Tender For supply of 2 point 5mfd ceiling fan capacitor , 3m plate make roma , 4m plate make roma , 6m plate make roma , 8m plate make roma , 12m plate make roma , 3m surface type pvc box make roma , 6m surface type pvc box make roma , 8m surface type pvc box make roma , 12m surface type pvc box make roma , 1m blanking platedummy make roma , 3pin 6a socket 2m make legrand , 616a 2in 1 socket 2m make legrand , 3pin 6a socket 2m make roma , 616a 2in 1 socket 2m make roma , 3pin 6a socket 2m make mk , 6a socket 2m make mk , 6 10a switch, 1m make roma , switch mk , switch legrand , 16 20a switch, 1m make mk , 16 20a switch, 1m make roma , 6pin 6a 16a ss combined with shutter and pvc boxmake anchor , 32a single pole c type mcb make legrand , 32a 2p c type mcb make legrand , 32a 3p c type mcb make legrand , 32a 4p c type mcb make legrand , 63a 4p c type mcb make legrand , 32a spn plug industrial socket and cap with metallic enclosure box suitable for ac make legrand , insulation tape , fischer plug suitable for 1 inch drywall screw , fischer plug , screw , 1ft 58w led cool white tube lightmake cromptonsyska equivalent , 2ft 14wled cool white tube light , cool white round led false ceiling light , 12w cool white round led surface mounting light , 18w cool white round led false ceiling light , 15w cool white round led surface light , 18w cool white round led surface light , 1m fan regulator make roma , 1m 4step 04fan regulator make legrand , 2m fan regulator makemk , exhaust ventilating fan makeorient model ventilator dx , telephone instrument , telephone instrument with caller id , 5inch pvc round sheet , thermostat solar water tank , 200w led cool white flood light , 56a 3pin plug top , 15a 3pin plug top , 9inch nylon selflocking cable tie , copper wire , dol starter make l and t bch electric , annealed copper telephone flexible unarmouredcable , aa duracell batteries , distilled water , handheld cardless microphones with 2mics in each and receiver with standard accessories , capacity empty oil barrel suitable for purchasing of diesel , rotary manual hand pump with dual direction , pvc casing pipe , pvc heavy duty conduit pipe , pvc casing heavy duty conduit pipe , mseal 90gm , steel clamp
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For repair/replacement to doors, window, ventilators, cupboards, flooring/ plastering, tilling and other miscellaneous joinery /sanitary items at af stn aastha complex, 5 aflu under aor of ge (af) faridabad - demolition/dismantling of brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed., m&l for brickwork with subclass b bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed., all as per item no 02.00 above but except bricks., m&l for brick work with sub class b bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete all as specified and directed., taking down cement plaster of any description on concrete surfaces such as soffit of rcc slab, chajjas and brick walls, ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed., m&l for rendering 15 mm thick cement plaster in cm 1:6 on brick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed., m&l for rendering 15mm thick in cm 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl wpc as per user manual complete all as specified and directed., m&l for rendering 10mm thick in cm 1:3 over concrete surface as on ceiling, chajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m&l for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., m & l for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed., taking down chowkhats or frames with shutters not exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down chowkhats or frames with shutters exc 1.5 sqm but not exc. 4 sqm each (without taking off shutters from the frames) complete all as specified and directed., taking down shutters of any description n exc 1 sqm each complete all as specified and directed., taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed., s&f for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed., s & f solid pvc door frame of size 50 x 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube incl taking down old frame any type complete all as specified and directed., s&f factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of ms tubes for top & bottom rails ms frame shall be convered with heat moulded plain colour pvc `c channel having a pvc sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour pvc sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain c