Get complete information related to latest Office Furniture Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Office Furniture Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Office Furniture Tenders.
Tender For corrigendum : reconstruction/repair of civil structures and laying of damaged rising main and distribution at various locations under sassci work wise details given annexure i - restoration works of jal shakti (phe) city division no.i including reconstruction / repair of civil structure and laying of damaged rising main and distribution at various locations uinder sasci (phe sector). name of works:a.restoration of rising main and washed away supports of 8" rising main in lower roop nagar. b.damage of compound wall at tibba section of sub- division dhounthly. c.constuction of main gate / barbed wire fencing / road/ wall damaged near gsr 22.50 lacs glns at lohar station. d. restoration of boundary wall, roof and floor of the pump room building at phase iind muthi pumping station. e. improvement / restoration of damage chain link fencing around intake structure at cps nai muthi. f. construction of protection work to protect tube well and pump room at muthi left and muthi 6 and muthi 7 tube well at cps nai basti. g. providing and laying damage rising main at tube well muthi left, tube well no.6 and tube well no.7 nai basti at cps nai basti. h. repairement of the tube well buildings at muthi left, muthi 6, muthi 7 and cps naibasti. i. raising of udheywala station and construction of manifold and allied works of welding at tube well no.5 udheywala and suryavanshi nagar station of sub-division muthi. j. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 1st. k. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 2nd. l. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 3rd. m. construction of 200000 glns sump tank at cps samadian. n. shifting of pipe utiliies at brick klin tube well and its allied works. o. reconstruction / repairment of bath room at sub-division dhounthly and muthi. p. restore the front area by way of laying paver blocks at cps gujjar nagar. q. erection of truss over the damage roof top central pumping station cps muthi goan. r. erection of truss over the damage roof top central pumping station and dismentaling of staff qtr at station cps gujjar nagar. s. reconstruction of damage operator qtr at cps gujjar nagar under dhounthly sub-division.
Tender For auction sale of iron cable drum,ct off sizes,acsr conductor off sizes (uninsulated),joint box all sizes,pvc aluminium cable,brass,aluminium,paper stationery,ocb off sizes,xlpe cable all sizes,acsr conductor off sizes (insulated),pt off sizes,plastic meter box,pvc flexible wire all sizes,ct & pt combined unit,electric motor of all sizes,ceiling/wall fan,copper cable scrap,metering cubical,shunt capacitor - off sizes,scrap plastic meter seal,scrap lighting arrestor,empty oil drums,scrap transformer oil(hazardous),battery all sizes (hazardous),iron -acb body (refer annexure-2),acb incomplete (refers annexure-3),ring main unit 1 way (refer annexure -4),ring main unit 3 way (refer annexure -4),ring main unit 4 way (refer annexure -4),iron - ring main unit ( refer annexure- 5),transformer,11/0.433kv 400kva oil type, etc (annexure -6)
Tender For corrigendum : repairs to floor plastering work sanitary and plumbing cupboard work at stn gym noi swimming pool religious institue shivaji auditorium nofra area under age b/r-i at naval station karanja
Tender For corrigendum : procurement of furniture for newly raised echs polyclinic gagret (village brahmpur) under ge (east) jalandhar cantt - bed stead iron hospital., table bed side steel (type-ii), stool steel (type-ii), stool steel revolving ( type-i), step two tier steel., chair invalid wheeling (non folding) type-i, table 900 mm x600 mmx900mm stainless steel on castors., screen movable 3 fold steel, chair cb elevated and rotating, patient trolly stretcher., receptacle large 75 litre, receptacle small 35 litre, examination couch, iv fluid stand, cylinder trolly, board notice, lateral filing cabinet 3 drawer, rack adjustable closed on three sides 6 tier, rack adjustable open 6 tier., side rack with three trays wooden, 3 sides closed, chair cba (without arms) stackable visitor, chair cba (visitor) with padded arms, chair executive revolving low back with push back with castors, type-ii., computer chairs with arm on castors., computer chairs without arm on castors, chair folding multi seater set of 3
Tender For ca no cweafj-15/2026-27 repair/maintenance of 33kv power house eqpt, calibration, transformer oil, 33kv ug cable and allied works at af station jammu under ge (af) jammu
Tender For corrigendum : maintenance of day to day complaints of water supply including connected items at various loc under ge nagrota - m&l for repair/rectification of leakage to water supply distribution lines 15 mm dia to 25 mm dia gi tubing by necessary excavation, returning/filling as required, tightening of loose joints of union, elbow, socket etc, threading if required including replacement of gi union/socket/nipple as required complete all as specified and directed., all as per srl item no.1 above but for gi tubing of 40 mm dia to 50 mm dia complete all as specified and directed., all as per srl item no.1 above but for gi tubing of 80 mm to 150 mm dia complete all as specified and directed., all as per srl item no.1 above but for gi tubing /di /ci /ms of 150 mm dia to 300 mm dia complete all as specified and directed. note : (i) the complaints for the above works shall be registered by contractor at the water supply complaint cell of age e/m (ii) stationary required such as complaint book, job cards etc shall be arranged by the contractor and proper record shall be maintained by the contractor.(iii) tools ,plumber with helper and transport with driver for attending of above complaints shall be arranged by contractor. (iv) the rate quoted by the contractor for above jobs under item no 1 to 4 shall be inclusive of cost of works under note (i) to (iii) above. (v) the said complaints shall be rectified within 12 hrs of the registration of the complaints failing which recovery of rs.500/commplaint shall be made for contractors due payment (vi) the stores/item required for the works under item no 1to 4 shall be measured separately under relevant item as supply only. (vii) excavation, returning/ filling shall be measured and paid for separately and material required for the works above shall be included to quoted rates., excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep including getting out in hard/dense soil complete all as specified and directed., returning /filling including watering , leveling , spreading and well ramming in layers not exceeding 25cm thick complete all as specified and directed., removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 50 metre above the starting point complete all as specified and directed., refixing/relaying of old retrieved steel tubing in new or old position with and including new gi fittings (connections) and as per site requiremen laid in trenches, above ground level or in any position of following sizes as under complete all as specified and directed : -, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, taking down unserviceable gi tubing / upvc tubing from any position complete with all fittings & connections from any position of following sizes as under complete all as specified and directed :-, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply and fixing/laying & testing of galvanised steel water tubing, medium grade, isi marked complete with all new galvanized fittings of following sizes laid in trenches/ above ground level or in any position complete all as specified and directed :, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply and laying upvc pipe tubings medium grade pressure rating 10 kgf/cm2 isi mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trenches or in any other position of following sizes as under complete all as specified and directed , 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply only gi fittings, medium grade, isi marked of following sizes as under complete all as specified and directed :-, union 15 mm dia, union 20mm dia, union 25mm dia, union 32mm dia, union 40mm dia, union 50mm dia, socket 15 mm dia, socket 20 mm dia, socket 25 mm dia, socket 40 mm dia, socket 50 mm dia, reducer socket 40mmx50mm, reducer socket 15mmx20mm, reducer socket 20mmx25mm, elbow 15mm dia, elbow 20mm di
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For corrigendum : roof repair, plaster repair, painting, sanitary fittings, septic tank renovation, and other civil works at the office of assistant engineer (revenue) of 33/11 kv sub-station sasni gate, aligarh.
Tender For corrigendum : roof treatment, painting and other repair works at 33/11 kv sub-station jamalpur, aligarh and repair, related civil works of control room building at 33/11 kv sub-station beswan, district aligarh.