Tender For construction of 132/33 kv (2x80 mva) , grid sub-station chausa (district-madhepura) along with construction of 132 kv d/c chausa- udakishunganj transmission line with acsrpantherconductor (line length - 20 rkm) , construction of 132 kv d/c chausa- bhawanipur transmission line with acsrpantherconductor (line length - 20 rkm), construction of 02 nos. of 132 kv line bay at upcoming 132/33 kv gss bhawanipur (district- purnea) & construction of 02 nos. of 132 kv line bay at 132/33 kv gss udakishunganj (district-madhepura).
Tender For work of erection of 66 kv s/c prop. 220kv kanbha s/s to 66kv bhuvaladi s/s line on d/c panther tower with al-59 conductor with eq. weight to acsrpantherconductor under nadiad construction division under nadiad tr circle.
Tender For supply, erection, testing and commissioning of stringing of second circuit on 132kv yemmiganur-madhavaram dc/sc line with acsrpantherconductor (26.8km) and 01no. new 132kv bay extension at 132kv ss madhavaram and 01no. new 132kv bay extension at 132kv ss yemmiganur in kurnool district
Tender For corrigendum : erection work of 66kv d/c nadapa-kanaiyabe on d/c panther tower with d/c acsrpantherconductor line (work under construction div. anjar)
Tender For corrigendum : erection work of 66kv s/c line from 66kv kidiyanagar-bhimasar line on d/c panther tower with acsrpantherconductor (work under construction div anjar)
Tender For corrigendum : erection work of lilo to 66kv (proposed 220kv gadhsisa) ss on d/c panther tower with acsrpantherconductor from existing 66kv kotda(r)-khirasar line on d/c panther tower with acsrpantherconductor (under construction div. anjar)
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin
Tender For tender for supply of attending ea set located upto 25km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 25km to 50km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 50km to 100km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , attending ea set located between 100km to 200km from dist hq incl rectification of minor fault in wiring , lubricating etc nothing extra will be paid for repeated fault within 4month of the first visit , carry out b check servicing of 7.5kva to 15kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 15kva to 32.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of above 32.5kva to 62.5kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool n tackle etc as reqd , carry out b check servicing of above 62.5kva to 125kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 160 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 200 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , carry out b check servicing of 250 kva ea set of various make with replacement of engine oil fuel and lub oil filter coolant etc arranging vehicle manpower tool and tackle etc as reqd , providing and fixing of 12mm dia wire braided pvc pipe for diesel supply and return lines in existing ea set incl. testing , commissioning etc as reqd , providing and fixing of benjo and benjo bolt with washer and scew on pipe clamps at both ends for existing ea set incl. testing , commissioning etc as reqd , providing and topping up of corrosion inhibitor coolant in radiator of existing ea set incl. testing , commissioning etc. as reqd. , providing and topping up of 15w40 grade lubricating oil of recommended make in existing ea set incl. testing , commissioning etc. as reqd. , providing and fixing of 2 no. 50 sqmm copper conductor flexible cable leads each of 1 mtr length incl. lugs and battery terminals at both ends for starting battery of existing ea set as reqd. , providing and fixing of battery terminal socket set for dg starting battery incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve suitable for 7.5 kva to 32.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of stop solenoid valve with solenoid switch suitable for 45 kva to 125 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 7.5 kva to 62.5 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of radiator fan v belt set suitable for 75 kva to 250 kva ea set incl. testing , commissioning etc. as reqd. , providing and fixing of ignition switch or push button for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of engine start key switch incl. testing , commissioning etc. as reqd. , providing and fixing of oil pressure guage for ea set incl. testing , commissioning etc. as reqd. , providing and fixing of water temperature guage for ea set incl. testin
Tender For corrigendum : replacement of existing acsrpantherconductor of 132kv lines with htls conductor (except gap type) including design manufacturing testing supply of htls conductor along with suitable hardwares accessories on turn-key basis