Tender For flood resilience enhancement of gs road, rukminigaon via aquifer recharge and flood wall (construction of flood protection wall from along bahini river from rukminigaon pibco point upto janata bhawan on gs road)
Tender For construction of r/wall at rd 4/030 to 4/047, b/wall at rd 4/050 to 4/062, r/ wall at rd 4/00 to 4/015 and wire crate for protection of slab culvert
Tender For construction of cc protection wall from bridge to h/o gulzar lone supply of kabir lone at lone mohallah gujran panchayat gujran block tulail
Tender For special repair of session judge residence building at tarna district mandi h.p. (sh- providing protection work b/wall, flooring and cement plasters work etcetera) under d.no. 3 head 2059, 4th call
Tender For construction of boundary wall with gi chain link fencing on river side near girls hostel for protection of campus at jnvb pandoh district mandi h.p. deposit work 3rd call
Tender For corrigendum : supply and installation of ip54 protected glass fiber reinforced polycarbonate double insulated power distribution board of dimension 1200 x 1300 x 274mm. the enclosure must be of double insulated, haloge free with high impact resistance of ik08 (5 joules) according to iec 62262. the enclosure should be made of uv resistant material, corrosion free. the enclosure material used should be self-extinguishing up to 960 deg with working temperature from -35 degc to +80 degc. interconnection between the enclosures in the panels should be made with accessories which should maintain with same ip protection rating of ip65. the enclosure gasket materials shall be injected polyurethane. the enclosure should be made of the same polycarbonate materials only. incomer: 400a fp mccb 36ka - 1 no and 230v ac r,y,b indicating lamp, digital multi-function meter with 400/5a current transformer and outgoing: 100a tp mccb 36ka with 100a neutral link - 7 nos & 63a fp mcb 10ka - 2 nos with 70a tp ac3 contactor control with 24hrs digital timer with auto/manual selector switch and push buttons for manual operations .copper busbar rating of 400a - 30 x 10 for all phases and neutral should be used -provision for termination of 185 sq.mm in incomer and 35 sq.mm cables for 100a outgoing, 16 sq.mm cables for 63a outgoing and all mccb should have an adjustable setting range (in) from 70% to 100%, each mccb should have extended rotary handle for easy operation. the manufacturer should submit all the test certificates in accordance with iec 61439, routine test report must be made with high voltage test, insulation resistance test, functional test. the wall mounting frame should be made of hot dip galvanized materials. 1) acceptable make :cape/ famatel/hensel/rittal/abb with following switch gear and terminals fixed in the junction box as per drawing enclosed. 2)terminal block make: connect well/ elmex. 3)switch gears make shall be abb/l&t /eaton/siemens,havells,c&s. [ warranty period: 12 months after the date of delivery ]
Tender For repairs and replacement of plumbing and sanitary fittings floor and wall tiles false ceiling plinth protection aluminium joineries periodical services and other miscellaneous repair works at rtc and directors enclave at zone a and casdic bso west and dsc l