Get complete information related to latest Lcd Television Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lcd Television Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lcd Television Scrap Tenders.
Tender For corrigendum : tn-23018 supply of fire fighting equipment and spares, kstps, kota. - supply of fire-fighting equipments and spares for kstps, kota, discharge tube for dcp 5kg. fire extinguisher (18" ft. hose length) cartridge type, discharge tube for dcp 10kg. fire extinguisher (24" ft. hose length) cartridge type, hose with horn for co2 extinguisher 22.5 kg (5 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., hose with horn for co2 extinguisher 4.5 kg (1 mtr. hose length) hose is connected with end connection on both side. co2 gas is discharged through this hose. one end is connected to discharge horn., discharge tube for 25 kg dcp wire braided hose (3 meter length), supply of ss304 seat valve assembly with rubber washer for 63mm hydrant valve , as base plate sheet (metallic) with base plate check nut, with neoprene rubber wash- er for spindle., supply of c.i is: 210 hand wheel for 63mm hydrant valve, supply of q.b detector 1/2" size 79deg it operates as a valve by allowing the flow of water contained in a fire qbd system when the heat sensitive element (glass bulb or fusible link) is operated., supply of ss304 63mm female outlet for 63mm hydrant valve, supply of ss304 63mm bonnet for 63mm hydrant valve, supply of ss304 63mm spindle for 63mm hydrant valve, discharge tube with nozzle for foam 9 ltr. fire extinguisher (1.5 mtr. hose length), insulated hand gloves with working voltage of 17000 volts and proof voltage 25000 volts as per is 4770, gumboot with steel toe cap moulded pvc to protect against oil acid and alkalie re- sistance confirming to is 15298, 63mm rubber washer for female outlet of hydrant valve, supply of s.s-304 63mm single headed fire hydrant valve as per is: 5290, vtype-a, isi marked. having pvc male blank cap with chain., ceramic wool fire blanket white density: 128 kg/m3, size : 610x7100 mm; thick- ness =25 mm. weight : 3130 gsm thisckness test metod : astm d 1777& weight test metod : astm d 3776 tensile strength in kgs (1 x4 ) = 10 to 16 psi, potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s potassium based aerosol ; first responder produces an exceptionally effective, ultra fine aerosol that provides extremely fast knockdown and rapid sup-pression of fires. aerosol mass 0.5 kg. length 142.9mm with actuator 174.6 mm.;diameter 80.98 mm.; delay time 3.5 seconds &discharge time 20 sec.operating temp. -29 c to +60 c; classification code : 1.4s, high velocity spray nozzles 80 , nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 90 nicalchorme plated, ul listed, 3/4 bspt, high velocity spray nozzles 120 nicalchorme plated, ul listed, 3/4 bspt, hose reel with horn for co2 length : 15 mtr. hose reel made of ms having unique ball valve shut of devise with breaded hose & nozzle. drum red/ hose pipe black.drum length 15 mtr. , hose pipe length and diaas per requirement. test pressure 10 kg./cm.sq of hose pipe. control nozzle at the end is attached to control flow & direction., discharge tube with nozzle for foam 45 ltr. fire extinguisher ( 4.5 mtr. hose lenght)
Tender For custom bid for services - yearly routine of fm 200 system-e-065: - yearly routines are falling due on fm-200 system of this unit. |routines to be carried out as per maintenance schedule and system to be proved for satisfactory operation. following jobs to be carried out as part of the routines: () after removal of solenoid valve from fm-200 cylinder head of the system, the following checks need to be carried out: electric remote cabinet opening |from remote and pneumatic release cabinets. () systems check- checks each electrical manual release unit for operation. (ii) check fire alarm and evacuation alarm lights and sounds. (iv) check that all ac are shut down or dampers are closed, if any. (v) check that all pneumatic actuator operates after pre-set time delay. (vii) check operation of discharge pressure switch and check indicator lamp. (viii) reset all pneumatic actuator, electrical actuators, discharge pressure switch and fire alarm system. (ix) pipe work/ nozzle to ensure that they are free from debris. (x) check dust caps are fitted. (xi) containers - check containers are safe mechanical damage, corrosion or unauthorized interference. (xi) check containers brackets are fitted and all bolts tightened. (xii) chek pneumatic actuation tubing is firmly fixed and all connections are |tight..