Get complete information related to latest Fire Alarm System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fire Alarm System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fire Alarm System Tenders.
Tender For annual running operation and maintenance of automatic fire alarm system and fire fighting system sprinkler hydrant high expansion foam system installed at bsf hangar igi airport under airwing fhq bsf new delhi
Tender For supply & installation of compactor storage systems. 2-bay mechanical mobile compactors (12 bodies)(i) mobile compactor single face fixed unit, size: 2080 h x 1830 w x 381 d mm having 05 loading compartments = 01 nos. (ii) mobile compactor single face movable unit, size: 2080 h x 1830 w x 381 d mm having 05 loading compartments = 01 nos.(iii) mobile compactor double face movable unit, size: 2080 h x 1830 w x 762 d mm having 05 loading compartments = 02 nos.
Tender For renovation of electrical wiring and illumination system with fitting, fixing of energy saving led lighting fixture, fan and repairing of two nos voltage stabilizer at different pump houses under faws-1 scheme.
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f
Tender For maintenance of various electrical and mechanical services at thyagraj sports complex, new delhi. (sh- replacement of faulty/damaged/wornout network booster system in thyagraj sports complex).
Tender For repair maintenance of specialized electrical and mechanical services at tis hazari court delhi.(sh annual comprehensive maintenance cooper make addressable fire alarm system)
Tender For comprehensive preventive and breakdown maintenance cum round the clock monitoring of fire detection and alarm systems at different building within the campus of calcutta pavlov hospital, kolkata, for one year
Tender For stage contract for maintenance of electrical works special repair and renovation of electrical system of peripheral divisions falling under the jurisdiction of pwd (randb) circle north jammu (except raj bhawan and acb hqtr) during the year 2025-26 up
Tender For corrigendum : maintenance of office complex of advocate general at janipur jammu by way of conference hall with maximum seating capacity with the facilities of vc system in three sides and attached with washroom and pantry