Get complete information related to latest Sports Ground Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Sports Ground Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Sports Ground Tenders.
Tender For providing and fixing pvc wall panelling in gymnasium and administrative block, repairs to false ceiling in gymnasium and squash courts, providing and fixing g.i. profile sheet in parking area, polishing of flooring in squash courts and other
Tender For repairing of power line and installation of panel, voltage correction arrangement with allied works at p.h. no.i, zone- iii of bongaon municipality ground water based w/s scheme under emsd-i, phe dte.in 24pgs(n).
Tender For repairs to under ground drainage pipe lines at peerzadiguda dharga sai nagar colony rayanacha colony road no.3 sree ram nagar colony of ward no 9 medipally ward 10 peerzadiguda of boduppal circle-10, uppal zone, mmc
Tender For repair and renovation of the room at south east corner near by the sales counter (at right position of partition wall) ground floor of asutosh building building college street campus, university of calcutta.
Tender For repair/replacement galvalume sheets, ceiling and certain joinery related items in permanet and temporary bldgs of n-4, narendra ground and rama devi at afs chakeri , kanpur - taking down chowkats or frames not exceeding 1.5 sqm each but with shutters (without taking off shutters from the frame), and removing from site complete all as specified and directed., ditto all as per item no.01 above but exceeding 1.5 sqm but not exceeding 4sqm each., dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed., framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to fe.290.gde-e-165, s&f solid pvc door frame of size 50mmx 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube all as per specification and drawing., s&f factory made solid panel factory made solid pvc moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded pvc sheet on the front face & 2mm plain colour pvc sheet on back face, supplying & fixing in frame at site as per specification & drawing, s&f pvc butt hinges medium weight, 100 mm long, complete all as specified and directed., s&f 150 mm size aluminum, anodised, barrel tower bolts of extruded section., s & f 125 mm long aluminum anodised bow handle fabricated type extruded section complete all as specified and directed., s&f 300mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete., factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 45 x 85 mm comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum comp ressive strength of 58 n/mm2, modules of elasticity 900 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/ moisture proof and fire retardant note: for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made., factory made single extruded wpc (wood polymer composite) solid door/ window/ ceosetory windows & other frames/ chowkhat of size 50 x 125 mm for double shutter door comprising of virgin pvc polymer of k value 58-60 (suspension grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 n (face) & 1100 n (edge), minimum comp ressive strength of 58 n/mm2, modules of elasticity 900 n/mm2 and resistance to spread of flame of class a category with property of being termite/borer proof, water/ moisture proof and fire retardant note: for wpc solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made., factory made single extruded wpc (wood polymer composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of k value 58-60 (s
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For repairs to compound wall, fencing and gate with connected items in domestic area and omq area at afs under ge (af) jorhat - demolition of brick work built in cement mortar of any description complete all as specified and as directed., m&l for brickwork (old size) with sub class b bricks, straight or curved on plan exc. 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed., all as per serial item no. 2 here-in-before but except bricks, using old serviceable brick as retrieved from demolition.note : old serviceable bricks obtained from serial item no. 1 above shall re-used., taking down cement plaster on brick or stone or concrete surfaces of walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed., m&l for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cm (1:4), finishing the surface even and smooth without using extra cement complete all as specified and as directed., m&l for preparation of new plastered surfaces of walls and applying two coats of cement base paint over and including one coat of alkali resistance primer complete all as specified and as directed., demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed., m&l for plain cement concrete (1:2:4) type b-0 (using 12.50mm graded stone aggregate) used as in benching and coping including necessary formwork complete all as specified and as directed., m&l for brickwork with sub class b bricks, straight or curved on plan to any radius in half brick thick walls, built in cm (1:4) complete all as specified and as directed., m&l for dismantling posts or struts (wood, steel or rcc) any section, including taking out embedded portion and making good to disturbed ground surfaces complete all as specified and as directed., m&l for plain cement concrete (1:3:6) type c-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete, etc. complete all as specified and directed., s&f hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing, etc. wind ties for roof including securing bolts posts and struts in fencing of size 65x65x6mm including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to fe-290 gde e-165 complete all as specified and as directed., dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed., s&f 11mm to 15mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and onehexagonal or square nut, but length of bolt exc. 5cm but n. exc. 10cm complete all as specified and as directed., excavating in post holes (or similar holes) each n. exc. 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exc. 50m and making good surface as in soft/loose soil complete all as specified and as directed., m&l for preparation of new steel and iron surfaces of any description over 10cm width or girth not otherwise described for and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed., m&l for mild steel tmt bar 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends binding wit
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con