Get complete information related to latest Absorbent Filter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Absorbent Filter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Absorbent Filter Tenders.
Tender For operation and maintenance of stp (11mld tf and 10 mld wsp), along with existing sewerage network line for one year including replacement of filter media and including laying of new di 150 mm dia etc
Tender For restoration of 500 lpm ogp at sub district hospital sunderbani - servicing of air compressor of 500 lpm ogp by way of removing old air oil separator-02 nos, air filter -02 nos, oil filter- 02 nos, and draining compressor oil 40 litres and providing and fitting of new air oil separator 02 nos, air filter 02 nos, oil filter -02 nos, and compressor oil 40 litre. the job includes cost of material and labour charges for repair at site and all taxes as applicable.(compressor make fscurtis model: sem-60-a115electrical motor: 45kw, 60hp, 400v, 50hz), repair to gas pipe line system by way of checking out of leakages of 15mm, 28mm and 42mm copper pipe by way of gas welding/brazing ,replacement of damaged valves of 28mm & 42mm. the job includes cost of material and labour charges for repair at site and all taxes as applicable., repair to electrical main panel of the plant by replacing the damaged 160 amp and 125 amps 3 pole mccb . the job includes cost of material and labour charges for repair at site and all taxes as applicable
Tender For repair/ maint of external water supply pipe line, replacement of filter media, improvement of water supply installations and maintenance of winter/ summer appliances
Tender For corrigendum : supply of control valves for lara singrauli and talcher projects - lara-cv-asv-8, dea pegging from aux. steam header , lara-cv-crhv-6, dea pegging from crh line , lara-cvcdv-25, low load condensate control , lara-cvcdv-39, gsc min. flow recirculation , lara-cv-cdv65, cep-a min. flow recirculation , lara-cv-cdv-67, cep-b min. flow recirculation , lara-cv-cdv-69, cep-c min. flow recirculation , lara-cv-cdv-43, excess dump control , lara-cv-cdv-72, condensate for valve gland sealing and flash tank , lara-cv-cdv84, condensate spray for flash tank , lara-cv-cdv94, condensate spray for unit flash tank , lara-cvdrv-53, hph-9a normal drain to hph-8a , lara-cv-drv59, hph-9b normal drain to hph-8b , lara-cv-drv-56, hph-9a alt drain to flash tank , lara-cv-drv-62, hph9b alt drain to flash tank , lara-cv-drv-2, hph-8a normal drain to hph-7a , lara-cv-drv-8, hph-8b normal drain to hph-7b , lara-cv-drv-5, hph-8a alt drain to flash tank , lara-cv-drv-11, hph-8b alt drain to flash tank , lara-cv-drv-15, hph-7a normal drain to deaerator , lara-cv-drv-22, hph-7b normal drain to deaerator , lara-cv-drv-18, hph-7a alt drain to flash tank , lara-cv-drv-25, hph-7b alt drain to flash tank , lara-cv-drv-82, lph-5 normal drain to lph-4 , lara-cv-drv-85, lph-5 alt. drain to flash tank-b , lara-cv-drv-65, lph-4 normal drain to lph-3 , lara-cv-drv-68, lph-4 alt. drain to flash tank-b , lara-cv-drv-77, drip pump discharge control , lara-cv-drv-31, lph-3 alt. drain to flash tank-b , lara-cv-drv-48, deaerator overflow to flash tank-b , lara-cv-dmv-43, normal dm mu to hotwell , lara-cv-dmv-78, emergency dm mu to hotwell , lara-cv-asv-16, drain of aux steam from existing unit header to unit flash tank , lara-cvdmcwsg12, dmcw system for sg aux , lara-cvdmcw18, dmcw system for tg aux , lara- one fourth inch ss tubing -12 meter for each tag , lara- ss fittings for connection to air filter regulator- for each tag , lara- ss fittings for connection to air lock relayfor each tag , lara- ss fittings for connection to ia header isolation valve - for each tag , lara- ss equal tee - for each tag , lara- ss half inch npt m x one fourth inch od tube connector- for each tag , lara- commissioning spares gaskets and gland packing set for each valve , lara- valve diagnostic and configuration software , lara- cv test charges , lara- mandatory spares- pneumatic and electro hydraulic actuator assembly or equivalent item applicable for selected actuator type shall be provided, 1 no. of each type model and rating , lara- mandatory spares- diaphragms, o rings, seals etc.- 5 nos. of all types make etc. , lara- mandatory spares- solenoid valves if applicable - 1 no. of each type , lara- mandatory spares- smart positioners complete unit and accessories link assembly - 2 nos. of each type, model and rating , lara- mandatory spares- pneumatic air filter or regulator- 2 nos. of each type, make rating etc. , laramandatory spares- air lock relays- 1 no. of each type, model and rating , lara- mandatory spares- valve trim - including cage, plug, stem, seat rings, guide bushings etc. - 1 set for each type,class,size of control valve , lara- mandatory spares- gland packing- 5 sets , lara- mandatory sparesgaskets- 5 sets , lara- mandatory spares- cep recirculation valve trim which includes spindle with cone, seat ring, guide bush, cage- 1 set , lara- mandatory spares- cep recirculation valve soft parts i.e. gland packing, seals, orings, gaskets etc.- 3 sets , lara- mandatory spares- ss fittings for connection to air filter regulator- for each tag- 100 nos. of each type , lara- mandatory spares- ss fittings for connection to air lock relay- for each tag100 nos. of each type , lara- mandatory spares- ss fittings for connection to ia header isolation valve- for each tag- 100 nos. of each type , lara- mandatory spares- ss equal tee- for each tag- 100 nos. of each type , lara- mandatory spares- pneumatic air filter or regulator- 20 nos. of each type and model , laramandatory spares- v
Tender For supply of low voltage card section , high voltage module type , area gamma radiation indicating meter with auto ranging type , mains transformer with line filter card type , detector assembly , 6 digit degital electromagnetic counter 12 v , photo-multiplier tube
Tender For procurement of disposable and implants items for ctvs department rgssh - part-01, oxygenator membrane (adult) with hard shell reservoir:1. should have a micro porous hollow fibre membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 220ml6. should have high efficiency heat exchanger.7. venous return port with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8 venous inlet 10. should have sampling port., oxygenator membrane (semi-adult) with hard shell reservoir:1. should have a micro porous hollow fiber membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 3000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow range 0.5 ltr to 3.5 ltr/min.5. should have priming volume less than 180ml6. should have high efficiency heat exchanger7. venous return port 3/8 with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8 venous inlet 3/8 10. should have sampling port., oxygenator membrane (paed.) with hard shell reservoir:1. should have a microporus hollow fiber membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 1000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow upto 2.8 ltr/min.5. should have priming volume less than 140ml6. should have high efficiency heat exchanger.7. venous return port 3/8 with rotating facility and redurs8. should have an auto vent facility.9. port size : arterial outlet 1/4 , venous inlet 3/8 with redurs, oxygenator membrane (neonatal):1. should have venous inlet .2. arterial outlet port tubing size.3. it should have least priming volume less than 70ml.4. arterial flow upto 1.2 ltr/minute.5. approximate reservoir capacity should not be 600ml.6. should have redurs.7. blood inlet and outlet port size redu able to 3/16 ., pre-connected tubing pack adult with arterial line filter:1. circuit diagram attached.2. tubing should have transparent, medical implant grade pvc of class vi usp, marked., pre-connected tubing pack paed. with arterial line filter:1. circuit diagram attached2. tubing should have transparent ,medical implant grade pvc of class vi usp, marked, pre-connected tubing pack paediatric small. with arterial line filter:1. circuit diagram attached2. tubing should have transparent ,medical implant grade pvc of class vi usp, marked, pre-connected tubing pack neonatal. with arterial line filter:1. circuit diagram attached.2. it should have a good quality arterial filter pore size should have 35-40 micron.3. tubing should have transparent medical implant grade pvc of class vi usp, marked., online blood cardioplegia delivery system:1. should have in built high efficiency heat exchanger of metallic for fast cooling & re- warming.2. should have priming volume less than 80ml.3. should have max flow rate 1 ltr/min4. should have pressure drop not more than 13mmhg 500ml/min5. should have blood to crystalloid ratio of 4:1 with bride connection facilities and interchangeable tubing ratio.6. should have auto-vent line system on accidental bock of cardioplegia deliver liner.7. pvc tubing should have medical implant grade of class vi ,usp, marked., ante- grade root cardioplegia cannula with side arm:1. should have size 12fr,14 fr. & 16 fr.2. should have regular tip stilate with side arm for vent with flange3. selection strictly on quality basis., ante- grade root cardioplegia cannula without side arm:1. should have size 12fr, 14 fr. & 16 fr.2. should have regular tip stilate with flange3. selection strictly on quality basis.4. iso certification, coronary ostial ca