Tender For supply & establishment of sterile department of rims teaching hospital, raichur on turnkey basis-automated 1000 lph ro water plant with pre-treatment setup and 3000 liters ss storage tank, mild steel shed, required electrical work, plumbing for ro plant supplier should supply the 1000 lph ro water plant with pre-water treatment setup and 3000 liters ss storage tank and plumbing work from building top to the ground floor sterile department and required electrical & civil work for proper installation & commissioning of ro plant 1 bulksupply and installation of duct/cassette a/c's and internal electrical wiring and other, wherever required 5.5 ton supplier should supply & install suitable for sterile department, the 5.5 ton duct a/c's to sterile area, non-sterile area, packaging area, receiving area and washing area and make internal electrical wiring etc for proper installation of reputed company duct a/c's 3 bulkss cladding for sterile room, non-sterile room and air tight room supplier should make ss cladding for sterile room : 30f x 14f and non sterile room : 60f x 14f with three doors 1 bulkgood quality upvc/equivalent false ceiling, led lighting and required electrical wiring a good quality and reputed company upvc/equivalent false ceiling of 2x2 size plates with 2x2 led lighting plates and required electrical wiring should be done of total area : 4000 sq.feet 1 bulkanti-bacterial 2mm vinyl flooring with proper installation a good quality and reputed company anti-bacterial 2mm vinyl flooring with proper installation should be done of total area : 4000 sq. feet 1 bulkplumbing work for drain pipe connections and other, wherever required plumbing work-drain pipe connections and related work, wherever required should be done the bidder 1 bulkvitrified tiles for walls of sterile room & non-sterile room a good quality and reputed company vitrified tiles for walls of sterile room and non-sterile room of total area : 3000 sq. feet 1 bulksupply and proper installation of modular kind main door and back door a good quality modular kind of main door of size : 10f x 7f+2f name board and back door of size : 4f x 7f +2f name board 2 nosname boards & signage boards etc wherever required a good quality signages and name boards should be done, wherever required 1 bulkanti-bacterial painting for entire sterile department with premium good quality wall paint with lupum, wherever required a good quality and reputed company premium anti-bacterial wall paint with lupum should be done of total : 4000 sq.feet 1 bulkcivil work-wall breaking, wall construction, door shifting, plastering and other 1) receiving area : wall hole making for pass box and other work 1 bulk 2) sterile area : removing of existing door, wall construction, plastering and other work 1 bulk 3) sterile storage room : wall construction, plastering and other work 1 bulk 4) distribution room : wall breaking, plastering, door installation and other work 1 bulk 5) scrub area : removal of existing door, wall construction and plastering and other work 1 bulk 6) washing area : wall hole making for drain pipe installation and other work 1 bulk 7) if any other civil work required for proper installation, commissioning of sterile department is should be bidder scope only 1 bulkanti-bacterial painting & any carpentry work of existing doors 1) sterile storage room : door painting 1 no 2) distribution room : door painting 1 no 3) changing room : door painting 1 no 4) non sterile room : door painting 1 no 5) packaging room : door painting 1 noheavy duty ceiling fans and switches, sockets ,dimmer, surface boxes etc bidder should supply & install the heavy duty ceiling fans and switches, sockets ,dimmer, surface boxes etc wherever required 1 bulkcad drawing and detailed report with labelling with signature the bidder should visit our proposed site before quoting the tender and design the work flow as per the nabh/nhsrc/nqas of sterile department with desired layout
Tender For job (a) preventive maintenance of 3.3kv, 400a, ctr 200:100:5, biecco lawrie make ocb at electrical sub-station, (b) fabrication of distribution/ panel board for providing power with safety to welding machine, compressor, lightning etc. with appropriate switch/breaker at workshop, barmuri oc, mugma area, ecl.
Tender For corrigendum : supply of t bulb (q4) , modular electrical enclosure switch board boxes for modular type accessories (q3) , led bulkhead light (q3) , varnishes or shellac varnish as per is 347 (q3) , miniature circuit breakers distributionboards as per is 13032 (q3) , textile floor covering - handmade wool carpet (v2) as per is 5641 (q3) , led bulb with battery as per is 16102 (q3)
Tender For electrical repairing / re-wiring and changing of electrical items of 9.0 office, konar river side pump house (2 nos.) and civil office under kathara colliery. - wiring for light point /fan point/exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduct, with piano type switch, phenolic laminated sheet, suitable size m.s box and earthing the point with 1.5sq.mm frls pvc insulated copper conductor single core cable etc. as required. group a , supplying & erection of stay set complete (galvanized) with 19/20 mm dia x 1.8 meters long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm, thimble, stay clamps, turn buckle (20 mm x 60cm), 7/4.00 mm dia g.i stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 oarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling as required. 2. group b , wiring for light point /fan point/exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduct, with piano type switch, phenolic laminated sheet, suitable size m.s box and earthing the point with 1.5sq.mm frls pvc insulated copper conductor single core cable etc. as required.3. group c , supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings)., supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings)., supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 1). 5/6 amps switch, supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 2). 3 pin 5/6 amps socket out let, supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 3). 15/16 amps switch, supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 4). 6 pin 15/16 amps socket out let, supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required., supplying and fixing followings way, single pole neutral, sheet steel, mcb distributionboard, 240 volts, on surface / recess, completed with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb/rccb/isolator).i) 2 + 4 way / 8 way, double door, supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inclusive for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. i) single pole and neutral., wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc consult as required. i). 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire, wiring for circuit / sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc consult as required. ii). 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire, wiring f
Tender For nit 313/supply of electrical line materials under oandm head for f.y. 2024-25 under esa, giridih. - electrical items :, danger board 33 kv/11 kv/ lt, led flood outdoor light with ip 66 protection rectangular [100w], male female contact of 33 kv ab switch 600-630 amp., male female contact of 11 kv ab switch 600 amp., male female contact of 11 kv ab switch 400 amp., insulation piercing connector brancing suitable for t joints, spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cabel and three phase connection 1 incoming and out going 3-phase connection as per field requirement, lt phase sepeator, polycarbonate seal bit.specification:-1. anchor type four lock.2. sealing wire should be embaded in female part.3. seal bit should be two part male & female.4. serial no. should be emossed not printed.
Tender For corrigendum : supply of split air conditioner including green ac, wall mount type (v2) (q2) , non - modular piano type domestic electrical switches as per is 3854 (q3) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , propeller type ac ventilating fans - exhaust fans (v2) as per is 2312 (q2) , miniature circuit breakers distributionboards as per is 13032 (q3) , plug and socket distributionboard (q3)
Tender For providing incoming power supply cable and cubical type distribution panel board with necessary earthing arrangements to the electrical machines laboratory in the ground floor of department of electrical and electronics engineering, anna university, chennai-25.
Tender For providing electrical installations for proposed new pgmt office at main te building belagavi. - ei & fans, wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size ms box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required.(a) group b, wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 no 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit along with 2 nos 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required., wiring for circuit/ submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required (a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, (b) 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire, (c) 2 x 6 sq. mm + 1 x 6 sq. mm earth wire, supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings)., supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required., supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required., installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/led fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required., installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required., installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(a)upto 450 mm sweep, supplying and fixing following way, single pole and neutral, sheet steel, mcb distributionboard, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) (a)2 + 6 way, double door, (b)2 + 8 way, double door, supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distributionboard, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) (a)4 way (4 + 12), double door, supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.(a)single pole, (b)double pole, triple pole and neutral, supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "c" curve dp mcb complete with connections, testing and commissioning etc. as required., providing and fixing 4.00 mm dia copper wire on surface
Tender For removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., lt panel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way lt distribution panel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of lt distribution panel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distributionboard as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distributionboard as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end termination kit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & boat, suitable