Get complete information related to latest Air Conditioners Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Air Conditioners Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Air Conditioners Tenders.
Tender For repair and maintenance of various dia water line network/distribution system and attending of day to day complaints of leakages, contamination and no water in sangam vihar ac-49 under ee(c)-32
Tender For corrigendum : tender for providing installation testing and comissioning of various capacity split acs to avoid overheating of electrical distribution boards & sensitive electrical components at 33/11kv s/stn jabli feeding to aiims hospital and nearby areas & 33/11kv s/stn beri in electrical section jabli & beri respectively under electrical sub- division hpsebl no.iii & no.-i, hpsebl, bilaspur. (ts no. 26/2019-20 wbs no. d-19-1339)
Tender For corrigendum : supply of condenser assembly for subros make emu/memu driver cab 2.0 tr tower type airconditioner unit. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs c-428; e031 low cooling effect observed in ac plant due to scale formation and mud particles accumulated in condenser tubes of condenser no 2 chemical cleaning of ..
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - 88 acv sqn (h-188 & h-193); undertaking engineering jobs onboard 88 acv sqn (h-188 & h-193); service provider
Tender For corrigendum : repair, replacement and cleaning of sewage system including miscellaneous connected item in otm accn area of age b/r-i under ge gwalior
Tender For repairing replacement of internal wiring fitting and fixture and various type of led fitting and connected earthing items at domestic area at af stn naliya - materila and labour for point wiring with 1.5 sq mm frlsh single core pvc insulated unsheathed 1100 v grade with multistranded copper conductor drawn through pvc casing and capping with all accessories fixed to wall froofs ceiling etc and incl provision of 1.5 sq mm pvc insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including pvc box isi marked of suitable size for mounting the switches, socket outlets, fan regulators etc., complete all as specified and directed for following:- one light/fan point controlled by one switch. one socket 3 pin outlet 5 amp on independent board. one light point controlled by two 2-way switches. one 3 pin socket outlet 5 amp on the same board with other switches. one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. all as per serial item number 2.00 here-in-before but with copper conductor cable of 2.5 sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor. supply and fix in replacment of switch piano flush type single pole one way 5 amp, complete all as specified and directed. supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. supply only socket outlet multipurpose 213 pin 5 amps flush button type with universal box in polycarbonate complete all as specified and directed. supply only switch socket multipurpose 2 in 1,5 and 15 amps complete all as specified and directed. supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed. supply only switch bell push, flush type 5 amp. supply only electric bell ding-dong ac 230 volt sp with brass screws and cup washers all as specified and directed. pa supply only hylem sheet 3 mm thick size 9" x 11" including cutting of switch,socket complete all as specified supply only hylem sheet 3 mm thick size 8" x 5" including cutting of switch,socket complete all as specified supply only mcb single pole and neutral 32-63 amps, 240 volts, complete all as specified and directed. all as per item ser no 60 above but with two run of single core 6 sq mm and one run of 6 sq mm frlsh as earth wire s&f in replacement of 9 watt led bolard lights 4300/6500 k in rectangular shaped victorian design with opal acrylic diffuser and ip 65 protection,including pcc work for mounting the fittings with suitable size of nut, bolts and connection with two core copper cable all as specified and as directed. make bajaj, havells, crompton. m&l for repair / maint of wooden/steel boards for electrical db of any type and size including replacement of doors as per site requirement, hinges, handle and locking arrangement with necessary welding works, wooden works to make good the wooden / steel boards including painting with synthetic enamel paint of one coat all etc complete. the quoted shall be inclusive of replacement of wooden doors! steel doors/hinges! locking system/welding work required for repair/fixing of new doors etc complete pac s&f in replacement of 36w led recessed 2x2 luminaire 6500k fixed in the existing ceiling/roofs white powder coated crca housing with led seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size in kutch auditorium with ceiling height of more than 20 feet including necessary arrangement for scaffolding ladder for replacement of ceiling lights all as specified and as directed. note: the quoted rates are inclusive of necessary safety arrangements iscaffolding/ladder etc complete all as specified and directed
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee