Tender For annual comprehensive maintenance contract of split rac and 6 body mortuary chiller air-conditioning machine installed under various site of islampur electrical sub-division. (for one year)
Tender For repair and maintenance of ei to auditorium building dr.rpgmc kangra at tanda (sh- replacement of 400 amp mccb of chiller plant and main stage lighting pilot thereof)
Tender For supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25 mm dia , sitc
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - government building, up-112 hq; repairing of 02 cooling tower and 01 chiller; service provider
Tender For nhm setting up of post operative icu laproscopic surgery unit and construction of mortuary at taluk head quarters hospital vythiri in wayanad district composite work
Tender For supply of calibration of equipment and machine - shore a hardness tester , electronic balance , reversion test apparatus , vernier calliper , measuring tape , steel scale , micrometer ball point analogue , micrometer analogue , micrometer digital , micrometer ball point digital , muffle furnace , cold chamber , vicat softening point test apparatus , oxidation induction tester , oxidation induction tester flow meter of o2 , oxidation induction tester flow meter of n2 , carbon black contents test apparatus , carbon black contents test apparatus flow meter of n2 , melt flow index apparatus , digital thermo hygrometer , digital humidity chamber , environmental chamber , hydraulic press tempareture controller , glass thermometer , bursting strength tester 1 , bursting strength tester 2 , digital stop watch , std calibration glass tube for bendsten smoothness and porosity tester , standard reference gloss tile , gloss meter , standard reference brightness tiles , brightness opacity and colour test apparatus , electronic reflectance meter , paper thickness apparatus dial indicator , thickness micrometer digital , folding endurance tester , digital temp. controller with sensor for water bath , hydrostatic pressure test apparatus 02 stations , hydrostatic pressure test apparatus 04 stations , irhd hardness tester digital dial gauge , colour matching cabinet , counter meter pilling test apparatus , digital temp controller with sensor j type launder o meter , bench type thickness gauge , weight perspirometer , tensile strength tester , tensile testing machine , universal testing machine , crock meter , multi cell ageing oven , toe impact tester for safety shoes , sole adhesion tester , sole leather grain crack tester , water vapour permeability tester digital timer , heat insulation tester digital temperature cont. cum indicator with sensor , heat insulation tester digital temperature cont cum indicator with sensor , leakage proofness tester dial pressure gauge , leakage proofness tester digital timer , cold ross flex tester digital temperature controller , bally water penetration tester , digital temperature controller in deep freezer cold insulation tester , bally flexometer tester dig counter meter , veslic rub fastness tester dig counter meter , din abrasion tester dig counter meter , martindale abrasion tester dig counter meter , full shoe flex tester dig counter meter , bennewart flexometer dig counter meter , bata belt flex tester , shoe lace to eyelet abrasion tester , resistance to hot contact dig temperature controller cum indicator with sensor , blade cut resistance tester , de mattia flex tester , low temp vamp flex tester , velcro fatigue tester , steel plate flex tester , water absorption and desorption permometer dig timer , dynamic water resistance tester , fibre board flexing tester , ankle protection tester , compression cum nail penetration and energy absorption for seat region , digital lastometer , rigidity tester , precision thickness micrometer , slip resistance tester for shoe
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; repair/replacement of air-cooled scroll chiller type cooled central ac plant of capacity (2*11 tr & 1*11tr ) at parachute and central ac plant capacity (2*..
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - office space; repair/replacement of air-cooled scroll chiller type cooled central ac plant of capacity (2*11 tr & 1* 11tr ) at parachute and central ac plant capacity (2..
Tender For corrigendum : tn-5418 operation and maintenance of air conditioning system including central ac system, package air conditioners, evaporative cooling plant, hydrogen dryer, cooling tower for ac system and repair and reconditioning of condenser/chiller of kstps, k