Get complete information related to latest Xlpe Cable Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Xlpe Cable Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Xlpe Cable Laying Tenders.
Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cablexlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cablexlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cablexlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cablexlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cablexlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cablexlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cablexlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cablexlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cablexlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cablexlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cablexlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For supply of safe carriage of 8.5 m long pcc , safe carriage of 11 m long pcc , safe carriage of 9 m long stp , safe carriage of 11 and 13 m long stp , safe carriage of line material , safe carriage of xlpecable , safe carriage of 11 kv ct pt pole mounting , safe carriage of 10 and 16 kva tf , safe carriage of 25 and 63 kva tf , safe carriage of 100 kva tf , etection of 8.5 m long pcc single support , etection of 9 m long stp single support , etection of 11 and 13 m long stp single support , etection of 11 m long pcc single support , etection of 8.5 m long pcc double pole section pole , etection of 11 m long pcc double pole section pole , etection of 11 and 13 m long stp double pole with tpmo etc , laying sagging of dog conductor , laying sagging of acsr weasel conductor , laying sagging of lt xlpecable , laying sagging of 11 kv xlpecable , laying sagging of ab cable , fixing of stay rod , fixing of 3 phase distribution box , erection of 11 kv ct pt pole mounting unit , installation of 11 kv pilfer metering cubical , providing and fixing of suspension clamp , providing and fixing of nut bolts off size , providing and fixing of lt shackle insulator , providing and fixing of dead end clamp , providing and fixing of stone pad , providing and fixing of danger board , providing and fixing of barbed wire , providing and fixing of number plate , fixing of joint kit outdoor , fixing of joint kit indoor , mounting of 10 and 16 kva tf , mounting of 25 and 63 kva tf , mounting of 100 kva tf , earthing of pcc pole stp dt , new guarding of ht lines with gi wire , carriage of acsr dog weseal conductor scrap , carriage of line material scrap , carriage of st pole scrap * /bid number : gem/2026/b/7664537 + /dated: 17-06-2026 ' ' / bid document 1 / 30
Tender For supply of supply of stone pad , supply of ms top channel , supply of ms dropper channel , supply of ms t off channel , supply of lt clamp , supply of danger board , supply of prc connector , supply of i hook , supply of dead and clamp , supply of suspension clamp , supply of ms angle , supply of barbed wire , supply of f clamp , supply of number plate , supply of holding clamp , supply of double pole clamp , supply of e bracket , supply of henley type lailless unit , supply of lt pvc cable , supply of distribution box clamp , supply of clamp with nut and bolts , supply of allunimum lug 25 kva tf , supply of allunimum lug 63 kva tf , supply of allunimum lug 100 kva tf , supply of allunimum lug 250 kva tf , supply of allunimum lug 400 kva tf , safe carriage of pcc 8.5 m pole , safe carriage of st pole 9 m pole , safe carriage of st pole 11 m pole , safe carriage of 25 kva tf , safe carriage of 63 kva tf , safe carriage of 100 kva tf , safe carriage of 250 kva tf , safe carriage of 11 kv pin insulator , safe carriage of 11 kv disc insulator , safe carriage of 11 kv disc fitting , safe carriage of 11 kv fuse set , safe carriage of earthing , safe carriage of lt ab cable , safe carriage of lt xlpecable , safe carriage of acsr weseal conductor , safe carriage of lt pvc armoud cabler , safe carriage of distribution box , safe carriage of stay set complete , erection of pcc pole 8.5 m single support , erection of st pole 11 m single support , erection of st pole 9 m single support , erection of pcc pole 8.5 m double pole , erection of st pole 11 m double pole , laying sagging of weseal conductor , laying sagging of lt ab cable , laying sagging of lt xlpecable , laying sagging of lt pvc armoud cable , laying sagging of lt pvc cable , erection of plinth 250 kvatf , providing and installation of fancing , erection of pipe earthing , mounting of 25 kva tf , mounting of 63 kva tf , mounting of 100 kva tf , mounting of 250 kva tf , erection and grouting of stay , erection of stone pad , fixing of barbed wire , fxing of danger board , fxing of number plate , erection of earthing complete , erection of 3 phase distribution box , erection of dead end clamp , erection of prc connector , erection of 11 kv fuse set , erection and installation of lailless unit , received back material of 10 and 16 kva tf , received back material of 100 kva tf , received back material of lt ab cable
Tender For procurement of materials for repair of various components used in the fixing of light poles installed across of the failure different wards within municipal area - 61.13 p/l of double wall corrugated hdpe pipe confirming to is 16205 p-24, stiffness class 750 n, externally corrugated and having smooth surface inside with hdpe coupler, elbow, tee at required depth below the ground for layingcable of following nominal outer dia. mfr test report from nabl accrediated is to be submitted. (excavation of earth & back filling with compaction is to be paid extra) all as per pre approved by engineer in-charge.. for additional technical parameters of products/ work, refer annexure "a" attached with this bsr 50mm dia. , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured copper cable confirming to is:1554 p-i / is:7098 p -i of 1.1 kv with electrolytic grade copper made of copper rods confirming to is 613-1964, of purity >99.7%, inner/outer sheath confirming to is:5831 in existing rcc/hume/stoneware / pvc pipe/open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size. oem must have it's own in house nabl accrediated laboratory for testing procedure as per is:10810 for additional technical parameters of product / work refer annexure 'a' attached with this bsr 3 core , supplying and making one end termination with nickel plated heavy duty brass single compression gland (as per is 12943-1990)) sibg type consisting of check nut, gland body, metal washer(3 nos.), outer seal rubber ring, compression nut, heavy duty aluminium lugs (as per is 8309-1993) duly crimped with crimping tool, pvc tape as per is 8337-1976 of following size of pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required.all as per pre approved by engineer in-charge. for additional technical parameters of products/work, refer annexure "a" attached with this bsr 4 x 10.0 sq.mm pvc tape roll , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discom's specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure "a' attached with this bsr type a lt connector for aerial bunched cable each 73.00
Tender For sitc of vrv type ac - 14 hp air cooled outdoor condensing unit supply , 20 hp air cooled outdoor condensing unit supply , 24 hp air cooled outdoor condensing unit supply , 14 hp outdoor unit installation testing commissioning , 20 hp outdoor unit installation testing commissioning , 24 hp outdoor unit installation testing commissioning , 1.5 tr 4 way cassette indoor unit supply , 4 tr 4 way cassette indoor unit supply , 1.5 tr 4 way cassette indoor unit installation , 4 tr 4 way cassette indoor unit installation , 3 tr split dx cassette air conditioning system supply , 3 tr split dx ac system installation testing commissioning , centralized remote controller unit supply , centralized remote control unit installation testing commissioning , 25.4mm od copper refrigerant pipe supply , 22.2mm od copper refrigerant pipe supply , 19mm od copper refrigerant pipe supply , 15.86mm od copper refrigerant pipe supply , 12.7mm od copper refrigerant pipe supply , 9.5mm od copper refrigerant pipe supply , 25.4mm od copper pipe installation testing commissioning , 22.2mm od copper pipe installation testing commissioning , 19mm od copper pipe installation testing commissioning , 15.86mm od copper pipe installation testing commissioning , 12.7mm od copper pipe installation testing commissioning , 9.5mm od copper pipe installation testing commissioning , vrf refrigerant y and t joints with insulation supply , vrf refrigerant y and t joints installation testing commissioning , 3 core 2.5 sqmm cu shielded communication cable supply , 4 core 2.5 sqmm cu shielded communication cable supply , 2 core 1.5 sqmm cu shielded communication cable supply , 3 core 2.5 sqmm cu cablelaying , 4 core 2.5 sqmm cu cablelaying , 2 core 1.5 sqmm cu cablelaying , pvc condensate drain pipe with insulation supply , pvc condensate drain pipe installation , ms table top stands for outdoor units supply , ms table top stands for outdoor units installation , refrigerant gas r410a supply and filling , 4 core 10 sqmm xlpe armoured copper cable supply , 4 core 16 sqmm xlpe armoured copper cable supply , 4 core 10 sqmm xlpecablelaying testing commissioning , 4 core 16 sqmm xlpecablelaying testing commissioning , aluminium anodized partition for ac enclosure , light point wiring in pvc casing and capping , 2x2 led luminaire 24w recess surface mounted supply , led panel 2x2 24w installation testing commissioning , 4c 50 sqmm xlpe armoured copper cable supply , gi wire 8 swg supply and delivery , armoured cablelaying on wall for ac power db , 4c 50 sqmm cable end termination both ends , tpn distribution board 8 way hvac odu , fp isolator 125 amp sitc , fp mcb 63 amp sitc , fp mcb 40 amp sitc , sp and n distribution board 12 way hvac idu , dp mcb 32 amp sitc , sp mcb 6 or 10 amp sitc , sfu 100a tpn at main switch board sitc , chemical earth electrode earthing arrangement sitc , camc first year air conditioning system , camc second year air conditioning system , camc third year air conditioning system , camc fourth year air conditioning system , camc fifth year air conditioning system
Tender For work for shifting of electrical equipments from old crb to new crb and construction of new crb with boundary wall and other related civil work at raninagar ss switch yard under domkal division wbsedcl - dismantling of existing rtcc pnl from old crb and re-installation the same tyo new crb., removal of existing 1.1kv 4c x 2.5 sq. mm copper control cable from existing cable trenches and relaying the same to new cable trenches with all complete., removal of existing 1.1kv 8c x 2.5 sq. mm copper control cable from existing cable trenches and relaying the same to new cable trenches with all complete., removal of existing 1.1kv 12c x 2.5 sq. mm copper control cable from existing cable trenches and relaying the same to new cable trenches with all complete., re-installation of 30v,100 ah battery from existing crb to new crb, re-installation of 30v, 35 a automatic float cum boost battery charger from existing crb to new crb., re-installation of ac 3-phase 4w (1a) ct/pt operated amr. tri-vector 33 kv feeder meter from old crb to new crb., re- installation of a.c. 3 phase, 3w ct/pt operated amr. tri-vector 11 kv feeder meter from old crb to new crb, re-arranging for installation of data communication system including hardwares & cable with telephone modem, mri for all meters for 33/11kv sub-station having features for lan and remote connectivity along with supply of materials., relaying & dressing of existing healthy portion of 11 kv 3c, 300 sq mm xlpecable in the new cable trenches., laying of 1.1 kv 185 sq. mm 4c , pvc cable., laying of 1.1 kv 120 sq. mm 4c , xlpecable., laying of 1.1 kv 50 sq. mm 4c , pvc cable., laying of 1.1 kv 25 sq. mm 4c , pvc cable., laying of 1.1 kv 16 sq. mm 2c , pvc cable., laying of 1.1 kv 10 sq. mm 2c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 185 sq. mm 4c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 120 sq. mm 4c , xlpecable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 50 sq. mm 4c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 25 sq. mm 4c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 16 sq. mm 2c , pvc cable., making end termination joint including supply of cable lugs, glands, tapes , sockets etc of 1.1 kv 10 sq. mm 2c , pvc cable., re-installation of a.c. switch board from old crb to new crb., re-installation of d.c. switch board from old crb to new crb., dismantling of existing switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 4 panel (1in +0bc+3out) from old crb and re-installation the same to new crb., erection of switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 8 panel (2in +1bc+5out)., erection of switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 1 panel (0in +1bc+0out) (one buscoupler pnl along with adaptor), dismantling of existing switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 3 panel (1in +0bc+2out) from old crb and return to store in good condition., dismantling of existing switchgear (shunt trip) with vcb (12kv 350mva 1250/800a) 4 panel (1in +1bc+2out) from old crb and return to store in good condition., removal/uprooting & returning of different size of 1.1 kv pvc cable. qty taken l.s amount as not submitted by site office in the list of returnable materials)