Get complete information related to latest Ship Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ship Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ship Tenders.
Tender For corrigendum : providing of hiring of custom house agent - lumpsum based - export; custom clearance, assistance in post shipment export benefits claims (duty drawback or any other applicable claims); petrochemical(s)
Tender For corrigendum : providing of hiring of boats - tugboat; less than 10 years; with air-conditioning; as per class; na; inboard; steel; rescue life jackets, lifebuoys, fire extinguisher, first aid box; buyer
Tender For corrigendum : providing of hiring of boats - tugboat; less than 10 years; with air-conditioning; as per class; na; inboard; steel; lifebuoys, rescue life jackets, fire extinguisher, first aid box; buyer
Tender For corrigendum : supply of supply of floor mounted direct radiography system with dual detector under buy-bcak policy floor mounted direct radiography system with dual detector floor mounted direct radiography system with dual detector:- 1.generator the generator should be high frequency capacity of 30 kw or more. kv range should be 40 kv- 125 kv or more. the output at 80 kv should be 400 ma or more. generator frequency should be 200khz or more 2. x-ray tube and collimator the x-ray tube should be of rotating anode with dual focus having the following sizes: (i) large focus: 1.5 mm or less. (ii) small focus: 0.6 mm or less the unit should have anode heat storage capacity of 100 khu or more. distance measuring scale should be provided. should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. the light output should be minimum 160lux tube rotation on vertical axis should be - 180 degree locked (clockwise) & + 120 degree (anticlockwise) at least with end stopper. the tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. touch screen display on tube head to control kvp & mas as well as selection of body parts. 3. vertical detector stand the unit should be provided with vertical stand. the unit should have provision to do all upright x-rays. the vertical detector should travel from at least 1.4 ft to 5.5 ft above floor level. it should be flat vertical motion can be locked in any position. 4. table the table top should be floating with transverse and longitudinal movements 250 mm, 300 mm respectively or better. the table should have a weight bearing capacity of minimum 200 kg or more. the table should have anti scatter grid electromagnetic ) /bid number : gem/2026/b/7398823 * /dated: 28-03-2026 & & / bid document 1 / 8
Tender For corrigendum : supply of ars items - garbage bag , dust bin , detergent powder , deodriser refill for ship head 8 cm x 3 cm , soap liquid toilet , room freshner , pest seal , hand washliquid , glass cleaner 500 ml , disinfectant fluid white black , cleaning liquid for utensils , hand towel , paint white enamel , paint silver , paint rfu priming red lead , paint red oxide , paint olive green primer , paint epoxy allum primer , paint coal tar epoxy black , paint black heat resisitance , paint epoxy red cxider primer , paint brush 4 , paint brush 2 , mosquito reolellent gel , fiber dust brush , sprey hand liquid insecticide , mosquito repellent machine with liquid
Tender For bid to ras supply of distilled water , napthalene balls , mug plastic , garbage bag , dust bin , detergent powder , deodriser refill for ship head 8cm x 3cm , soap liquid toilet , room freshner room spray
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - ship; defect rectification on ac compressor no 02 (l-135); service provider
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - icgs rajshree; l 181 ships tvro system make intellian is not acquiring tv signal reception at harbor sea suspect antenna and sub reflector units are misaligned and acu a..