Tender For supply of spare of lt vfd at hurl sindri on oem basis - dual temperature transmitter, filter capacitor for sine wave filter, current transformer ratio - 100/1a, vfd control device, vfd power device, hrc fuse link bs type, fuse holders & isolating link, hrc fuse bs type, fuse-link rating-80a, ac 690 v., fuse base nh din type, "6"" output filter ral 7035 size 6 incfan failure and temp detection unitiop (intelligent operator panel)power contactor rating-45a, 230v ac", "sine wave filter reactor rating -22kwpanel fanmulti-function meter (mfm)32-50 a, thermal overload relay""", circuit breaker with electronic trip, panel door mounted rotary op. handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, 5a, d series ac drm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs-4-20ma, motor restart timer, green push button & contact block, red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block., yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For supply of title - 120ah valve regulated maintenance free lead acid batteries set (each set comprising of 19 monoblocks of 6v, 120ah) for 110 v train lighting system complete with connectors and electrolyte in factory charged condition, conf. to rdso spec. no. rdso/pe/spec/ac/0009-2021 (rev -3) or latest. firm shall submit oem/authorized dealer certificate., supply of maintenance free vrla batteries of 48 volt/200 ah as per rdso specification no. irs:s 93/96(a) with amdt. 01 (each battery set shall be of 24 batteries of 2v/200ah). with all accessories, supply of 48v/50 amp (2+1) configuration modules of 25 amp each smps charger as per rdso/spn/tl/23/1999(ver4.0) latest, mcb 2 pole, current rating 10a, breaking capacity 10ka voltage rating 200v dc for power supply, sanitary control, loud speaker system, automatic sliding, door 1, infotainment system rating. conforming to item no. 24 of bill of material of rdso letter no. eli7.1.108/mssbc dated 17.09.2021 or latest, make- legrand, l&t, siemens, schneider, abb, eaton. firm shall submit oem/authorized dealer certificate., mcb 63a, 2 pole, 415v, 50hz, c curve breaking capacity 10ka is/iec 60898-1 2002 used in electric burner 4 at lhb a c pantry car confirming to rcf spec. edts 134, rev d. make: mds, legrand, aeg, moeller or as per latest bill of material of the above said specification. firm shall submit oem/authorized dealer certificate., miniature circuit breaker (mcb) voltage rating: 200v dc, 2 pole, current rating: 6a, breaking capacity- 10ka conforming to item no. 22 of bill of material of rdso letter no. eli7.1.108/mssbc dated 17.09.2021 or latest, make- l&t, siemens, schneider, abb, eaton. firm shall submit oem/authorized dealer certificate., mcb 3a, 200 v dc single pole, c curve, confirming to item no. 57 of bill of material of rdso letter no. eli7.1.108/mssbc dated 17.09.2021 or latest, as per legrand cat. no. 408802, abb-sb201-c3dc, siemens- 5sl51037rc, l&t-bb1003dc, schneider a9n61503 make abb. hsn code-85362030. firm shall submit oem/authorized dealer certificate., miniature circuit breaker (mcb) for power factor correction of cd & blower motor of lhb ac coaches having current rating 2.5/3a, voltage rating 415 vac, 3 pole, breaking capacity 10 ka, curve d, confirming to item no. 45 of bill of material of rdso letter no. eli7.1.108/mssbc dated 17.09.2021 or latest, make- legrand, siemens, abb, l&t or schneider only. firm shall submit oem/authorized dealer certificate., miniature circuit breaker (mcb) for power factor correction of compressors of lhb ac coaches having current rating 6a, voltage rating 415 vac, 3 pole, breaking capacity 10 ka, curve d, confirming to rdso letter no. eli7.1.108/mssbc dated 17.09.2021 item no. 46. make? legrand, siemens, abb, l&t, schneider. firm shall submit oem/authorized dealer certificate., motor protection circuit breaker (mpcb) for water pump mbs 25 with aux. contact (1no+1nc) and terminal block db, current rating: 1.6 a, thermal release range:1-1.6 a, class:10, breaking capacity: 50ka, pole: 3, voltage:415 vac, confirming to item no. 46 of bill of material of rdso/pe/spec/0184-2015(rev-2) or latest. accepted make & model: l&t/siemens/schneider/abb. firm shall submit oem/authorized dealer certificate., motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, confirming to item no. 39 of bill of material of rdso letter no. eli7.1.108/mssbc dated 17.09.2021 or latest suitable for use in switchboard cabinet of lhb type ac coaches. accepted make-abb, legrand, schneider, l&t, siemens, eaton. firm shall submit oem/authorized dealer certificate., mpcb for exhaust fan with auxiliary contact (1. no + 1 nc) and terminal block, rated current:0.63a, thermal release range: 0.4-0.63a, class:10, breaking capacity: 50ka, pole: 3, voltage: 415v ac confirming to item no. 50 of
Tender For supply of breakers - 11 kv ct swbd. incomer-breaker retrofit , 11 kv ct swbd. motor feeder retrofit , 11 kv ct swbd. trafo. feeder retrofit , 11 kv ct swbd. seht feeder retrofit , 11 kv ct swbd. bus-pt panel retrofit , installation testing commissioning of switchgear components for refurbishment of abb make 11 kv switchbaord at coastal terminal ht substation including retrofitting of existing sf6 circuit breakers with new vacuum circuit breakers vcbs panel control wiring modifications for numerical relay retrofit and conversion to 110 vdc auxiliary supply as per tender specifications scope of works and directions of engineerincharge
Tender For corrigendum : supply of auto electrical spares of hemms d d - toggle switch, part no. 81004329 , battery terminal positive, part no. cet0401175 , battery negative terminal, part no. cet0402160 , halogen h3 bulb 24v,70w, part no. lhb303 , lamp gp head 24 volt high biam, part no. 1570305 , battery relay, part no. 808820000 , spot fan, part no. 935cc01034 , horn, part no. 4449757 , h t cable 4401045, part no. 440045 , wire elec, cu,4mm , auto wire 5mm 28by.012, part no. aw5mm , wire elec, cu,6mm , battery lux 24v, part no. hd1383a , tape insltn, pvc,3 by 4in,10m , vrnsh oil, insltg , cnctr lug, 10mm2, cu , emegency steering relay, part no. 953eg87362 , dump switch, part no. 953eg87387 , reverse signal switch, part no. 81016169 , engine shut off switch, part no. 953eg83311 , back up alarm, part no. 935eg11669 , key switch, part no. cek0120000 , wiper motor switch, part no. 953eg83385 , hour meter, part no. 935eg11417 , circuit breaker 5a, part no. 985eg81883 , circuit breaker 10a, part no. 958eg81891 , circuit breaker 20a, part no. 958eg81912 ) /bid number : gem/2026/b/7431901 * /dated: 10-04-2026 & & / bid document 1 / 34
Tender For corrigendum : supply of terminal insulator/bushing for 6.6 kv 1100kw and 400 kw btrdt motor , terminal enclosure for 6.6 kv 1100kw and 400 kw btrdt motor , grommet insulator for 6.6 kv 1100kw and 400 kw btrdt motor , bakelite disc for 6.6 kv 1100kw and 400 kw btrdt motor
Tender For survey, investigation, design, supply, erection, testing and commissioning of required number of vertical turbine pumps coupled to ht motor for providing irrigation facility to suffering atchkat 2847 ha. of lateral no.27 to 32 of dy.no.6 of shahapur branch canal from karnal nala under karnal lis in shorapur taluk yadagir district viz., construction of diversion weir, intake forebay, jackwell cum pump house, manifold along with electrical panel, soft starter, capacitor, 11 kv power transformers, ht bus bar / cabling, 11/6.6 kv sub-station, power line and 11 kv terminal bay, ms rising main, valves and construction of delivery chamber, erm to lateral 27 & 31 of d-6 (selected reach) supply of spare, accessories and tools including operation & maintenance of the entire system for five years from the date of successful commissioning of karnal lift irrigation scheme on turnkey basis.