Get complete information related to latest Enviromental Chamber Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Enviromental Chamber Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Enviromental Chamber Tenders.
Tender For repair of polyhouses - renovation and repair work of existing polyhouses to maintain operational efficiency at icar-cith (for 17 polyhouses)
Tender For purchase of machinery/equipment for plastic and rubber trade for up-gradation of govt. quality marketing centre faridabad under trade infrastructure for export scheme(ties). - purchase of machinery/equipment for plastic and rubber trade for up-gradation of govt. quality marketing centre, faridabad under trade infrastructure for export scheme(ties)., computerized universal testing machine: 10kn (tensile/compression/ flexural strength measurements)., izod/charpy impact test (impact test measurements), digital shore a & d hardness testers (hardness measurements)., carbon black content apparatus (determination of carbon black content of plastics), ozone chamber (rubber or elastomers resistance to ozone degradation), hot air oven (heat resistance of rubber & elastomers)., muffle furnace (thermal characterization of plastics & rubber), rockwell hardness tester (hardness measurements), compression set apparatus (compression set characteristics of rubber), flammability tester (with accessories), climatic chamber, melt flow index tester (with automatic cutting facility and weighing scale), ultra violet (uv-b lamp) test apparatus, oil bath immersion tester, water bath
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - supplying , installation, testing and commissioning of vertical turbine pump set with ss impeller capable to discharge 126 m3/hr.against total head of 50 m, (make kirloskar/jyoti/wilo-mather&platt/wpil) coupled with suitable capacity vertical hollow shaft/solid shaft squirrel cage induction motor , rating of motor 20% more bhp than that of pump (make kirloskar /abb /cgl/ siemens) operated on 415 +/- 10% volt, 3 phase , 50 c/s a.c supply , ie3 type as per is:325 and iec:63400-ihaving speed 1450 rpm,with heavy duty m.s. column assembly with ss line shaft and each coloumn of 5 feet length including cost of supplying , fitting and fixing of all required accessories such as cidf sluice valve-1 set, cidf nr valve-1 set, pressure gauge-1 no, strainer-1 no, m.s. channel base plate etc. all complete including cost of taken out existing old pumpset., supplying and installation of fasd starter suitable for above mentioned vt pumpset make lk/bch/schneider., supplying and laying of 25 mm2 , 1.1 kv, 3 core pvc insulated unarmoured copper cable make polycab/kei/gloster, from starter to motor., supplying, installation testing and commissioning of horizontal split casing centrifugal pump set with bronze impeller having discharge 126 m3/hr. against total head of 35 m, (make - kirloskar/jyoti/wilo-mather&platt/wpil), coupled with suitable capacity squirrel cage induction motor, rating of motor 20% more bhp than that of pump(make kirloskar /abb /cgl/ siemens) ,tefc, ie3 type as per is:325 and iec:63400-ihaving speed 1450 rpm,operated on 415 +/- 10% volt, 3 phase , 50 c/s a.c supply, mounted on a commonm.s. base plate including cost of supplying , fitting and fixing of all required accessories such as cidf sluice valve-1 set, cidf nr valve-1 set, pressure gauge-1 no, foot valve-1no, etc. all complete including cost of taken out existing old pumpset., supplying and installation of fasd starter suitable for above mentioned c/f pumpset make lk/bch/schneider., supplying and laying of 16 mm2 , 1.1 kv, 3 core pvc insulated unarmoured copper cable make polycab/kei/gloster, from starter to motor., cost towards complete repairing of control panel at intake well with changing of damaged parts such as :-1.150 amp tpn mccb,50 ka -1 no. as incoming feeder.2. 75 amp tp mccb, 50 ka-2no as outgoing feeder.3.star delta timer-2nos(one for each starter) 4. 32 amp switch fuse unit -01 no. for internal and external light load.5. (0-500 v) volt meter-01 no., ampere meter-01 no.,three phase indicator lamp,powder coating paint,push button on/off,on/off/trip indicator lamp,wiring,etc as per required and testing on full load ., cost towards providing all labour, tools and technicians for taken out and dismantling 40 hp vt p/set with bowl assembly, 6" dia. coloumn pipe and line shaft etc all complete., cost towards dismantling and repairing of complete bowl assembly., cost towards making supplying and fitting s.s. top shaft as per size and sample., cost towards making supplying and fitting of c.i. spider bearing having od 6.5" with rubber bush as per size and sample., cost towards lowering of vt p/set. after complete repairing and assembling works., cost towards complete repairing of control panel at clear water pump house with changing of damaged parts such as :-1.125 amp tpn mccb,50 ka -1 no. as incoming feeder.2. 63 amp tp mccb, 50 ka-2no as outgoing feeder.3.star delta timer-2nos(one for each starter) 4. 32 amp switch fuse unit -01 no. for internal and external light load.5. (0-500 v) volt meter-01 no., ampere meter-01 no.,three phase indicator lamp,powder coating paint,push button on/off,on/off/trip indicator lamp,wiring,etc as per required and testing on full load .