. , equiliser pulley maintenance and replacement of defective part any of pulley , shaft , bearing , maintainance for span of the crane within limit , it must not wear wheels on either sides of flanges , maintainance for diagonals of crane within the limit , it must not wear flanges of lt wheels or must not get jam of lt motion , rubber buffers replacement , limit switch for any of motion long travel cross traverse hoisting ) , relay maintenance or replacement with accessories , cross traverse cable replacement , cross traverse cable trollies maintenance or replacement
Tender For repairing and overhauling of one no twin lobe air blower assembly and renovation of 2 nos outgoing motor (blower ) feeder of lt pdb with supply, fitting and fixing spares at sludge pump house under swtp, kmda. - supply,installation,testing and commisioning of following items for hoisting system/ blower and gear box as mentioned below as per direction including cost of materials, machinaries , manpower, cutting,machining,aligning,anchoring,welding,finishing,consumables, carriage and all overheads with all leads and lifts complete as per specification (without painting), i) base frame (ms), ii) shaft/pin with key ways made of ss-304, iii) gear& pinion (forged steel), supply and fixing the 3way c.i v grooved pulley with complete mechanism key way suitable to en-24, 60 mm dia/ as per sample of shaft end., a) motor driving, b) blower driving, supply of gear oil as per direction of engineer in charge., supply of grease, supply and delivery of the following bearing (make: skf):, i) 22312e/c3/ as per sample. (for blower), supply and fixing of tough v belts (make: fenner/power boom / v guard/benq/ecodrive) of the following size c 98/ as per sample., supply fitting fixing of ss (aisi304) bolts,nut & washer i) dia 10 mm to 20 mm a) length upto 75 mm, refixing of impeller of blower after dynamic balancing in workshop as per is rule after dismantling the same., dismantling the 25/30 h.p (18.5 kw)//30 h.p squirrel cage motor from its foundation by opening mounting bolts and disconnection of cables from terminal box and open the v belts for repairing purpose (in condition), preliminary checking of the whole motor (lt sq. cage im) and testing of i.r. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of d.e. & nde shield bearing housing etc. before work to detect fault., complete servicing and heat varnishing of 415volt, 3 phase l.t. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by dr. beck s graded insulating varnish to obtain stable ir value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and ro priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of e.i.c.upto 75kw lt sq. cage im ], re fixing the 25/30h.p star/delta squirrel cage motor over its foundation by mean of mounting bolts & nuts, washer complete connection of existing led of cable at the terminal box and wear the v belts with proper alignment in respect to i.d. fan (12000 cu m/hr capacity)/ blower by adjusting the side rail for smooth running., finishing the end of terminal leads by s & f dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.upto 75kw lt sq. cage im., cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc. upto 75kw lt sq. cage im., inspection checking/testing and servicing of the existing starter panel, all terminal connection, contactors, relays etc as per desired technical specification including man and minor materials for proper functioning as per direction of eic., supply and fixing of 240/230 volt, 50 hz, t.p., power contactor (make: l & /abb/schneider/ simence/ ge) having contact block of the following range.32-55amp, supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) blue/ white color., supply & fixing of 230/240v, led indicating lamp make :ae/kappa/imp) other than blue/ white color., supply and delivery of thermal overload relays (make: l & t/abb/schneider/simence/ ge/minilec) of the following range:a) 0.2-0.33/ 0.3-0,5/ 0.45-0.75, mn2, supply of ammeter selector switch current in each phase with off, 4 pos. 90 angle ofthrow (off-r-y-b) , supply and fixing of analog ammeter ranging