Tender For repair replacement of water filtration plant control valves ps tank storage tanks staging filter media and connected items at phase i rupa gachham birpur dp bomdila of age em under ge tenga
Tender For corrigendum : supply of control valves for lara singrauli and talcher projects - lara-cv-asv-8, dea pegging from aux. steam header , lara-cv-crhv-6, dea pegging from crh line , lara-cvcdv-25, low load condensate control , lara-cvcdv-39, gsc min. flow recirculation , lara-cv-cdv65, cep-a min. flow recirculation , lara-cv-cdv-67, cep-b min. flow recirculation , lara-cv-cdv-69, cep-c min. flow recirculation , lara-cv-cdv-43, excess dump control , lara-cv-cdv-72, condensate for valve gland sealing and flash tank , lara-cv-cdv84, condensate spray for flash tank , lara-cv-cdv94, condensate spray for unit flash tank , lara-cvdrv-53, hph-9a normal drain to hph-8a , lara-cv-drv59, hph-9b normal drain to hph-8b , lara-cv-drv-56, hph-9a alt drain to flash tank , lara-cv-drv-62, hph9b alt drain to flash tank , lara-cv-drv-2, hph-8a normal drain to hph-7a , lara-cv-drv-8, hph-8b normal drain to hph-7b , lara-cv-drv-5, hph-8a alt drain to flash tank , lara-cv-drv-11, hph-8b alt drain to flash tank , lara-cv-drv-15, hph-7a normal drain to deaerator , lara-cv-drv-22, hph-7b normal drain to deaerator , lara-cv-drv-18, hph-7a alt drain to flash tank , lara-cv-drv-25, hph-7b alt drain to flash tank , lara-cv-drv-82, lph-5 normal drain to lph-4 , lara-cv-drv-85, lph-5 alt. drain to flash tank-b , lara-cv-drv-65, lph-4 normal drain to lph-3 , lara-cv-drv-68, lph-4 alt. drain to flash tank-b , lara-cv-drv-77, drip pump discharge control , lara-cv-drv-31, lph-3 alt. drain to flash tank-b , lara-cv-drv-48, deaerator overflow to flash tank-b , lara-cv-dmv-43, normal dm mu to hotwell , lara-cv-dmv-78, emergency dm mu to hotwell , lara-cv-asv-16, drain of aux steam from existing unit header to unit flash tank , lara-cvdmcwsg12, dmcw system for sg aux , lara-cvdmcw18, dmcw system for tg aux , lara- one fourth inch ss tubing -12 meter for each tag , lara- ss fittings for connection to air filter regulator- for each tag , lara- ss fittings for connection to air lock relayfor each tag , lara- ss fittings for connection to ia header isolation valve - for each tag , lara- ss equal tee - for each tag , lara- ss half inch npt m x one fourth inch od tube connector- for each tag , lara- commissioning spares gaskets and gland packing set for each valve , lara- valve diagnostic and configuration software , lara- cv test charges , lara- mandatory spares- pneumatic and electro hydraulic actuator assembly or equivalent item applicable for selected actuator type shall be provided, 1 no. of each type model and rating , lara- mandatory spares- diaphragms, o rings, seals etc.- 5 nos. of all types make etc. , lara- mandatory spares- solenoid valves if applicable - 1 no. of each type , lara- mandatory spares- smart positioners complete unit and accessories link assembly - 2 nos. of each type, model and rating , lara- mandatory spares- pneumatic air filter or regulator- 2 nos. of each type, make rating etc. , laramandatory spares- air lock relays- 1 no. of each type, model and rating , lara- mandatory spares- valve trim - including cage, plug, stem, seat rings, guide bushings etc. - 1 set for each type,class,size of control valve , lara- mandatory spares- gland packing- 5 sets , lara- mandatory sparesgaskets- 5 sets , lara- mandatory spares- cep recirculation valve trim which includes spindle with cone, seat ring, guide bush, cage- 1 set , lara- mandatory spares- cep recirculation valve soft parts i.e. gland packing, seals, orings, gaskets etc.- 3 sets , lara- mandatory spares- ss fittings for connection to air filter regulator- for each tag- 100 nos. of each type , lara- mandatory spares- ss fittings for connection to air lock relay- for each tag100 nos. of each type , lara- mandatory spares- ss fittings for connection to ia header isolation valve- for each tag- 100 nos. of each type , lara- mandatory spares- ss equal tee- for each tag- 100 nos. of each type , lara- mandatory spares- pneumatic air filter or regulator- 20 nos. of each type and model , laramandatory spares- v
Tender For restoration of rain damages to wss bhosh in gp sarsei in tehsil manali distt. kullu h.p. (sh:-plastering/jacketing of storage tank, masonary work & fitting of filter bed).
Tender For restoration of rain damages to wss gurdour in g.p. larankelo in tehsil & distt kullu h.p. (sh:- plastering/jacketing of storage tank, providing and fixing fitting at filter bed nashal gourdor & larankelo)
Tender For a/r & m/o lwss kurpan khad to banokhari g/o villages tehsil nankhari distt. shimla hp (sh:- finishing wall with water proofing cement, distemper & painting and taking out deposit silt in raw water tank and removal of slip sides of back wash tank & rapid sand filter in treatment plant at duttnagar.
Tender For supply of spark plugs are not working to be replaced , controle cables need to be replaced , battery switch is not working to be repaired or replaced , prime bulb is not working to be replaced , water separator is not working to be repaired or replaced , toggle switch is not working to be rectified or replaced , bilge pump is not working to be repaired or replaced , fuel filter is fully rusted need to be replaced , gear oil leakage is observed and work for the same need to be carried out , position sensor need to be repaired or replaced , back line water line hose and clips are damaged and the same to be replaced , battery leg and terminals are damaged and need to be replaced. , check valves need to be replaced , batteries are not holding charge due to the battery cables need to be check if require the same to be rectified or replaced , fuel hoses from main tanks to ru tank need to be check if require the same to be rectified or replaced , horn is not working to be replaced , ignition coils is not working to be replaced , some hose clips need to be replaced , antifouling paint work need be carried out to enhance a vessels performance and durability