Get complete information related to latest X Ray Films Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic X Ray Films Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding X Ray Films Tenders.
Tender For providing of custom bid for services - lumpsum job scope for cdu - 1.a. blinding and deblinding - rate per , 1.b. blinding and de-blinding with using , 1.c. blinding and de-blinding with using , 1.d. gasket repacement , 1.e. gasket repacement using non sparkin , 1.f. gasket repacement using torque wren , 1.g. bolt servicing upto 12" dia flanges , 1.h. bolt servicing above 12" dia flange , 1.i. bolt servicing from 24" dia flanges , 1.j. bolt servicing upto 12" dia flanges , 1.k. bolt servicing above 12" dia flange , 1.l. bolt servicing from 24" dia flanges , 1.m. bolt servicing upto 12" dia flanges , 1.n. bolt servicing above 12" dia flange , 1.o. bolt servicing from 24" dia flanges , 1.p arresting flange leaks , 1.q. arresting flange leaks using non sp , 1.r. arresting flange leaks using torque , 1.s. opening of flange using flange spre , 1.t blind fabrication , 1.u. plate flange fabrication , 1.v. cold cutting of pipelines , 1.w. providing air / steam hose connecti , 1.x. splitting of nuts using nut splitte , 1.y. bolts cutting with hacksaw/grinding , 2.a. piping - cs fillet joint per inch d , 2.b. piping - cs fillet joint per inch d , 2.c. piping - cs fillet joint per inch d , 2.d. piping - as/ss fillet joint (smaw) , 2.e. piping - as/ss fillet joint (tig) , 2.f. piping - fillet joint monel/inconel , 2.g. piping - fillet joint monel/inconel , 2.h. piping - cs butt joint non xray qu , 2.i. piping - cs butt joint xray qualit , 2.j. piping - cs butt joint xray qualit , 2.k. piping - cs butt joint xray qualit , 2.l. piping - as/ss butt joint (tig root , 2.m. piping - as/ss butt joint (tig) , 2.n. piping - butt joint monel/inconel ( , 2.o. piping - butt joint monel/inconel ( , 2.p. piping - cs corrosion pad per inch , 2.q piping - cs corrosion pad with shoe , 2.r. piping - as/ss corrosion pad per in , 2.s. piping - as/ss corrosion pad with s , 2.t. wrap coating using "pykote" of 4 mm , 2.u. nozzle replacement/provision, rate , 2.v. cs gusset fabrication n welding per , 2.w. as/ss gusset fabrication n welding , 2.x. piping - cs rf pad per inch dia usi , 2.y. piping - as/ss rf pad per inch dia , 2.z. non-pressurized piping welding join , 2.aa. grit blasting , 2.bb. primer painting - inorganic zinc s , 2.cc. painting - for insulated pipe havi , 2.dd. painting - for insulated pipe havi , 2.ee. manual cleaning of pipelines , 2.ff. erection / dismantling of piping / , 2.gg. hot work area preparation in runni , 2.hh. hot work area preparation in runni , 2.ii. hot work area preparation in runni , 2.jj. hot work area preparation in runni , 2.kk. power tool cleaning on surfaces , 3.a. dye penetrant test , rate per inch , 3.b. dye penetrant test , rate per runni , 3.c. dye penetrant test , rate per sq me , 3.d. wfmpt, rate per inch dia of wfmpt d , 4.a. radiography on piping with iridium , 4.b. radiography on piping or any other , 4.d. radiography on piping with selenium , 4.e. radiography on piping or any other , 4.g. mobilization charges for digital ra , 4.h. radiography film devolopment with d , 4.i. profile radiogrpahy of surface - mo , 4.j. profile radiogrpahy of surface - re , 4.k. profile radiogrpahy of surface - ch , 4.l. profile radiogrpahy of surface - re , 4.m. profile radiogrpahy of surface - ch , 5.a. stress relieving done using electri , 5.b. stress relieving done using electri , 5.c. stress relieving done using electri , 6. ultrasonic flaw detection test. rate , 7.a. overlay patch work (rate per sq.foo , 7.b. overlay patch work (rate per sq.foo , 8.a. inlay patch work - cs inlay patch p , 8.b. inlay patch work - ss inlay patch p , 9. replacement of casing plates 8 mm thk , 10.a. weld build up cs – upto 1000 sq in , 10.b. weld build up cs – from 1001 sq in , 10.c. weld build up cs – from 3001 sq in , 10.d. weld build up cs – from 5001 sq in , 10.e. weld build up cs – above 10000 sq , 10.f. weld build up as / ss (all varieti , 10.g. weld build up as / ss (all varieti , 10.h. weld build up as / ss (all varieti ,
Tender For corrigendum : supply of schedule iv (x-rayfilms, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-rayfilms, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-rayfilms (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-rayfilms (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-rayfilms (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-rayfilms intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr