Get complete information related to latest Tank Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tank Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tank Tenders.
Tender For vacuum of transformer tank with dehydration filtration of transformer oil and air dryer generator unit for erection installation work of 220/132 kv, 160 mva power transformer at 220 kv gss rvpn sikri
Tender For corrigendum : tn-18368 supply of various electrical items at kstps, kota - supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota., supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota., supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area., supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifier-iii for u# 6 & 7 of kstps, kota., supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota. kst, supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-ll, kstps, kota., supply of various electrical items at kstps, kota., supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installed at kstps, kota., supply of valves at kstps, kota., supply of misc. rubber items at kstps, kota., repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota, online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota, day to day joinery works inside & outside plant site, kstps, kota, capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps, kota., annual rate contract for 6.6kv vpi and non vpi ht motor rewinding from 175 kw to 4000 kw with new coils of insulation class 'f' and other additional works of stator and rotor.
Tender For corrigendum : supply of various electrical items at kstps, kota- supply of 3 phase, 415v lt motors for unit #1 to 7 at kstps, kota. , supply and retrofitting of oltc of unit auxiliary transformer-4b at kstps, kota. , supply of conveyor carrying idler frame & carrying idler frame troughing trainer for conveyor system in chp area. , supply, installation, testing & commissioning of vaccum type gaseous chlorinator system capacity up to 20kg/hr with all accessories for pre treatment plant clarifer-iii for u# 6 & 7 of kstps, kota , supply of submersible dewatering/ mud pumps for cw, bcw & dmcw area of kstps, kota , supply of middle collectors (laterals/intrabed distributors) for strong acid cation vessels of dm plant, stage-li, kstps, kota , supply of various electrical items at kstps, kota , supply of portable and trolley mounted fire-extinguisher of different capacities for first-aid fire fighting system (extinguisher) installied at kstps, kota , supply of valves at kstps, kota. , supply of misc. rubber items at kstps, kota. , repair/machining of components of turbine & auxiliaries of unit 1 to 7 of kstps, kota , online helium leak detection test of condenser vacuum zone of unit # 1 to 7 (stage i to v) of kstps, kota , day to day joinery works inside & outside plant site, kstps, kota , capital, routine & breakdown maintenance of c&i instruments and equipments of stage-i to v, analyser, dm plant, clarifier, ics and cctv systems at kstps,kota , annual rate contract for 6.6kvvpi and non vpiht motor rewinding from 175kw to 4000 kw with new coils of insulation class fand other additional works of stator and rotor
Tender For supply of sitc manual hydrotesting unit 10 head 14.2 and 19kg with accessories complete , sitc vacuum cleaning machine with nozzle and other related accessories , sitc l1 l9 gauge c1 c2 gauge set , supply low voltage lamp and magnetic torch , sitc high pressure air compressor for pneumatic testing with air vessel , sitc chain conveyor system 14.2 or 19 kg , sitc 5hp helical drive unit 12 to 14 mpm speed , sitc roller conveyor 14.2 or 19 kg
Tender For supply of sitc manual hydrotesting unit 10 head 14.2 and 19kg with accessories complete , sitc vacuum cleaning machine with nozzle and other related accessories , sitc l1 l9 gauge c1 c2 gauge set , supply low voltage lamp and magnetic torch , sitc high pressure air compressor for pneumatic testing with air vessel , sitc chain conveyor system 14.2 or 19 kg , sitc 5hp helical drive unit 12 to 14 mpm speed , sitc roller conveyor 14.2 or 19 kg
Tender For corrigendum : supply of oh of main steam line valve v2 6 , oh of steam by pass valve v2 27,15, and v2 7 , oh of es 3,4,5,6 and 7 , oh of v2 -82-84 and v2-81-a to 81c , oh of hd-21, hd-29, hd-30 and hd-31 , oh of nrv of h.p. heater and feed pump , oh of group protection valve of hph , oh of dw-4, 37,38,39,40,41 and ca 5 , oh of cst makeup valve v6 60 , oh of as-48 valve , oh of nrv of extraction line es-8 , oh of suction valve of bfp , oh condensate wtr throw off valve to condenser , oh throw off valve to cond and steam isolating of lph2 , oh of steam isolating valve of lph 3, 4 , oh of safety valve of aux prds or deaerator , oh of safety valve of h.p. heater , oh of safety valve of l.p. heater. , oh of safety valve of cbd tank. , oh of safety valve of flange or stud heatng , oh of safety valve of warm up line. , overhauling of actutator of as 48 valve , oh of actr feed line valvev2 81 or v2 82 or v2 83 or v2 84 , oh of actr of v2 7 or v2 15 or v2 27 , oh of actr drip line valve and ext line valve , oh of actr valve connected to condenser , oh of actr cst make valve , oh of actr of msv l and r , oh of actr of steam isolating valve to lph2 to 4 , oh of actr steam throw off valve to condenser , cut or weld or repl of hp valve 15 to 50mm , cut or weld or repl of hp valve 51 to 100mm , cut or weld or repl of h p valve 101 to 150mm , oh of butterfly valve of condenser , oh of dea and fst with internal painting , repair or replacement of broken hanger , tightening of loose hangers , cut or weld or repl of l.p. valve 15 to 50mm , cut or weld or repl of l.p. valve 51 to 100mm , cut or weld or joint of h.p. pipe 15 to 50mm , cut or weld or joint of h.p. pipe 51 to 100mm , cut or weld or joint of h.p. pipe 101 to 150mm , cut or weld or joint of h.p. pipe 151 to 300mm , lift or straight aprds hdr by cutting weldding , o h of lph 1a , 1b , o h of lph 2 3 and 4 , oh and attend flange leakage of gc i or ii , clean of turbine oil or h2 gas cooler str , repl of damaged sp. valve v2 38 , repl of damaged special valve v2 27 , oh of turbine oil coolers , oh of main ejectors of turbine , oh of h.p. heater , oh of lcv 3to15pcv-5, 14,16,17,tcv 8 , repl bend of lp drip connected to drip pump or condenser , cut damaged bend of hph drip cont to dea , cut weld or repl of h.p. valve 151 to 300mm , blank of crh line for ht and normalizing , oh of h.p. valve nrv in h.p. line , oh of l.p. valve nrv , oh of energy absorber of bfp , oh of dss of aux. prds.
Tender For supply of set of air vent valve (01 no) and vacuum valve (01 no) for roof water tank for lhb coaches. as per drg. no. lw63150 alt ? e or latest, item no. 3 & 4 specn: as per drawing. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply and replacement of defective parts of kirloskar make transformers of 1000/750/500 kva capacity at ugc & cag building, new delhi. - supply and fixing of over current earth fourth relay 24 dc l&t make etc complete as reqd. , supply and fixing of 11 kv indoor single phase resin cast current transformer 300/5amp etc complete as reqd., , supply and fixing of transformer 500 kva 11/0.433 kv wt1 scanner & rtd sencer lead., , supply & installation of suitable rating of 500 kva 11/0.433 kv lv bussing porcelain or epoxy-cast resin comply with is-1180 complete as required, , supply and fixing of suitable rating of 500 kva 11/0.433 kv lv flexible porcelain or epoxy-cast resin comply with is-1180 complete as required., , dismantling /loading and unloading of 500kva, 11kv/433volt, 3phase, 50hz, cast resin dry type kirloskar make indoor transformer hv/lv coil/core etc and repair of crack in hv/lv winding/core and putting cast resin/resin hardener, reassembling all the dismantle parts accessories confirming to is 11171 and iec 60076 etc including all tests i.e voltage ratio, magnetic balancing, vector group, ir magnetizing current, winding resistance etc complete as reqd., , supply & installation of 630a vcb vacuum interrupter etc complete as reqd., , sh-2 (old cag bldg), , supply and replacement of 750- 1000 kva transformer oil gas kit etc complete as reqd., , checking in 750-1000 kva transformer all type of protection etc complete as reqd., , supply and replacement of lv bushing oil seal in 750-1000 transformer etc complete as reqd. no.ryb) (4, , supply and replacement of hv bushing oil seal in 750-1000 transformer etc complete as reqd. (3 no. r,y, b), , supply and replacement of off load tape changer in 750-1000 kva transformer etc complete as reqd., , replacement of transformer oil in oltc top-up of main tank etc complete as reqd., transformer oil filtration and dehydration of 750 kva & 1000 kva transformer using high-vacuum oil filtration plant, including removal of moisture, dissolved gases, sludge and impurities from transformer oil, circulation of oil through filtration machine, achieving required bdv value, testing before and after filtration, manpower, tools & tackles, consumables, complete as required at site., , complete servicing, overhauling, cleaning, contact checking, lubrication, insulation resistance testing, contact resistance testing, functional testing and commissioning of oil circuit breaker (ocb), complete as required at site., , supply & installation of male contact, , supply & installation of female contact, , supply & installation of over current earth fault relay, , supply & installation of 24 volt dc power pack unit etc complete as reqd., , supply and fixing of transformer wti relay etc complete as reqd.., , supply and replacement of transformer oti relay etc complete as reqd.., , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., , (make: schneider electric-nsx /siemens / lk/ abb/hager)