Get complete information related to latest Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Tenders.
Tender For tender for replacement of existing damged/rusted/rotten ht/lt pole various sites of existing feeder no4 and 11kv samoor feeder under esd hpsebl noii una bid no- ued/75/2025-26.
Tender For supply of 11kv ab cable with accessories and constructing 2.45km of ht overhead line with abc of size 3x120 sqmm plus 1x 95 sq mm insulated messenger wire on existing psc pole or a pole supports on turnkey basis for drawing new 11kv feeder
Tender For supply of welding socket unit of dimension 380(l)x650(w)x300(d) duly housed in outdoor made of high quality thermoplastic polycarbonate pc gfs (shock proof,weather pr oof, rust free, fire retardant, high impact against mechanical load) and should have degre e of ingress protection ip 65 as per iec 60529 to perform under ambient temperature - 35 deg c upto +80 degc. type of mounting: tubular pole mounting, mounting sheet material/canopy should be made of hot dip galvanized iron flat sheet material with thickness shall not be l ess than 2mm and ms flat frame (32x6)mm to be welded on gi sheet. the welding socket unit should comprisisng of the following items. 1.) copper bus bar (r,y,b,n) of each bus bar dime nsion (30x10)mm rating range 100-200amps, and separate earth strip confirmed to is 1897:200 8 or lastest.2.) 63amps 4pole residual current circuit breaker with operating volt age of 41 5volts, 50hz, tripping range : 30ma 3.) 63amps 4pole (3p+n) miniature circuit breaker with ope rating voltage of 415volts, 50hz, breaking capacity range : 10/16/25 ka 4.) 20amps 2pole (p+n) miniature circuit breaker with operating voltage of 230volts, 50hz, breaking capacity range : 10/16/25 ka (all rccb and mcb confirming to is/iec 60898-1:2002 or latest with isi mark), pref ferable make: legrand, havells, schneider, hager, l&t.5.) 63amps 5pin (3p+n+e) and 20amps 3p in (p+n+e) industrial welding socket (with spring supporting door) and suitable plug worki ng on 415volt ac supply, 50hz, of degree of protection ip 67 are designed as per iec 60309-1 and 60309-2, preferable make: schneider, hensel-walther, cape. 6.) 4runs of 16sqmm cu. frls wire. (each r,y,b,n) from copper bus bar to rccb (incomer), 4runs of 16sqmm cu. frls wire fr om rccb (outgoing) to 63amps mcb (incomer), 2runs of 6sqmm cu. frls wire from rccb (outgo ing) to 20amps mcb (incomer), 5runs of 16sqmm cu. frls wire from 63amps mcb(4runs) & green wire from earth strip(1run) to 5pin industrial socket and 3runs of 6sqmm cu. frls wir e from 20amps mcb(2runs) & green wire from earth strip(1run) to 3pin industrial socket. co pper wire confirmed of is 694:2010 or latest. preferable make : anchor, orbit, havells, polyc ab 7.) including cable gland (size confirming by consignee) for loop-in and loop-out of 4cx1 20sqmm ltug cable entry/exit from bottom conform as per en 60423 or latest. din rail for s uitable installations of all rccb and mcb upto 63amps.the manufacture should submit all t est certificate in accordance with latest iec standards. make / brand : cape consisting of 1) emp ty enclosure and mounting flange - spelsberg 2) plug and sockets 63 a/16a ? cape 3) rccb & mcb - l&t 4) conical support - powermat 5) end clamp - connect well 6) earth cable gland with locknut - trinity 7) rep uted make for miscellaneous items like copper bus bar, double compression cable gland, distribution win dow, earth busbar, ms hot dipped canopy, din rail, wiring, screws, nuts, bolts and lugs & other accessori es. hsn code 8537 1000. [ warranty period: 30 months after the date of delivery ]
Tender For tamper check paste. body material: aluminum tube type of nozzle: stainless steel. permanent ink: yes. volume: 30 ml. nature of paste: highly visible, viscous and fluorescent colour: orange. tip size: 2.9mm. extra nozzle of 1 mm and 2 mm should be provided. make: century /luxor/ eatech /posterman /sakuraor. one sample to be approv ed by consignee before effecting the bulk supply. [ warranty period: 18 months after the date of delivery ]
Tender For providing new street lighting, high mast lighting system with led fittings, copper wiring cover shed, d e and shifting of existing ht lt poles, repair of transformer, rooftop solar power plant in ngm budhlada, m.c. budhlada, district mansa. .
Tender For 85932 repair/maintenance of transformer, ht ug cables, god, ht distribution system, poles, protective devices, earthing and other miscellaneous work of electric supply in area no. i and ii and other area of age em-i under ge (south) pune
Tender For corrigendum : repair/maint of lt oh lines/ug cables, lt feeder pillar boxes, lt panels, poles, capacitor, panels, connected switch gears and other allied works at unchibassi under ge south pathankot
Tender For repair/maintenance of lt overhead lines, lt cables, lt switchgears and feeder pillar, street lights/solar street lights/pole /cable/junction boxes/timer switches including connected works in various locations at ajmer mil stn under ge nasirabad