Tender For supply of supply, installation, testing and commissioning control panel 2 loops,sitc control panel 4 loops,sitc of network module the module shall connect panels,sitc of active repeater panel to be integrated with fire alarm,sitc of addressable ip67 rated multi- heat sensor,sitc of analogue addressable photo thermal smoke detector,sitc of analogue addressable photo thermal smoke detector,sitcof addressable multi sensor with co detection,sitcc of response indicator on surface or recessed,sitc of short circuit isolator module base with all mounting,sitc of analogue addressable dual action,sitc of addressable horn with a maximum output of up to 100 db a,sitc of analogue addressable supervised monitor module,sitc of analogue addressable supervised control module,supplying and laying through walls,complete earthing electrode and excavation etc,earth continuity conductor,false ceiling board and cross tee,butterfly valves (v2) as per is 13095,butterfly valves (v2) as per is 13095
Tender For supply of supply, installation, testing and commissioning control panel 2 loops,sitc control panel 4 loops,sitc of network module the module shall connect panels,sitc of active repeater panel to be integrated with fire alarm,sitc of addressable ip67 rated multi- heat sensor,sitc of analogue addressable photo thermal smoke detector,sitc of analogue addressable photo thermal smoke detector,sitcof addressable multi sensor with co detection,sitcc of response indicator on surface or recessed,sitc of short circuit isolator module base with all mounting,sitc of analogue addressable dual action,sitc of addressable horn with a maximum output of up to 100 db a,sitc of analogue addressable supervised monitor module,sitc of analogue addressable supervised control module,supplying and laying through walls,complete earthing electrode and excavation etc,earth continuity conductor,false ceiling board and cross tee,butterfly valves (v2) as per is 13095,butterfly valves (v2) as per is 13095
Tender For supply of detector removal tool as per atc , loop card micro module as per atc , serial esser net interface modules as per atc , network card essernet series 2 nw card 64 k as per atc , main fire alarm control panels cpu card for facp as per atc , iq8 repeater panel as per atc , heat detector as per atc , otg multisensor fire detector co iq8quad with isolator as per atc , o2t multisensor fire detector iq8quad with isolator as per atc , otblue multisensor fire detector iq8quad with isolator as per atc , optical smoke detector iq8quad with isolator as per atc , controller for lhdc as per atc , esserbus transponder rzt 24 v as per atc , flame detectors as per atc , usb cable ab and serial connecting cable as per atc
Tender For corrigendum : supply of loop card for fire alarm control panel , monitor module addressable type monitor module. , control relay module addressable control relay module. , optical cum thermal detector intelligent addressable multi criteria optical cum thermal detector wit , optical cum chemical detector intelligent addressable type, maintenance easy optical cum chemical de , response indicator , break glass type manual call point intelligent addressable break glass type manual call point. , sounder or hooter addressable type loop powered /external powered sounder or hooter with multiple to
Tender For supply of plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , canvas fire hose with male and female coupling 63mm dia x 15 mtr long , ms fire hook with babu standard length , ms fire double hose box of size 800x600x250mm , ms fire hose reel drums 3 or 4 inch for 30 mtr hose , ms fire hose reel drums 1 inch for 30 mtr hose , ms fire hose reel heavy duty 20mm dia x 30 mtr long for hose , fire hydrant landing valves gun metal single outlet 63 x80 mm dia flanged pipes , fire hydrant landing valves gun metal double outlet 63x80 mm dia flanged pipes , non return valve 150 mm dia pn 1.6 , non return valve 100 mm dia pn 1.6 , butterfly valve 150 mm dia , butterfly valve 100 mm dia , foot valve 150 mm dia , foot valve 100 mm dia , fire alarm control panel conventional type 8 zone , fire alarm control panel conventional type 12 zone , fire alarm control panel addressable type up to 99 loop , manual call point , electronic hooter , heat detector automatic reset type , pvc insulation tapes size width 20 mm length 10 mtr , hydrant key as per isi * /bid number : gem/2026/b/7704220 + /dated: 24-06-2026 ' ' / bid document 1 / 25
Tender For supply of fire alarm panel for mubarikpur , addressable smoke detector for mubarikpur , addressable heat detector for mubarikpur , outdoor mcp for mubarikpur , addressable indoor hooter for mubarikpur , cable 1 and half sqmm 2 core frls armoured for mubarikpur , installation and commissioning for mubarikpur , repeater panel for bharatpur , installation and commissioning of repeater panel for bharatpur , fire alarm panel for mahmudpur majra , addressable smoke detector for mahmudpur majra , addressable heat detector for mahmudpur majra , outdoor mcp for mahmudpur majra , addressable indoor hooter for mahmudpur majra , cable 1 and half sqmm 2 core frls armoured for mahmudpur majra , installation and commissioning for mahmudpur majra , fire alarm panel for usrai and bahlolpur , addressable smoke detector for usrai and bahlolpur , addressable heat detector for usrai and bahlolpur , outdoor mcp for usrai and bahlolpur , addressable indoor hooter for usrai and bahlolpur , cable 1 and half sqmm 2 core frls armoured for usrai and bahlolpur , installation and commissioning for usrai and bahlolpur
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For supply of intelligent analog addressable smoke detector complete with mounting base complete as required , addressable manual call point complete as required , addressable fire control module relay module as required , one time rectification and restoration of the fire alarm system , micro processor based intelligent addressable main fire alarm panel , one time replacement and rectification of the fire alarm system , supply laying and termination of 2cx1 5 sq mm frls pvc insulated copper conductor , supply and installation of loop powered base addressable sounders complete with all fixing materials complete as required , one time rectification of the fire alarm system 2 loop which is having 153 nos of detectors and 10 manual call points