Get complete information related to latest Zonal Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Zonal Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Zonal Work Tenders.
Tender For repairs and maintenance under special zonalwork for change of occupation of quarters under jurisdiction of sse(w)/colony-ii and iii at clw, chittaranjan.
Tender For repairs and maintenance under special zonalwork for change of occupation of quarters under jurisdiction of sse(w)/colony-i (inclusive area of zone 1/a, 1/b, 1/c) at clw, chittaranjan.
Tender For supply and erection of 15 feet gi pipe of 100 mm dia 4.5m thickness of medium quality isi no: 1230(part 1) 1990. having an iron base plate 10 mm thick x 30 cmx 30cm welded at the bottom of the pipe with four supports of iron bars of sizes 10 mm dia. the 3 feet pipe shall be buried in the ground and 12 feet shall be. above the ground. the work includes digging of the pit on platform, laying of cable in between poles in suitable underground gl pipes, erection of pole and filling the pit with 1:3:4 cement, concrete and sand. final plastering should be done on the surface. the iron bracket on the top of the pole shall be provided to fix the cctv camera, protection cover and junction box. the work includes supply of all the materials required in this item. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : the items mainly included in the estimate are rust proofing processes chipping of unsound concrete cleaning of reinforcement applying bonding coat, applying sbr polymer for the rcc water tank 9 mm plastering of top slab of rcc water etc
Tender For corrigendum : repair to joinery tiling sunken slab chajja roof projection flooring plastering and miscellaneous connected work etc outside depot area at a a banar under ge banar
Tender For corrigendum : repair to joinery tiling sunken slab chajja roof projection flooring plastering and miscellaneous connected work etc inside depot area at a a banar under ge banar
Tender For corrigendum : special repair to tiling, plastering, joinery and internal wiring at anteroom, bed room and dinning room at building no p-12 mb area and certain rev and minor work in the area of age b/r-i under ge (west) jabalpur
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get