Tender For construction of twin chamber acoustic material testing and uitility building including electrification for atf division, nwtc, belur campus, csir-nal, bengaluru - 560037
Tender For corrigendum : supply of shifting of secondary substation at workshop to frere basin compound - phase sequence testing and commissioning of ht cable , supply of straight through transition ht cable joint optional , making of ht cable transition joint pilc to xlpe optional , excavation of ht cable trench in soft soil or asphalt , ht cable trench excavation in concrete road optional , laying of ht xlpe cable 3cx240sqmm in excavated trench , laying of ht cable in rcc pipe or existing duct , supply of 200mm dia rcc pipe np2 class with collars , laying of rcc pipe and fixing of collars , supply of lt xlpe cable 3.5cx400sqmm to fp 6a , supply of lt xlpe cable 3.5cx400sqmm to fp 11 , supply of lt xlpe cable 3.5cx300sqmm to fp 1a , supply of lt xlpe cable 3.5cx300sqmm to fp 3 , supply of lt xlpe cable 3.5cx300sqmm to fp 4 , supply of lt xlpe cable 3.5cx300sqmm to fp 5 , supply of lt xlpe cable 3.5cx300sqmm to fp 6b , supply of lt xlpe cable 3.5cx300sqmm to fp 6c , lt cable trench excavation in asphalt paver area , laying of lt cable 3.5cx300 or 400sqmm in excavated trench , laying lt cable 3.5cx300 or 400sqmm in pipe or duct , supply of lt xlpe cable 3.5cx70sqmm to old cme building , excavation of lt cable trench for 70sqmm cable , laying of lt cable 3.5cx70sqmm in excavated trench , laying of lt cable 3.5cx70sqmm in rcc pipe or duct , cable termination material for 3.5cx70sqmm lt cable , cable termination installation for 3.5cx70sqmm lt cable , cable termination material for 3.5cx300sqmm lt cable , cable termination installation for 3.5cx300sqmm lt cable , cable termination material for 3.5cx400sqmm lt cable , cable termination installation for 3.5cx400sqmm lt cable , e-house foundation civil work , e-house shed supply and installation , rubble packing 250mm thick for cable trench reinstatement , stone metal 40-90mm layer for trench reinstatement , water bound macadam wbm layer for trench reinstatement , m10 grade rmc concrete levelling course , m40 grade rmc concrete road pavement , interlocking paver blocks 100mm thick , asphaltic macadam bitumen grade 60 70 regulating course , asphaltic concrete wearing course bitumen grade 60 70 , transporting surplus excavated material outside mbpa estate , dismantling of existing workshop substation equipment
Tender For supply of lab equipments - beesley s balance count : manual , overall dimension of unit : length x depth x height, 535mm x 140mm x 230mm 21 x 5.5 x 9 , net weight of the unit : 6.2 kg (13.6 lb), gsm cutter cutter type: circular, hand-operated cutting area: 100 cm ; blade : circular hardened stainless steel blade , water bath capacity : 400 ml x 12 pots; maximum temperature : ambient to 90 c; accuracy : 1 c; capacity (in liters) of main both : 25 liters (approx.); pot size : inner dia. : 79 2 mm; length : 122 mm; temperature controller : digital, pt 100 sensor ( 0.1 c accuracy); heater capacity : 3000 watts; bath size : 675 x 235 x 160 mm; power supply : single phase 220vac @ 50hz; consumption : 3050 watts; s ize(wdh) : 1100 x 350 x 250 mm; weight : 25 kg , crock meter rubbing finger shape: cylindrical; diameter: 10 0.1mm; diameter: 10 0.1mm; force: 9 0.2 n; stroke length: 100-110 mm; direction: straight line , back and front , hygrometer measurement range: 20- 80 %rh; accuracy : 2% rh; temperature measurement range: 20 - 30 c; sensor type: capacitive humidity sensor; response time 30 seconds, twist tester gauge length : 2 to 20 inch (5 to 50 cm); counting system : direct result; in-built calculations; readout in dot-matrix display; control system : microcomputer based pre-selectable / pre-programmable solid-state circuitry control user-friendly menus with membrane keypad assembly; programmable parameters : measurement unit, sample length & type, twist direction and speed index, etc.; elongation setting range : - 10 to + 100 mm; tensioning range : 1 to 90 grams (by calibrated augment weights); power supply : single phase 220vac @ 50hz; consumption : 100 watts; applicable standard(s) : astm d1422 / d1423 and is 832; physical dimensions : size (wdh) : 1000 300 200 mm; weight : 12 kg; swift/wheel circumference : 1.5 yards or 1 , yarnappearanceboardwinder tapered board : 01 no. parallel board : 01 no; main unit : 01 no. bobbins holder stand : 01 no., crimp tester measuring length : 60 cm; tension weight : 35g; net weight of the unit: 5 kg., thickness gauge measuring range : 0.010 to 10.00 mm measuring accuracy : 0.01 mm (or) 10 microns readability : 0.01 mm; diameter of anvil : top : 75 0.2 mm physical dimensions : size (wdh) : 150 110 160 mm; weight : 4 kg (accessories included) , wrap reel meter number of leas made at a time : 10 spread of each lea : 20mm 5 counter (three digits) : digital pre-set counter with sensor operating speed : 100 5 rpm motor : 1/8 hp 230v geared motor
Tender For providing and supplying modular furniture for newly constructed government school building at kachigam, nani daman. - civil works, providing supply and installation of corner sink table -size :-1100mm l x 1100mm d x 900mm hconstruction : floor based welded cabinet system having storage body should be flush face construction with intersection of vertical and horizontal members like lh and rh side panel along with front horizontal channel, back panel and bottom panel. it should be relocated anywhere easily as it is an independent unit. cabinet should of square non-sharp edge construction. doors should be assembled with ss-304 hinge assembly. removable back panel should be provided to easily access the service lines running behind the cabinet benches. intermediate horizontal channels should be provided between door and drawer. toe-space of 90mm x 90mm is provided at front-bottom side of cabinet. levelers are provided for easy leveling of welded cabinet. shelf should be eight-bend panel with 20mm height. drawer tray should be of single piece construction. drawer should be well supported on lh and rh ball slide suspension system. steel door and drawer front should be of double wall construction with sound dampening material filled inside. doors should be easily removable and hinges should be easily replaceable. knee space panel should be in 22 gauge , cabinets are tested as per sefa 8m standard from a sefa approved lab and also tested as per en 14727 from a third party testing agency having nabl accreditation. dimensions : w= 900 mm, d = 900 mm, h = 875 mm configurations: 1 shutter - 1 nos moc: mscrca: is 513 (1994) thickness: lh/rh side panels, shutter front, bottom panel, top front, drawer separator, shelf, alignment channel is of 1.2mm thk. removable back panel, shutter cover, fr. rack strip, top cover panel is of 0.8mmthk. finish: powder coating pure epoxy, thickness 40-50 microns , followed with 9 tank pre treatment process the thickness of powder coat should be 45-50 microns, which passes the test of salt spray for 1000 hours. it should have a high temperature withstanding capacity with excellent electrical insulation properties.the rear portion of above accessories which is in contact with live metal should be made from thermo set material which will not melt on heating.handle : anodized aluminum recessed-type, ctc: 160.0mm lock: units have a locking facility with 180 and 10 lever cam lock mechanism (except for sink and corner unit) hinge: ss hinge screw: ss 304.shutter : should be of twin-type construction with sound dampening effect using profill.shutter cover should be equipped with bump on for sound dampening. base moulding should be made of pvc with corner clips. ball slide: 500mm length shutter should have provision of roller catch.pp sink,polypropylene molded sinks: made up of 5 mm thick high density and elastic poly propylene with good resistance to organic solvents. sink - bowl size to be a minimum of (l x w x d) 560 x 355 x 300 mm.faucet - 3-way type faucet as per approved makeworktop : jet black granite: it should be 19mm (+/- 2mm) thick jet black granite worktop. the exposed edges of the worktop should be chamfered and smoothened. the bottom of the worktop should be polished and there should be a v-groove throughout the length of the exposed edges to protect the cabinets from coming in contact with the spillages. the overhang on the storage cabinet is 25 mm at the front side and 30 mm at the sides. the backing material used is a neoprene mat of 6 mm thickness. (make as per selection of architect or selection of higher authority), providing supply and installation of corner table - size 1100mm l x 1100mm d x 900mm hconstruction: floor based welded cabinet system having storage body should be flush face construction with intersection of vertical and horizontal members like lh and rh side panel along with front horizontal channel, back panel and bottom panel. it should be relocated anywhere easily as it is an indepe
Tender For bid to ras corrigendum : tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables