Get complete information related to latest Channel Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Channel Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Channel Work Tenders.
Tender For construction of boosting station in bhutia pana near old chopal, raw water inlet channel and strengthening of existing s and s tank no.2, providing and laying distribution system
Tender For construction of drain and soak pit tank for waste channelization in village dadhogi, tehsil arki, distt. solan g.p. dadhogi mohal) dmft deposit.
Tender For corrigendum : dn/mas acting for and on behalf of the president of india invites e-tenders against tender no m-sg-2026-515-ms_vm-2 closing date/time 03/07/2026 15:00 hrs. bidders will be able to submit their original/revised bidsupto closing date and time only. manual o ers are not allowed against this tender, and any such manual o er receivedshall be ignored.1. nit headername of worksignalling and telecom portion of work in connection withengineering works in chennai beach(msb)-villupuram(vm)section overchennai division.(msb-vm-2026-2)bidding typenormal tendertender typeopenbidding systemsingle packet systemtender closing datetime03/07/2026 15:00date time of uploadingtender09/06/2026 16:19pre-bid conferencerequirednopre-bid conference datetimenot applicableadvertised value 14550242.18tendering section signalbidding style[ decision at schedulelevel ]bidding unitearnest money (rs.) 291000.00validity of offer ( days) 60tender doc. cost (rs.)0.00period of completion 12 monthscontract type works - general contract category expenditurebidding start date 19/06/2026are jv allowed to bid nonumber of jv memberallowed0are consortium allowedto bidnonumber of consortiummember allowed0ranking order for bidslowest to highest expenditure typecapital (works)2. schedules.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () a-sor 2022 items9145422.44above/below/par1please see item breakup for details. 9145422.44 at par9145422.44description:- sor 2022 itemss.no. itemcodeitem qtyqty unitunit ratebasic value escl.(%) amount biddingunitschedule () b-non sor items5404819.7411 3900.00numbers 100.00 390000.00 at par 390000.00 rs.description:- provision of 7.2 mm holes in old/new rails to provide continuity bonding /polaritybonding etc (all other material required for the work shall be supplied by contractor) (this scheduleincludes the xing of bond wire in the 7.2 mm hole). the bond wire and channel bond pins will besupplied by railways)22606.00numbers 670.00 406020.00 at par 406020.00 rs.description:- releasing and re xing of tld boxes in dc track circuits. (this work includes releasingthe existing track connections and reconnecting the track connections after the completion of workalong with provision of necessary holes for connecting lead wires and painting of track particulars.all the materials required for the above work shall be supplied by the contractor as per the directionof the rly engineer at site.3360.00numbers7400.00 444000.00 at par 444000.00 rs.description:- re xing of released point m/c (all types) and its gound connections (existing pointmachine) including wiring and termination in point m/c and interconnections between point m/c andct box through pvc hose pipe and painting (all types of insulations connected to point work , alltypes of bolts and nuts, washer springs/ at , pvc hose pipe, 3/0.75 sq.mm copper wire,7/1.4 sq.mmcopper wire, paints and other miscellaneous items shall be supplied by the contractor). the workshall be carried out as per the instruction of engineer at site.4110.00numbers3600.00 396000.00 at par 396000.00 rs.page 1 of 16run date/time: 09/06/2026 16:19:30chennai division-s and t/southern rlytender documenttender no: m-sg-2026-515-ms_vm-2closing date/time: 03/07/2026 15:004description:- releasing and re xing of cable termination box for point machine (existing pt ctbox)- this work involves breaking of concrete andreleasing the existing cabletermination box andkeep it a side casting of foundation and erection of the released ctbox and carrying out the interconnection between point machine and ct box. the work shall be carried out as per the instrution ofengineer at site.55141.00numbers3771.78 531820.98 at par 531820.98 rs.description:- all type point machine ground connections to be released carefully withoutdamaging, kept aside and re- x the same after completion of engineering work. the work shall becarried out as per the instruction of engineer at site.66 8000.00numbers 5.70 4560
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For repair/replacement of external electric supply distribution network with other connected items at malad, marve and kandivali under ge (n) santacruz, mumbai - supply, install, testing & commissioning pedestal cubical type double door lt bus bar chamber box of suitable size factory made modular construction fabricated out of 3 mm thick crca sheet, angle iron, channels, epoxy powder coated to give a superior finish , outdoor type , totally enclosed dust & vermin proof with locking arrangements front & back side opening system including rain shed, busbar chamber should be suitable for accomodating all aluminium bus bar strips (50mm x 10mm x 04 nos) & gi strip for earth fixed on porcelain insulators, and one independent metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom part, with fixing arrangement on pcc (1:3:6) type c-2 bed block with studs, bolts, nuts & washers, danger notice board with scull suitable for 415 volts or required size to be fixed on pannel including dismantling of old bus bar panel all as specified and directed by engr-in charge.notes:-(a) aluminium bus bar duly covered with colour coded shrinkable sleeves of required size for phases and neutral - 01 set(b) mccb 4 pole , ics=100%icu- 25 ka, 415 volts, 100 amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 nos.(c) digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch and programable ct of appropriate ratio.-01 no make- imp/automatic electrical(ae)/ l&t / havells/ meco(d) panel indicating lamp neon/led type (red ,yellow & blue) with lamp holders - 03 nos(e) panel instrumental wiring with frls suitable size but not less than 2.5 sqmm copper wire single core - 01 job(f) necessary sizes of lugs for fixing of cables in bus bar deemded to be included rate quoted by the contractor.make of mccb & mcb: larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 400 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:- larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 160 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 16 ka 100 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb, all as specified and directed by engr-in-charge. make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supply & fixing mccb 4 pole 36 ka 250 amp with adjustable thermal & adjustable magnetic setting, including taking down old unserviceable mccb all as specified and directed by engr-in-charge make:-larsen &toubro/ abb/ siemens/ schneider/ havells/ legrand/ indo asian/ c & s electric/ bhartia cuttler hammer (bch)/benlo, supplying, laying,connecting, testing & commissioning lt ug pvc insulated, heavy duty, 1100 v grade electric cable with aluminium conductor of size 16 sqmm x 4 core, laid in trenches or passing through pipe or fixed to wall, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by engineer-in-charge of following sizes:-note : earthwork excavation, dwc
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For repair/replacement to doors, window, ventilators, cupboards, flooring/ plastering, tilling and other miscellaneous joinery /sanitary items at af stn aastha complex, 5 aflu under aor of ge (af) faridabad - demolition/dismantling of brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed., m&l for brickwork with subclass b bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed., all as per item no 02.00 above but except bricks., m&l for brick work with sub class b bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete all as specified and directed., taking down cement plaster of any description on concrete surfaces such as soffit of rcc slab, chajjas and brick walls, ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed., m&l for rendering 15 mm thick cement plaster in cm 1:6 on brick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed., m&l for rendering 15mm thick in cm 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl wpc as per user manual complete all as specified and directed., m&l for rendering 10mm thick in cm 1:3 over concrete surface as on ceiling, chajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m&l for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., taking down chowkhats or frames with shutters not exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down chowkhats or frames with shutters exc 1.5 sqm but not exc. 4 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down shutters of any description n exc 1 sqm each complete all as specified and directed., taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed., s&f for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed., s & f solid pvc door frame of size 50 x 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube incl taking down old frame any type complete all as specified and directed., s&f factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of ms tubes for top & bottom rails ms frame shall be convered with heat moulded plain colour pvc `c channel having a pvc sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour pvc sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain c
Tender For corrigendum : laying of pvc pipe channel 160 mm o/d 4kg/cm2 including haudie, repair of existing s and s tank 1 no. size 123.00 x 93.00 x 0.76 mtr, rcc s and s well 2.0 mtr dia, new pump chamber 6.10x4.88 m, repair of existing 4 nos filter bed 9.00 mtr dia,