Web Analytics Made Easy - StatCounter

Electricity Distribution Tenders

Get complete information related to latest Electricity Distribution Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electricity Distribution Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electricity Distribution Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39864916 Due date: 08 Apr, 202508 Apr, 2025 NA
Tender For replacement of existing ab cable/weasel conductor with various size 3 phase lt ab cable at 33/11 kv substation, kotabag selsiya feeder under electricity distribution division ramnagar.

State Government

CTN :39864921 Due date: 08 Apr, 202508 Apr, 2025 NA
Tender For replacement of existing ab cable/weasel conductor with various size 3 phase lt ab cable at 33/11 kv substation, kotabag patkot feeder under electricity distribution division ramnagar.

State Government

CTN :39864065 Due date: 04 Apr, 202504 Apr, 2025 2.50 Lacs
Tender For purchase of general items/electricity, water and wooden items for office use - mascot night /all out refill 45 light (company make) , maskut night/all out machine with refill (company make), , jug plastic 1.5 liter (company make), , room perfume refill (company make), , room perfume machine with refill(company make), , lock (big size) (company make), , hand wash soap 100 g, , dishwashing soap 100 g, , car spray (company make), , name plate acrylic found plate (4"x14"), , name plate bakelite acrylic plate (6" x 28"), , name plate stand (iron), , glass of water (equivalent to yera), , glass of water (equivalent to borosil), , cup set superior quality, , service tray superior quality, , thermos 1 liter superior quality, , thermos 2 liter superior quality, , napkin superior quality, , tawal superior quality (white colour full size), , computerized rubber stamp rates per line., broom flower, , big broom, , mop, , harpik, , camphor tablets, , odonil, , plastic umbrella, , phenyl, , brush, , wiper, , plastic bucket including jug., , led bulb 05 watt, , led bulb 07 watt, , led bulb 09 watt, , led bulb 20 watt, , led bulb 40 watt, , led tuble light set 20 watt, , led tuble light set 40 watt, , extension board (wooden) power shockit/switch 4, , including shock kit, 4 switches with 3 meter 2.5mm wire, , extension board (wooden) power shock absorber / switch 3 shock absorber, 3 switches with 3 meter 2.5mm wire, , regulator (ceiling fan), , switch 5 amp, , shockit 5 amp, , switch 15 amp, , shockit 15 amp, , tape roll small (for light use), , wire 1mm(copper) rate per fit, , wire 1.5mm(copper) rate per fit, , wire 2.5mm(copper) rate per fit, , wire flexible (copper) rate per fit, , sri pin 5 amp, , multi plug 6 amp, , ac condenser shock absorber with top- ???????? ????? ???? ???? ??????/??????? ? ???? ??? ???? ?? ????? ????

corporations/Associations/Others

CTN :39717779 Due date: 01 Apr, 202501 Apr, 2025 10.00 Lacs
Tender For corrigendum : the work of transferring 33/11 kv lt lines under the full deposit scheme head of 33/11 kv sub-station under the electricity distribution division modinagar/muradnagar.

corporations/Associations/Others

CTN :39878028 Due date: 05 Apr, 202505 Apr, 2025 3.00 Lacs
Tender For providing 1 no. diesel car with driver for s.e., electricity distribution circle-ii, prayagraj

corporations/Associations/Others

CTN :39863809 Due date: 16 Apr, 202516 Apr, 2025 2.42 Crore
Tender For providing, laying & shifting of power line at industrial area chauhtan.

State Government

CTN :39878614 Due date: 28 Apr, 202528 Apr, 2025 1257.48 Crore
Tender For selection of solar power generators (spgs) on the basis of build own & operate (boo) for design, survey, supply, installation, testing, commissioning, operation & maintenance of grid connected distributed solar power plants for solarization of selected 86 nos agriculture feeders at 22nos of sub-station(ss) level with capacity of 99.41 mw in gescom jurisdiction totally covering 31821 nos of ip sets and its associated 11kv line to connect the plant with concerned sub station(ss) and remote monitoring system (rms) of solar power plants through resco mode, for 25 years under component c-feeder level solarization of pm-kusum scheme

CTN :39862703 Due date: 02 Apr, 202502 Apr, 2025 2.64 Lacs
Tender For providing diesel vehicle for sub-divisional offier rudauli under electricity distribution division rudauli, ayodhya

CTN :39873723 Due date: 05 May, 202505 May, 2025 NA
Tender For provision of ups power supply and cable tray for telecom sub-system in blue line of metro railway, kolkata

CTN :39876029 Due date: 08 Apr, 202508 Apr, 2025 11.00 Lacs
Tender For high frequency x-ray machine-, , , high frequency x-ray machine suitable for general radiography., , x-ray generator:, , high frequency x-ray generator having frequency of 50khz should be provided., , oil filled based generator for high dielectric strength, better heat dissipation, and easy service stability., , power output of generator should be 40 kw., , radiographic kv range should be 40 to 125kv., , ma range (rad.): upto 500ma., , exposure time (rad.): 2ms to 2sec., , mas range (rad.): 1 to 200mas., , control:, , a very compact, soft feather touch control panel having following functions & indications should be provided. the panel can be supplied in floor mount with spill proof design., , following features should be available on the control panel., , machine on/off switch., , digital display of kv & mas., , kv & mas increase and decrease switches., , tube focal spot selection switch., , ready and x-ray on switch with indicators, , bucky selection switch., , self diagnostic programme with indicators for earth fault error, kv error, filament error & tube's thermal overload., , anatomical preprogrammed parameters of human anatomy should be available to select exposure parameters based on body part, examination view and size of the patient., , anatomical programming up to 200 programmes or more, , a dual action hand switch with retractable cord should be provided for radiation protection of operator., , x-ray tube:, , one no. dual focus rotating anode x-ray tube thermally protected., , anode heat storage capacity of tube should be 140 khu., , one pair of 8-meter h.v. cable., , one no. collimator with auto shut off facility, should be provided., , hv tank:, , a very compact h.v. tank filled with high dielectric transformer oil should be provided. the h.v. tank should contain h.v. transformer, filament transformers, h.v. rectifiers & h.v. cable receptacles., , tube stand:, , floor mounted ceiling free tube stand with counter balanced movements & with easy installation at site., , manual movements with electromagnet locks in longitudinal, transverse & vertical movements are provided with release switches on electromagnet panel mounted on tube collimator assembly., , tilto meter on electromagnet panel to show tube angle position., , continuous tube rotation around horizontal axis with lock, , f. table:, , floatex table with 4-way movement of the table top i.e. along x axis and y axis is to be provided. longitudinal movement of tabletop is 500mm or more & transverse movement is 180mm or more., , the table should consists of bucky motorized reciprocating grid of ratio 8:1 - 85 lines/inch., , the bucky should be locked at any desired length position by an electromagnetic lock., , the tabletop should be made of low radiation absorption, waterproof material., , table accessories like stainless steel cassette tray, compression band is to be provided., , g. vertical bucky stand:-, , vertical bucky stand with oscillating grid of ratio 8:1, 85 lines / inch is provided., , the bucky moves up & down & is equipped with a stainless steel cassette tray., , the stand is floor-mounted type & can accommodate cassettes up to 14" x 17". the bucky is tilted in 6 steps of 15 degree angle each for various radiographs., , vbs should have provision for without grid exposure., , power requirement: the unit should be, , operable on 3 phase, 400 volts ac 50hz with line resist less than 0.2 ohms. line regulation 10%., , other requirements:, , the company should be iso & icmed certified company., , the unit should be approved by aerb., , the company should be european ce certified from notified body., , the equipment should have import/manufacturing, ,
 Loading, Please wait...

Connect us via What's Up