Web Analytics Made Easy - StatCounter

Coil Tenders

Get complete information related to latest Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Coil Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45467370 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : supply of 5 core 4 sq mm multi strand copper trailing cable, 1100 volts grade. , 4 core, 16 sq.mm, frls aluminium, xlpe insulated, armoured, 1.1kv grade. , analog timer for hmt. analog timer. , 50 a,4 pole power contactor with coil-complete set. , 4 pole 63a mcb.

Corporations/Associations/Others

CTN :45723888 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supplying materials for maintainance in water supply department for fy 2026-27 (as per daily requirement)- gi pipe (class b, isi marked), gi bend (class b, heavy, isi marked), submersible gi coupling (heavy class, isi marked), gi reducing socket (heavy), pvc pipe (6 kg/cm²), pvc pipe (25 kg/cm²), pvc pipe (10 kg/cm²), ci flanged valve (heavy), pvc fta (10 kg/cm²), pvc bend (6 kg/cm²), pvc reducing socket (heavy, 6 kg/cm²), ci df sluice valve (isi 780-1994, heavy duty), ci detachable joint (complete set), nut-bolt, pvc solution (kisan), packing rope, acc pipe (class 15, isi marked), ci pipe (la, isi marked), ci special fittings (isi marked), rubber sheet, lead, air valve (isi marked, 25 mm), ci saddle piece (150 mm & 25 mm), gate valve (heavy), pvc tee, gi nipple, pvc saddle, pvc elbow, nylon rope, torch, holiday daba, greece, lokhandi angle bar and strap, g.i.lokhandi chaddar, g.i. miter box, air duct, motor pipeline pressure clock, air whale middle ball, hose pipe, hose nipple, pvc end cap, football, football jeep, air wall cdm , p.v.c.m.t.a., g.i. coupling, pungali pana sat, alanki pana sat, ring and fit pana sat, screw nut, die frame, dye gulps, saw frame lokhandi, saw blade, hand drill machine, hand drill machine electric, drill machine beat, voice, water body and haat pampachi full body fitting, hand pump connecting rod, hand pump chain, hand pump upper wall set, hand pump socket, hand pump handle, hand pump head, hand pump bearing, hand pump reducer cap, hand pump bucket wiser, hand pump globe whale, hand pump axle pin, hand pump wiser, hand pump rubber titan, hand pump water tank, hand pump cylinder, g.i.pipe b class, lokhandi road, spindle, motor pump starter & material 3 phase motor pump company texmo aquatax helen openwell submersible motor pump, openwell monoblock motor pump, borewell submersible, 1 phase motorpump openwell submersible motor pump, openwell monoblock motor pump, starter, ltlk relay range, ltl timer coil and timer assembly, ltl insect point pocket, ltl relay 4 to 33, l.t.l.m.n.releche plastic button, ltl starter button knob, ltl simple, water sill, submersible motor bearing fiber cap, submersible bush, , , , old meter and ampere meter, old and ampere meter box compliant, monoblock motor pump coupler rubber bush, , , , , condenser capacitor mfd, , , , , , , , , , single phase auto switch lcb ampere 16 to 20, 3 phase auto lcb 17 to 20, 3 phase e.l.c.d. ampere 16 to 32, capacitor, , , , , , ltl auto switch 200 amps, wire, , , , , , , cable, , , , auto wire bundle, kit kat, , , , , , switch khosla 15 amp, plug khosla 15 ampere, pvc tape roll bundle, water supply joint tape roll bundle, rubber gasket 3'' 4'' 6'', everyday sale daba (20 nos.), g.i. tap, , , , snoring, wire brush, c.i.pipe, , , , , c.i.mechanical bend, , , , , c.i.mechanical t, , , , , p.v.c. adapter (tail piece), , , , , si. income. mechanical joint, , , , , tikas danda, spade stick, plastic bucket, lokhandi bucket, rubber titan, rubber gasket, g.i.wire, g.i.elbow, , , , , g.i.union, , , , , plasto syntex talkie, 4 coats with finish, , , , finolex pipe, , , , , , , , water meter, , , ferrule plate, , , , control panel star delta 14 to 31 amp, control panel single phase 5 to 21 ampere, m.sil. packet 100 grams, bean coke, monkey pliers, cannes, , , pvc m.t.a., , , , , , , , , , , lokhandi vicere, rabari vicere, rubber titan , get pipe range, , , , , , nut bolt 4 sut x 3'', nut bolt 4 sut x 5'', g.i. nipple, , , , , , , , , , , lock, small per piece, big per piece, getting a bandage, , , , , , , , , , , find peace, , , , , , , , , , , , , , g.i. elbow, 1 inch, 1/2 inch, 3/4 inch, 1 1/2 inches, 2 1/2 inches, 2 inches, 3 inches, 4 inches, 5 inches, 6 inches, ,-s.t.m. pipe, , , , , , e.s.t.m. tea, , , , , , e.s.t.m. elbow, , , , , , , , , , , , e.s.t.m. reducer, , , , , , e.s.t.m. brass threaded tee, , , , , , e.s.t.m. brass threaded elbow, , , , , , e.s.t.m. brass threaded socket, , , , , , e.s.t.m. brass threaded reducer, , , , , , ,p-m

Central Government/Public Sector

CTN :45731769 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For supply of 2 x 1.5 sq.mm multicore screened, thin walled electron beam irradiated flexible elastomeric cable with copper conductor suitable for rolling stock application generally conforming to edts-132, rev-c, amd-1, 2 & 3, data sheet-4, 600v grade.the colour of the outer sheath shall be black and colour of cores shall be brown & white. note: 1) approved sources of multi core cables to specn.no. clw/es/0459. as per rdso approved vendorslist shall only be considered. 2) cables shall be supplied in coils of 500 meters length and leftover quantity in multiples of 100 meters with a tolerance of+/- 5% on the length. [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45732697 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For repair of 50 hp controlo panel including new 70 amp contactor and labour charges complete in all ,respect job / at mps for village talao, kheri khumar ,over load coil / at mps for village talao, kheri khumar. /50 watt / at mps for village talao, kheri khumar. ,copper gutka / at mps for village talao, kheri khumar. ,fuse wire roll / at mps for village talao, kheri khumar.

State Government

CTN :44231929 Due date: 13 Jul, 202613 Jul, 2026 NA
Tender For corrigendum : supply of various consumable material at emd -1 lighting dept. stps. - flat cable 3 corex4 sqmm with copper conductor for submersible motor, flexible copper wire 1 corex2.5 sqmm (36/0.3 mm)1100v(1 coil is equal to 90 meter), flexible copper wire 1 corex1.5 sqmm (22 / 0.03) voltage grade up tp 1100 volt conf to is- 694, copper cable 2 cx1.5 sqmm, pvc twin wire 2.5mm sqr., self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of red colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of yellow colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of blue colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of black colour, self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm width x 7.5 mtr length x 0.125 mm thickness, of green colour, porcelin kit kat fuse 16 amp, porcelain kit kat fuse 63 amp, 415 v , ac, porcelain kit kat fuse 100 amp, 415 v , ac, porcelain kit kat fuse 200 amp, 415 v , ac, din rail mounting channels, ring spanner set model 1812 taparia make, double ended spanner set dep 12, adjustable screw spanner size 8" (200 mm) p.no.1171-8 p, screw driver (tester) taparia product no: 818.special with neon bulb, generally confirming to is 5579-1985 grade - ii, yellow handle,, taparia combination plier, product no.1621-8,210 mm, digital insulation tester, range-0-2000 m-ohm, selectable test voltage-250/500/1000 v dc with rechargeable battery, digital clamp on meter lcd display with backlight, 3-3/4 digit., alluminium ladder self supported a type having 05 feet length, long nose plier insulated with thick c.a. sleeve,165 mm length, taparia make tool, allen key set, product no aki 10, allen key set mm size (09 piece) 1.5,2,2.5,3,4,5,6,8,10 mm, hand drill machine size 13mm, hand grinder machine., aluminium tube terminals10.0 mm2, m.6, aluminium tube terminals16.0 mm2, m6, aluminium tube terminal 35 sqmm,m 8, aluminium tube terminals50.0 mm2, m10, aluminium tube terminals70.0 mm2, m8, aluminium tube terminals95 .0 mm2, m10, pin terminal 1.5 mm2, pin terminal 2.5 mm2, aluminium in line connector25.0 mm2,, 35mm alluminium in line connector als-2"dowell", aluminium in line connector 70 mm2, 95 sqmm crimping alluminium type in-line connectors cat no: hai-15 hex make, crimping tools capacity: 10 mm2 to 185 mm2., crimping tools, capacity: 6 mm2 to 50 mm2., alluminum ring type lug 25 sq. mm, pvc saddle 10 mm, pvc saddle 15 mm, pvc saddle 20 mm, pvc saddle 32 mm, multistrend copper flexible wire 1 core x 4.0 mm2, (7 strendes) pvc (double) insulated, without armourr, 1.1kv grade (100m/coil)

Central Government And Public Sector

CTN :45733103 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For auction sale of others - 1. gear case half-11 nos 2. brake shoe nominal- 750 nos. 3. brake shoe l type- 240 nos. 4. axle box -11 nos. 5. bearing felt cap half-10 nos. 6. locally fabricated coil spring test stand-1 no. 7. brass suspension bearing- 21 nos. approx weight-7132.9 kgs. (fe-6786 kgs, nf, brass-346.9 kgs) total qty-1044 nos.

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

Central Government/Public Sector

CTN :45713851 Due date: 25 Jul, 202625 Jul, 2026 55.00 Lacs
Tender For repair/maint of air cooled ac plants, chiller, condenser pump, hot water boiler, ahu, water colled ac plants, motor, hwg and ahu alongwith connected items at akash complex/tech area at dappar under age(i) dappar - material and labour for servicing / cleaning of air cooled ac plants of 50 tr capacity, chiller unit, cleaning and washing of cooling coil with fins using a chemical c-shine (alkaline coil cleaner and brightener) and testing the unit (once in a three months) complete all as specified and as directed by engineer-in-charge. location :- akash air cooled ac plants(once in a three months), material and labour for descaling of complete condenser units for central/ package type ac plants of condenser unit of water cooled ac plantac plant upt to 40 tr capacities by means of adding descaling chemical solution (hcl) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and refixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc. to entire satisfaction of engineer-in-charge complete all as specified and as directed by engineer-in-charge. location :- old, 3ac igloo ac plant and new ac plant (once in a three months), material and labour for cleaning of cooling tower existing size, water basin and makeup tank with the help of chemical and nylon brush, removing and refixing of pvc finches after washing, cleaning of condenser pipe line ( inlet and outlet) including painting of out side of cooling tower with inlet and outlet pipe line with one coat synthetic enamel paint of colour approved by engineer in charge and inside painting of water tank of cooling tower using water proof black japan paint one coat including changing of unserviceable pvc guard, water distibutor, pvc pipe, and all connected minor items of up to 100 tr capacity of the ac plants at different locations complete all as specified and as directed. location :- old and new ac plant, material and labour for servicing of cooling coils and air filters of ahus intalled at air conditioning plant by removing air filters and fixing after cleaning with air blower and water and cleaning agent , cleaning of cooling coilwith wire brush and air blower and water spray pump after spraying scale gun or equivalant chemical suitable for aluminium fins and straighting the fins of cooling coil by using suitable brush for any capacity of ahu complete all as specified and as directed by engineer-in-charge. locaton :- new ac plant, old ac plant , 3 ac igloo ac and akash ac plants akash, material and labour for servicing / cleaning and testing of electrically operated pan type humidifier capacity 9 kw alongwith all necessary items fitting and all suitable / all necessary electrical wiring from electrical panle to humidifier complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in cold water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing / cleaning and testing of pressurization unit in hot water line ( psu-225 as per site) alongwith all necessary items fitting and all suitable / all necessary electrical wiring complete all as specified and as directed by engineer-in-charge. location :- akash ac plants, material and labour for servicing , cleaning , and greasing , chiller , hwg pumps , ahu and ct motors alongwith all necessary minor items/ fitting i.e bearing , star coupling , screws , nuts and bolts etc complete all as specified and as directed by engineer-in-charge. location :- new ac plant , old ac plant and air coole

Central Government And Public Sector

CTN :45617559 Due date: 03 Jul, 202603 Jul, 2026 5.63 Lacs
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva

Central Government And Public Sector

CTN :45617729 Due date: 03 Jul, 202603 Jul, 2026 5.66 Lacs
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
 Loading, Please wait...

Connect us via What's Up