Web Analytics Made Easy - StatCounter

Load Tap Changer Tenders

Get complete information related to latest Load Tap Changer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Load Tap Changer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Load Tap Changer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :38470814 Due date: 06 Jan, 202506 Jan, 2025 10.16 Crore
Tender For supply of 1 no. 80 mva, 400/11.5/11.5 kv, 3 phase, 3 winding, 50 hz, onan/onaf/ofaf cooled station transformer (without cooler bank) with on load tap changer along ngrs and filled with oil for bellary thermal power station

CTN :38424088 Due date: 18 Dec, 202418 Dec, 2024 7.87 Crore
Tender For 10 mva, 33/11 kv, outdoor type, 3-phase, two winding, copper wound, oil immersed power transformer(s) with on load tap changer (oltc), remote tap change control (rtcc) panel with scada compatible, complete with all fittings, accessories, associated e

CTN :38424105 Due date: 18 Dec, 202418 Dec, 2024 4.62 Crore
Tender For 6.3 mva, 33/11 kv, outdoor type, 3-phase, two winding, copper wound, oil immersed power transformer(s) with on load tap changer (oltc), remote tap change control (rtcc) panel with scada compatible, complete with all fittings, accessories, associated

CTN :38424152 Due date: 18 Dec, 202418 Dec, 2024 68.33 Lacs
Tender For 3.15 mva, 33/11 kv, outdoor type, 3-phase, two winding, copper wound, oil immersed power transformer(s) with on load tap changer (oltc), remote tap change control (rtcc) panel with scada compatible, complete with all fittings, accessories, associated

CTN :38442298 Due date: 25 Dec, 202425 Dec, 2024 NA
Tender For supply, erection, testing & commissioning of 500 kva outdoor, plinth mounted, oil immersed, non-sealed type (transformer tank body and cover are bolted) distribution transformer, 500 kva rating, 11kv/415v, 3-phase, 50 hz, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled, off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, with all standard fittings as per clause 20.1 of is 1180 (part 1) and oil temperature indicator & winding temperature indicators, drain-cum- sampling valve (3/4? nominal size thread,is:554) of steel with plug, energy efficiency level- 3 & above, conforming to is 1180 (part 1): 2014 with amendment nos. 1,2,3 & 4. following has to be submitted along with supply of material:- (i) type test report as per is: 1180 (part 1) of transformer having same rating, make (& model if any) and design from nabl accredited lab. (ii) routine test certificates as per is: 1180 (part 1). (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:1180(part 1) accepted make : andrew yule/aeg/crompton greaves/kirloskar electric co./abb /siemens/ schneider electric or equivalent.
 Loading, Please wait...

Connect us via What's Up