Get complete information related to latest Radiology X Ray Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radiology X Ray Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radiology X Ray Tenders.
Tender For providing of customized amc/cmc for pre-owned products - comprehensive annual maintenance contract (including spare parts and all charges) x-ray baggage inspection system (rap 618 xr) on pac basis; ecil rapiscan ltd; comprehensive maintenance contract (cmc); quar..
Tender For providing of customized amc/cmc for pre-owned products - comprehensive annual maintenance contract of x-ray baggage inspection scanner/system (xbis)& under vehicle scanning system uvss) at lpg bottling plant gopanari for 05 years
Tender For corrigendum : supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8
Tender For supply of all types of consumable items like: gauge, bandage, disposable syringe, cannula, infusion/transfusion sets,reagents or others products used in pathology lab, radiology etc. [ warranty period: 30 months after the date of delivery ]