Get complete information related to latest Laminar Flow Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Laminar Flow Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Laminar Flow Tenders.
Tender For corrigendum : supply of laminar flow , fan-blower , hepa filter , peripherals- associated system , installation materials and accessories , on board spares for 2 year , documentation , special tools and test equipment , system cables-cable assemblies- connector , service engineer , training
Tender For corrigendum : e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not
Tender For tender for supply of traffic light , flexible highly density polyethene tubing for water supply , installation of bro formation sign , installation of selfie point north portal , supply and fixing flex sheet , polish model room , ec7 painting , polish complete south portal , polish complete north portal guest room , door window putty & paint north portal , paint & putty to wall north portal guest room , curtain model room , fire box painting (red) , t flag , flower pot , pot stand , red carpet 3 point 3 in to 36 mtr , visitor book , supply and fixing of steel plate 5 into 12 inch , supply and fixing of steel plate 5 into 24 inch , supply and fixing of steel plate 36 into 24 inch , supply and fixing of steel plate 48 into 30 inch , supply and fixing of flex board 24 into 36 , supply and fixing of steel plate 60 into 12 inch , supply and fixing of steel plate 96 into 48 inch , supply and fixing of steel plate 60 into 36 inch , bro formation 48 into 48 , project yojak insignia 48 into 48 inch installation , stair rod , epoxy , hammer drill , fasteners , large format commercial display unit , cooling cabinet with freezer compartment , lt power insulated copper conductor cable , workstation unit , repair of toilet at museum model room bathroom , repair of museum gate , repair of led light of 3d models and roof ceiling , repair of shade of petrol pump , repair of barrier of store yard
Tender For supply of laminar air flow - 4000658, 1.000, laf specifications:-1) horizontal laminar air flow unit - platform height should be 36 inch from ground floor2) laf working station size length 40 x hight 24 x width 24 inch single undevided working space.3) lau should have closing sheet of transparent acrylic sheet.4) 2x stage filtration5) pre-filter - 10 with efficiency of 90 percent (washable hdpe media with ss 304 frame)6) supply filter - mini pleat hepa filter efficiency 99.999 percent at 0.3m (h-14)eu-14 high efficiency particulate air (aaf india ltd.), as per iest rp cc002.47) material - stainless steel 304 grade 1.2 mm8) maximum work area - maximum coverage for easier hand movements inside the cabinet. the unit has a 10 slope for operators comfort.9) motor blower assembly10)noise level - less than 60db at 1 meter from the face of the filter11)cleanliness - iso standard 14644-1 class 512)pressure gauge - digital sensor display13)air velocity - 90 fpm at 6" from face of the filter +/- 20 feet per minute14)air velocity 0.36 to 0.54 m/s and 70 to 100ft/min.15)feather touch16)provided with valid calibration certificate for laf.17)microprocessor controller for: digital pressure gauge rated filter life indicator timer for uv light uv light hour meter interlock uv and light switch18)1 year warranty for all electrical/electronic/mechanical parts i.e. whole unit.19)should be provided with two three pin plug for electricity supply both side of lfu inside for instrument attachment.20)adequate diffuse lighting, provided by fluorescent or led lights is necessary for the working area.21) eligibility of supplier - min 5 supply records in a financial year with satisfactory reports.
Tender For tender for supply of thermocouple , 621-184 type n , for furnace part no621-184 , pad foam oven bottom (part no 621-068) , mount resilient square (part no 781-677) , element , 621-183 thermocouple type n element part no621-183 , prox coal , 502-680 material lcrm tm , capacit + 50 g low part no502-680 , coal prox plus , 502-682 material standard lcrm , capacity 50 g high part no502-682 , wedge drive spindle part no 609-989 for tga 701 make leco corporation , assy harness cabinet dc part no 621-028 for tga 701 make leco corporation , assy card sm lf ecl iso therm ctrlr part no 666-602f for tga 701 make leco corporation , assy card sm lf ecl pneu flow ii part no 666-575e for tga 701 make leco corporation , assy switch button push tga 701 part no 621-104 make leco corporation , filter air 4.32x4.53x0.47 al part no 621-098 for tga 701 , assy indexer/ lift 2pos carousel part no 621-366 for tga 701 make leco corporation , crucible large glazed 621-331 for tga 701 5/pk , crucible cover , 529-048 for proximate analyzer part no529-048 , prox met coke , 502-683 material standard lcrm , capacity +50 g part no 502-683
Tender For supply, installation of equipments and other items to the pediatrics department of mims mandya - mims-pediatrics-neonatal ventilator with humidifier, mims-pediatrics-hfnc, mims-pediatrics-pulseoxymeter, mims-pediatrics-neonatal electronics weighing machine, mims-pediatrics-nebulizer heavy duty, mims-pediatrics-laminar flow, mims-pediatrics-servo control therapeutic hypothermia, mims-pediatrics-radiant warmer, mims-pediatrics-led phototherapy, mims-pediatrics-computerized pft, mims-pediatrics-portable autoclave machine, mims-pediatrics-oxygen flow meter with jar, mims-pediatrics-portable electrical suction apparatus , mims-pediatrics-ups 60 kva , mims-pediatrics-furnitures
Tender For corrigendum : supply of atg-4-air nozzle, laminar air flow cabinets or stations, air pump,air decontamination system (fumigation cum airpurification system), air condenser, air sampler, airreceivers, air freshener solid and gel, air curtain, towelhand cotton turkish (iaf)