Get complete information related to latest Vacuum System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum System Tenders.
Tender For supply of supply of analyser systems for panipat refinery expansion project p25 d d - group a items process stream analyser h2s thc as per groupa of mr tag nos 414 at 1101 , transportation from vendors works to site for group a items , supply of mandatory spares for group a as per mr , site work for group a as per mr , training charges at site for group a , pwcamc - post warranty maintenance comprehensive for 05 years for group-a as per mr , supply of group b items process stream analyser h2 as per group b of mr tag nos 416 at 3401 , transportation from vendors works to site for group b items , supply of mandatory spares for group b as per mr , site work for group b as per mr , training charges at site for group b , pwcamc post warranty maintenance comprehensive for 05 years for group b as per mr , supply of group c items o2 tdls cdu and vacuum heater as per group c of mr tag nos 451 at 5001 and 451 at 5002 and 452 at 3101 , transportation from vendors works to site for group c items , supply of mandatory spares for group c as per mr , site work for group c as per mr , training charges at site for group c , pwcamc post warranty maintenance comprehensive for 05 years for group c as per mr , supply of group d items process stream analyser h2s h2 cos as per group d of mr tag nos 416 at 3601 , transportation from vendors works to site for group d items , supply of mandatory spares for group d as per mr , site work for group d as per mr , training charges at site for group d , pwcamc post warranty maintenance comprehensive for 05 years for group d as per mr , supply of group e items process stream analyser h2s nh3 as per group e of mr tag nos 414 at 1102 , transportation from vendors works to site for group e items , supply of mandatory spares for group e as per mr , site work for group e as per mr , training charges at site for group e , pwcamc post warranty maintenance comprehensive for 05 years for group e as per mr
Tender For empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For corrigendum : complete repairing, servicing and periodical maintenance of 02 nos. air dryers trident make atlas copco make installed at1200lpm old gas plant room and 02 nos. medical vacuum pumps installed at new gas plant 4400 lpm of govt. medical college h