Tender For corrigendum : erection dog to panther conversion of s/c 66kv manjal - makhana line by erecting d/c panther tower with acsrpantherconductor under r&m plan 2024-25. (work under construction division anjar)
Tender For corrigendum : provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, brea
Tender For supply of led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , led 36 watt square type 2 feet by 2 feet recess mounted light , pvc storage tank 2 layer of 1000 ltr capacity , single core 4 sqmm fr lsh pvc insulated industrial grade copper conductor unsheathed flexible cable 1100 volt conforming to is 694 , single core 2. 5 sqmm fr lsh pvc insulated industrial grade copper conductor unsheathed flexible cable 1100 volt conforming to is 694 , flexible twin twisted wire 23 of 0. 76 sqmm , sink stainless steel of 36 inch x 18 inch x 8 inch , cp towel ring square shape , gi nipple 20mm 4 inch dia long , modular switch 6 amp 1 way , bow handle aluminium 125mm , twin twisted flexible copper wire of size 23 of 0. 76 sqmm , socket gi 20 mm , grating cp 100 mm , pvc plain bend 110mm dia , aluminium door handle 200mm , led lamp 0. 5 watt round b 22 red or green , grating pvc 100 mm , led flood light 100 watt , gi elbow 100 mm , gi union 20 mm , gi union 25 mm , socket 100 mm , gi union 50mm , socket gi 25 mm , cp handle 150mm , cp handle 75mm , automatic transfer switch of capacity 125 amps 415 volts three phase and neutral double breake contact system adjustable , automatic transfer switch of capacity 200 amps 415 volts three phase and neutral double breake contact system , electronic motor protection relay 230 volts with thermal ol range 16 to 88 amps with in built protection , under voltage release 415 volts ac with time delay 0-1-3-5 sec suitable for u power omega type acb , closing release 240 volts ac suitable for u power omega type acb , shunt release 240 volts ac suitable for u power omega type acb , aluminium rectangular 18 x 12 mm conciled profile light channel with difussed cover , led strip light warm white 5 mtr long 15 watt 24 volts //bid details2 / 34
Tender For corrigendum : work of erection of balance work of 66kv s/c line on h frame from 66kv sadla s/s to 66kv umarda s/s with acsrpantherconductor under kisan suryoday yojana.
Tender For corrigendum : erection work of 66kv d/c line from 66kv dumra s/s to 66kv bayth s/s with d/c line on d/c panther tower with acsrpantherconductor under r&m plan 2024-25 (work under construction div anjar)
Tender For bid to ras supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volume control dampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning o
Tender For tender for supply of ht cable -m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the sam
Tender For work of replacement of existing 0.2 acsrpantherconductor by equivalent hpc conductor along with suitable hardware, accessories and porcelain long rod insulators for 132kv akole - kombhalne line along with replacement of ehv equipments at 132kv akole & 132kv kombhalne s/s under ehv pc o&m zone, nashik
Tender For supply of erection of 33kv line of munnalal ss d d - swg -0. 5 kg. or pole , erection, installation and commissioning of aluminium paint , erection, installation and commissioning of red oxide paint , erection, installation and commissioning of bolts, nuts and washer all sizes , erection, installation and commissioning of e-bracket , erection, installation and commissioning of f-bracket or top cleat in ms channel , erection, installation and commissioning of eye bolt , erection, installation and commissioning of aluminium lug of suitable size , erection, installation and commissioning of hdpe pipe 150 mm dia , erection, installation and commissioning of gi pipe 6inch dia , erection, installation and commissioning of m. s. angle iron 65x65x6mm, 4300 mm long 2 or 6 or 8 no. erection, installation and commissioning of bracing, with 4 or 12 or 16 clamps -5. 8 kg. or m , erection, installation and commissioning of m. s. angle iron 65x65x6, 3200mm long, 5. 8 kg or mtr. for cable with clamp , erection, installation and commissioning of top channel 125x65mm, 3200 mm long -13. 10 kg. or m with clamp , erection, installation and commissioning of guarding angle 75x75x6mm -3500 or 2200 mm long , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of st pole 11 mt long-sp-55 , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of st pole 16 mt long-sp-78 , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of v-type cross arm 100x50x6 mm , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of 33 kv disc insulator bands. type 70 kn. , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of disc fittings panther 70 kn. , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of 33kv pin insulator , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of 33kv pin with nut , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of gi wire 6 swg for guarding along the line , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of gi wire 8 swg for guarding a cross the line , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of earthing complete with gi wire 8swg , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of single core pvc cable 1x240 sq. mm. , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of complete stay gi stay rod 20x1800 mm, stay 7 or 8 swg 10 kg. , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of 33 kv xlpe cable 3x300 sq. mm. carrige only , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of 33 kv xlpe 3x300 sq. mmm c or j or kit outdoor , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of acsrpantherconductor //bid details2 / 4429 km. , safe carriage, shifting up je dump store or side from any esc center of jhansi zone and erection, commissioning and installation of 33kv rmu 3 way , concreting, grouting and muffing of support -stp or pcc pole 0. 268 cu. mtr or pole with mater