Tender For installation of aluminium composite panel and glass cladding on the control room building front exterior face and erection of perforated gi cable tray of different size with electrical works at the pirpukur substn under garia div civil and elec
Tender For supply of 1 - cable tray assy. var 01 which consist of item 2 and 5 as per drg no. 34996500005 rev 08 , 2 - cable tray assy. var 02 which consist of item 3 and 6 as per drg no. 34996500005 rev 08
Tender For supply of supply of ductible split ac , itc of sac , pdg. and installing copper pipe , sitc of rigid u pvc piping , supplying and fixing of iron stand , supplying and installing perforated m.s. cable tray , supply copper armoured power cable , supply copper unarmoured power cable , supplying and fixing sp mcb db , supplying fixing mcbs c curve , supplying fixing isolator , supply aluminum armoured power cable , laying of xlpe power cable , supplying and making end termination
Tender For high frequency x-ray machine-, , , high frequency x-ray machine suitable for general radiography., , x-ray generator:, , high frequency x-ray generator having frequency of 50khz should be provided., , oil filled based generator for high dielectric strength, better heat dissipation, and easy service stability., , power output of generator should be 40 kw., , radiographic kv range should be 40 to 125kv., , ma range (rad.): upto 500ma., , exposure time (rad.): 2ms to 2sec., , mas range (rad.): 1 to 200mas., , control:, , a very compact, soft feather touch control panel having following functions & indications should be provided. the panel can be supplied in floor mount with spill proof design., , following features should be available on the control panel., , machine on/off switch., , digital display of kv & mas., , kv & mas increase and decrease switches., , tube focal spot selection switch., , ready and x-ray on switch with indicators, , bucky selection switch., , self diagnostic programme with indicators for earth fault error, kv error, filament error & tube's thermal overload., , anatomical preprogrammed parameters of human anatomy should be available to select exposure parameters based on body part, examination view and size of the patient., , anatomical programming up to 200 programmes or more, , a dual action hand switch with retractable cord should be provided for radiation protection of operator., , x-ray tube:, , one no. dual focus rotating anode x-ray tube thermally protected., , anode heat storage capacity of tube should be 140 khu., , one pair of 8-meter h.v. cable., , one no. collimator with auto shut off facility, should be provided., , hv tank:, , a very compact h.v. tank filled with high dielectric transformer oil should be provided. the h.v. tank should contain h.v. transformer, filament transformers, h.v. rectifiers & h.v. cable receptacles., , tube stand:, , floor mounted ceiling free tube stand with counter balanced movements & with easy installation at site., , manual movements with electromagnet locks in longitudinal, transverse & vertical movements are provided with release switches on electromagnet panel mounted on tube collimator assembly., , tilto meter on electromagnet panel to show tube angle position., , continuous tube rotation around horizontal axis with lock, , f. table:, , floatex table with 4-way movement of the table top i.e. along x axis and y axis is to be provided. longitudinal movement of tabletop is 500mm or more & transverse movement is 180mm or more., , the table should consists of bucky motorized reciprocating grid of ratio 8:1 - 85 lines/inch., , the bucky should be locked at any desired length position by an electromagnetic lock., , the tabletop should be made of low radiation absorption, waterproof material., , table accessories like stainless steel cassette tray, compression band is to be provided., , g. vertical bucky stand:-, , vertical bucky stand with oscillating grid of ratio 8:1, 85 lines / inch is provided., , the bucky moves up & down & is equipped with a stainless steel cassette tray., , the stand is floor-mounted type & can accommodate cassettes up to 14" x 17". the bucky is tilted in 6 steps of 15 degree angle each for various radiographs., , vbs should have provision for without grid exposure., , power requirement: the unit should be, , operable on 3 phase, 400 volts ac 50hz with line resist less than 0.2 ohms. line regulation 10%., , other requirements:, , the company should be iso & icmed certified company., , the unit should be approved by aerb., , the company should be european ce certified from notified body., , the equipment should have import/manufacturing, ,
Tender For supply, installation, testing & commissioning of (150 mm width x 50 mm depth x 1.6 mm thi ckness) perforated hot dipped galvanized iron cable tray (galvanization thickness not less than 50 micron s) with perforation not more than 17.5%, in convenient sections fixed with ms angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect. [ warranty period: 30 months after the dat e of delivery ]
Tender For tender for supply of frp handrail frp gratings and frp cable tray - frp handrail details as per sl no 1 in boq , frp pultruded grating 800x800mm details as per sl no 2 in boq , frp pultruded grating 1000x1000mm details as per sl no 3 in boq , frp cable tray 450x100x5mm details as per sl no 4 in boq , frp cable tray 350x75x4mm details as per sl no 5 in boq