Tender For corrigendum : supply of firedetection alarm system spares d d - telescopic 4 section access pole , fire smoke and heat detector removal tool of adjustable diameter , firedetection aerosol dispenser suitable for testing detectors , non flammable, hfc free smoke aerosol smoke detector tester , glass elements for replacing broken glasses in manual call point
Tender For supply of fire alarm and detectionsystem e e - 2 loop addressable fire panel , addressable photo electric smoke sensor with base , addressable manual call point , addressable hooter cum strobe , input module , addressable heat detector
Tender For nsac and substation fss - 1. fire alarm control panel conventional, conventional, 2-zone supply, installation, testing <(>&<)> commissioning complete with visual indications for alarm, fault, short/ open circuit, zone mimic board etc. 2-zone sector panel / conventional panel as per is standards (make and model: ravel) conventional, 2-zone supply, installation, testing <(>&<)> commissioning complete with visual indications for alarm, fault, short/ open circuit, zone mimic board etc. 2-zone sector panel / conventional panel as per is standards (make and model: ravel) 2. supply & fixing of optical smoke with mounting base, led (make and model: (apollo, siemens, honeywell, simplex, notifier) detector base mounting base for smoke detector (make and model: ravel) detector (photoelectric type) complete with base, led indication, suitable for ceiling mounting, conforming to is 2189 - (make and model: ravel) 3. supply & fixing of manual call point (make and model: ravel) (mcp), break glass type / resettable type, complete with mounting box, suitable for fire alarm system, conforming to is 2189- (make and model: ravel) 4. supply & fixing of hooter cum strobe, (make and model: ravel) electronic hooter with flashing strobe light, suitable for indoor use, conforming to is 2189 - (make and model: ravel) 5. supply & laying armoured cable 21.5 sqmm (frls/swa) 21.5 sqmm (frls/swa) - make reputed 6. supply, installation, testing & electrical, interconnection, loop termination, functional tests commissioning of online 1kva ups with minimum 30 minutes backup for fire alarm panel - make apc / vertiv / eaton or equivalent 7. testing, commissioning, as-built drawings, test certificates, o<(>&<)>m manuals documentation <(>&<)> drawings as-built drawings, test certificates, o<(>&<)>m manuals
Tender For supply, installation & commissioning of various sub-assemblies to convert rake formation type of fsds of make m/s sanrok to stand alone type automatic smoke/firedetectionsystem as per rdso specification no. rdso/2008/cg-04. rev.6. (provision of interface of fsds with brake valve). scope of supply and commissioning is enclosed at annexure-1. [ warranty period: 30 months after the date of delivery ]
Tender For supply of isi mark gi pipe all fittings 25 mm dia , lowering laying and jointing gi pipe 25 mm dia , isi mark gi pipe all fittings 40 mm dia , lowering laying and jointing gi pipe 40 mm dia , isi mark gi pipe all fittings 50 mm dia , lowering laying and jointing gi pipe 50 mm dia , isi mark gi pipe all fittings 80 mm dia , lowering laying and jointing gi pipe 80 mm dia , isi mark gi pipe all fittings 100 mm dia , lowering laying and jointing gi pipe 100 mm dia , isi mark gi pipe all fittings 150 mm dia , lowering laying and jointing gi pipe 150 mm dia , two coats of enamel paint over and one coats of red oxide primer , brass quartzoid sprinklers 57 degree , drain assembly 25 mm dia , ss flexidrop 1000 mm long , ss rosset plate , hydrant valve type a , short branch pipe , hose reels drum , hose boxes single door , rrl hose pipe , 4 way fire brigade inlet , wrapping 4mm thick protection coating 150mm , wrapping 4mm thick protection coating 100mm , ms steel for supports , core cutting 150 mm , core cutting 100 mm , core cutting 80 mm , excavation for pipe line , rcc pipe 300 mm dia , lowering laying and jointing rcc pipe 300 mm dia , refilling of trench , diesel driven pump , electric driven main fire pump , jockey pump , fire pump control panel , pressure vessel , sluise valve 150 mm dia , sluise valve 80 mm dia , sitc butterfly valve ci body 150 mm dia , sitc butterfly valve ci body 100 mm dia , sitc butterfly valve ci body 80 mm dia , double flanged metal bellows 150 mm dia , double flanged metal bellows 80 mm dia , y type stainer or foot valve 150 mm dia , y type stainer or foot valve 80 mm dia , sitc nrv non return valve 150 mm dia , sitc nrv non return valve 80 mm dia , air release valve , cable end termination and connection 1 point 5 sqmm , cable end termination and connection 4 sqmm , cable end termination and connection 16 sqmm , cable tray system , pressure gauge , pressure switches , ms steel for supports , addressable 2 loop main panel , photoelectric smoke detector , manual call point , addressable sounder , computer based software , isolator base , 1 point 5 sqmm 2 core red cable armd , beam type smoke detector , 12v 7ah batteries for panel , abc powder type fire extinguisher 6kg , abc powder type fire extinguisher 5kg , co2 type fire extinguisher 4. point 5 kg , 4 kg fk 5112 extinguishing agent , firedetection tube , end line adaptor for firedetection tube , end of line plug , pressure switch , tube t connector push type , mcu 1 master control unit , installation charges , emergency exit board , fire hydrant board , fire alarm call point board , abc extinguisher board , co2 extinguisher board , pass or race board , assembly point board , left side man running with arrow tape board , anti skid tape , evacuation plan , fire buckets , emergency light with exit sign , maintenance of equipment 1st year , maintenance of equipment 2nd year , maintenance of equipment 3rd year , legal and liasoning charges , rcc water tank 100000 ltr , rcc frame structure for pump , cc grade m25 , mass cement concrete in 148 proportion , tmt fe500 steel , pvc pipe 63 mm dia , pvc pipe 75 mm dia , lowering laying and jointing pvc pipe 63 mm dia , lowering laying and jointing pvc pipe 75 mm dia