Web Analytics Made Easy - StatCounter

Acsr Panther Conductor Tenders

Get complete information related to latest Acsr Panther Conductor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Acsr Panther Conductor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Acsr Panther Conductor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :44003370 Due date: 24 Feb, 202624 Feb, 2026 NA
Tender For auction sale of conductor & cables etc,earth wire / g.i wire / stay wire & 66kv g.i. tower material,66 kv class ct,66 kv class pt,66 kv sf6 circuit breakers,220 kv c.b single pole 2000 amp,disc /pin type porcelain insulator,220 kv ct,220 kv bushing,220 kv class cvt,66 kv bushing,66 kv pi support,11 kv ctpt unit,11 kv transformer 50/63 kva (oil type),11 kv transformer 100 /150 /160 kva (oil type),11 kv rmu panels with breaker & disconnect of switches.,m.s. material scrap etc,meter scrap as per lot description,electro mechanical energy meter 3 phase (metal body),70/150/250 watt hpsv fixture sheet / cast aluminum body & led,led 12 to 50 watt street light fixture&solar street light battery box,400 watt mh & hpsv flood light fixture cast aluminum body,frp street light junction box (plastic),400 watt mh control gear box cast aluminum body,85 to 120 watt fl t-5 fixture sheet aluminum body,street light junction box metal,used power transformer oil store in barrel,mcb with box (sheet metal),empty oil barrel ms,3-phase ht/lt electronic energy meter (plastic body),11 kv disconnector panel (without ocb)&11 kv rmu panel with oil circuit breaker

State Government

CTN :44015416 Due date: 28 Feb, 202628 Feb, 2026 10.42 Lacs
Tender For capital works-renovation works for effective power evacuation from newly constructed 2 mdmr feeder- enhancing the capacity of 110kv bus with triple bersimis acsr conductor at 220kv substation, malaparamba- part-c- stringing of bus

CTN :43985619 Due date: 26 Feb, 202626 Feb, 2026 3.24 Lacs
Tender For repair/ maintenance of o/h 440 volts line at regional store and rcc jrd with restringing of conductor, stay set, insulator change and pole painting work etc for provision of uninterrupted power supply from old substation jarandih to rcc and regiona

Central Government/Public Sector

CTN :43205972 Due date: 16 Feb, 202616 Feb, 2026 NA
Tender For bid to ras corrigendum : supply of c73340100470 supply of cassette ac four way capacity 2 tr minimum 5 star rating refer annexure ii-a , 100000000000 supply of suitable size refrigerant grade copper piping between indoor and outdoor units for 2tr cassette acorsplit ac unit refer annexure ii-a , 100000000001 providing flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure ii-a , 100000000002 providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-a , 100000000003 providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-a , 100000000004 supply of following size lt power cable with copper conductor xlpeorpvc insulation refer annexure ii-a , 100000000005 supply of copper cable of size 4 core - 2point5 sq mmfor communication refer annexure ii-a , 100000000006 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure ii-a , 100000000007 installation testing and commissioning of cassette ac four way capacity 2 tr minimum 5 star rating refer annexure ii-b , 100000000008 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units for 2 cassette ac unit refer annexure ii-b , 100000000009 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure ii-b , 100000000010 laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-b , 100000000011 laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure ii-b , 100000000012 laying of following size lt power cable with copper conductor refer annexure ii-b , 100000000013 laying of copper cable of size 4 core - 2point5 sq mm for communication refer annexure ii-b , 100000000014 installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure ii-b , 100000000015 dismantling and shifting of existing cassette ac 4 nos including associated supprots cu piping etc refer annexure ii-b

CTN :43988844 Due date: 05 Mar, 202605 Mar, 2026 NA
Tender For supply of w10-667-000018 curve set drawing lrrugular , w10-iwj2332 moderating glass green , w10-6675-000028 pen curved 125mm , x2-misc-1430-333-074-60 earthing cable , w2-wa-cx-ff-12 nut rifle no point 5 point hd , v4-1220000023 board plotting aa no 2a mk 1 , x2-misc-6553-101001-16 neon lamp , w10-7920-000278 brush pen cleaning special , v5-5340-175372 clamp , w10-6675-000023 dividers drafting proportional , y3-6145-001365 cable electrical atc elastomer insulate star , z3-nd-zc-26189 strip terminal 9-point 5 point 3 oblique 8- in x star , w106675-000252 rule slide gcr , w10-6675-000631 plate figure up- right12-0 mm , w10-6675-000637 pen lettering deluxe no-2 , y3-6145-007495 cable power electrical copper conductor star

Corporations And Associations And Others

CTN :43975417 Due date: 19 Feb, 202619 Feb, 2026 1.90 Lacs
Tender For supply of electrical materials for day-to-day maintenance in ward no. 17 under clz. - supply of 6- 32 amps rating, sp mcb, c curve, 10 ka breaking capacity., supply of 6- 32 amps rating, dp mcb, c curve, 10 ka breaking capacity., supply of 40 amp, 2 pole isolator ., supply of 63 amp, 2 pole isolator ., supply of 63 amp, 4 pole isolator ., supply of 100 amp, 4 pole isolator ., supply of pvc batten / angle holder., supply & fixing following piano type switch/socket on the existing switch box/cover including connections etc.as reqd.a) 5/6 amp.switch, 3 pin 5/6 amp.socket outlet, b) 15/16 amp.switch, c)6 pin1 5/16 amp.socket outlet, supply of ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. metal( aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/al body power factor not less than 0.9, service value (cm/m/w) minimum as below, 350 rpm (tolerance as per is : 374-2019), thd (total harmonic distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac ceiling fan compliant to is 374:2019 fan supply, earthing etc. complete as reqd. 1200mm, bee 5 star rating, service value 6.0 cm/min/watt, air delivery 210 cm/min (minimum), supplying of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80 , flicker free (flicker should be below 5 %), life time (led,driver & electrical circuitary), of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin), sdcm(standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy >135 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c).powder coated die cast /extruded aluminium body (thickness > 1.20 mm18- 22 watt, supply of 9 watt led retrofit lamp suitable for b22 holder, supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required., supply of pvc insulated and fr pvc sheathed multicore copper conductor 1.1kv grade, conforming to grade is 694 as required . 3*1.5 sq.mm

corporations/Associations/Others

CTN :44007662 Due date: 20 Feb, 202620 Feb, 2026 9.33 Lacs
Tender For supply and installation of insulation boot with nut bolt for busbar, la, bushing, jumper conductor etc. for power transformers at electric lane ptr1 and ptr2, hanuman road ptr1, tilak marg ptr2 in m-33kv division, ndmc.

CTN :43638150 Due date: 20 Feb, 202620 Feb, 2026 1.92 Lacs
Tender For corrigendum : advance e-tenders are invited for the material required for smooth running of t/wells under 52 no and 13 no out of 19 no twell scheme of garhshankar pwrmdc ltd., sub division of nurpur bedi block of distt. ropar - bch make 40 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3, bch make 40 amp duros freedom series 3 pole ac control contactor size -g cat no ce15kn-3 nb, bch make spare magnetic coil f series size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make pneumatic timer time delay relay time range 0.05-30 sec cat no krtpn10-0 ac control, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-2 size fr-2cat no ss90701, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type mnx-32 size fr-2 cat no cs94111, l&t make 3 pole power contactor type mnx-40 size fr-2 cat no cs94190, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 100 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-2 cat no 5595309, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type mnx 32 cat nocs94128, l&t make spare contact kit type mnx 40 cat nocs94147, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, l&t make thermal overload relay type mn5 range 45 75 amp cat no ss9413700j0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 100 amp 415 volt with extension strip, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 4 mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 6 mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10 mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 7/16mm, pvc wire 7/64, shunt capacitor with clamp l&t make 8.33 kvar, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, main switch on/of l&t mark 100 amp 3pole, push button l&t red, yellow, green, blue, overload relay l&t30-50- amp, overload relay l&t 28-42 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 0.1 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, terminal block 100 amp 3 way l&t, boparai basp-0708a single phase preventer

corporations/Associations/Others

CTN :44002923 Due date: 18 Feb, 202618 Feb, 2026 NA
Tender For auction sale of earthwire, gs, 7/3.225mm,conductor, acsr panther,pt, 36kv, 100va,pt, 145kv,surge arrestor, 120kv,panel, rtcc, 145/36kv, 20mva t/f,oil temperature indicator,relay, buchholz,ct, wti,empty oil drum,bushing, transformer, 245kv, 100mva,fitting, single tension, tarantulla,power supply card, cfe/vme_scrp,battery, vehicle_scrp,relay, distance protect, 21, numerical_scrp,scrap iron,earthwire_scrp,jaw, isolator, 145kv, 1250a, female,vcb, 36kv, 1600a, 26.3ka/3sec,ct, 36kv, 100-50/1a, 1c,ct, 36kv, 400-200/1a, 2c,isolator, 36kv, 1250a, w e/s,vibration damper, earth wire, 7/3.225mm,water purifier,structure, alp, la/pi_scrp,relay, o/c & e/f protect, 50/51, e/m_scrp,relay, master trip, 86_scrp,isolator, 66kv_scrp,jaw, isolator, 36kv, 1250a_scrp

CTN :43638147 Due date: 20 Feb, 202620 Feb, 2026 3.68 Lacs
Tender For corrigendum : advance e-tenders are invited for material required for smooth running of t/wells under 91 no,25no,23no, 1 no out of 19 no and 41 no. scheme under 502 no deep t/well scheme of nawanshahar pwrmdc ltd.,sub division of distt. sbs nagar under bdc-1 division, ropar - bch make 110 amp duros freedom series 3 pole ac control contactor size -g cat no bch15mt-3-11, bch make spare magnetic coil size g,j,j,kcat no mc15kw, bch make spare magnetic coil size d,e,fcat no mc15fw, bch make ct operated overload relay range 37.6-60.0 amp cat no ct2 mc305ana3c, bch make ct operated overload relay range 56.4-90.0 amp cat no ct3mc305ana3c, bch make pneumatic timer time delay relay time range 0.05-60 sec cat no krtpn10-1 ac control, l&t make 3 pole power contactor type ml-3 size fr-2cat no ss90721, l&t make 3 pole power contactor type ml-4 70 amp size fr 3cat no ss90910, l&t make 3 pole power contactor type ml-6 size fr-3cat no ss90921, l&t make 3 pole power contactor type mnx-50 size fr-3 cat no cs97075, l&t make 3 pole du mccb breaking capacity 180 amp cat no cm980610000, l&t make spreader terminal for du250 3 pole mccb cat no st980530000 set of 6, l&t make spare contact kit type ml-3 cat no 5595309, l&t make spare contact kit type ml-4 cat no 5595311, l&t make spare contact kit type ml-6 cat no 5595313, l&t make spare contact kit type mnx 50 cat nocs94150, l&t make spare coil type ml3 cat no ss90545, l&t make spare coil type ml4 cat no ss91258, spare coil ml6 125amp, l&t make thermal overload relay type mn5 range 45-75 amp cat no ss9413700, l&t make thermal overload relay type mn5 range 66-110 amp cat no ss9413700k0, fuse unit gkh kit kat porcelain rewirable type conform to is2086/93 200 amp 415 volt with extension strip, kitkat 200 amp max, kitkat 500 amp max, copper thimble 100 amp, copper thimble 200 amp, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 25mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 16mm2, finolex make 3 core flat cablewith bare bunched copper conductor insulated with pvc and sheathed with pvc for submersible pump motor with voltage grade upto 1100 volts generally confirm to is 694;1990 size 10mm2, pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is 694 with latest ammendment size 19/16mm, al thimble, shunt capacitor with clamp l&t make 10 kvar, shunt capacitor with clamp l&t make 12.5 kvar, shunt capacitor with clamp l&t make 15 kvar, shunt capacitor with clamp l&t make 20 kvar, shunt capacitor with clamp l&t make 25 kvar, push button l&t red, yellow, green, blue, overload relay l&t 40-80 amp, overload relay l&t 20-60 amp, gic timer l&t 0.1sec to 10 hrs, gic timer l&t 30 sec to 120 sec, voltmeter 0-500 volt, ammeter 0-300 amp, ammeter 0-500 amp, ct voltmeter + ammeter combined, terminal block 100 amp 3 way l&t, pvc wire 7/64, control panel l&t make 50 hp, control panel l&t make 75 hp, boparai basp-0708a single phase preventer
 Loading, Please wait...

Connect us via What's Up