Tender For corrigendum : supply of ac ammeter 0-250a with external ct250-5a, 3. 5 digit, aux 240v actype smp35s ae make , output ac ammeter 0200a, 96 sq mm 240 deg scale acc class 1. 5 with 200-5 ct ratio, type mlc96 ae make , output ac ammeter 0-50a with external input 1a-5a programmable, 3. 5 digit, aux 240v ac, acc 1 type digital ac ammeter 50-5 um49 ae make , output frequency meter, display bright red led 4digit 9999counts, to read 45-60hz, input 240ac, aux supply 240v, type no fdm38as ae make , output frequency meter, 240v ac 96 sqmm to read 45-55 hz ae make , output power factor digital meter display red led 4digit to indicate pf input voltage 240v ac, input current 5a,50hz type dpf11 ae make , digital panel meter ac ammeter 0-250a, range 0-250a ac, operating current ac with external ct 5a, aux supply 240v ac, 50hz, maximum indication 1999, ae make , digital panel meter ac ammeter 0-25a, model no a1 led-7 segment digital ,operating current ac with external ct 5a, aux. supply 240v ac, 50hz, maximum indication 1999, ae make , digital panel meter ac ammeter 0-400a, model no a1 led-7 segment digital type,operating current ac with internal ct 5a, aux supply 240v ac50hz, maximum indication 1999 model-um49 4005a accur 1ae make , digital panel meter ac voltmeter 0500v, model no um-49 led-7 segment digital type ,operating voltage 650v ac, input 0-500v ac, range2-120 ae make , digital panel meter dc ammeter 0-600a, model no a1 led-7 segment digital type,operating current dc with external shunt 75mv, aux supply 240v ac, 50hz, ae make , digital panel meter dc ammeter 0-250a, model no a1 led-7 segment digital type ,operating current dc with external shunt 75mv, aux. supply 240v ac, 50hz, ae make , digital panel meter dc ammeter 0-50v, model no a1 led7 segment digital type ,operating voltage 700v dc, aux supply 240v ac, 50hz, ae make , digital panel meter dc voltmeter 0-300v, model no a1 led-7 segment digital type,operating voltage 700v dc, aux supply 240v ac, ae make , digital panel meter dc voltmeter 0-400v, model no. a1 led- 7 segment digital type , operating voltage 700v dc aux supply 240v ac50hz, maximum indication 1999 accur 1ae make , ac voltmeter 0-500v, 96 sqmm 240 deg scale acc class 1. 5 type mlc96 ae make , dc ammeter 500-01500a, with external shunt 75mv fsd, 96 sqmm 240 deg scale acc class 1. 5 type mlc96 ae make , dc ammeter 0300a, 75mv fsd, 96 sqmm 240 deg scale acc class 1. 0, type-sq96 ae make , ac ammeter 0-300a, 96 sq mm. 240 deg scale acc class 1. 0 with 300-5 ct ratio,type mlc96 ae make , ac ammeter 0-200a, 96 sq mm, 240 deg scale acclass 1. 0 with 200-5 ct ratio, type sq96 ae make , ac ammeter, 0-50a, acc class 1, type no si96-smi 96 suitable for 5a ct ae make , ac ammeter 0-300a, 96 sqmm 240 deg scale acc class 1. 0 with 300-5 ct ratio, type mlc96 ae make , ac voltmeter 0-500v, 96 sqmm 240 deg scale acc class 1. 0, type sq96 ae make , ac voltmeter 0-300v, 96sqmm, acc class 1, 240 deflection, si96-smi 96 ae make , ac voltmeter 0-500v, 96 sqmm 240 deg scale accclass 1. 0 type mlc96 ae make , voltage transducer, 0-300v dc, aux supply 220v dc, dual output 4-20ma dc, capable of burden 600ohms, ae make , dc voltage transducer 0-60v, dual output 4-20ma, input 48vdc , capable of burden 600ohms ae make , protection ct kab 1330 500-0. 2a ae make , 150a-0- -15a dc analogue meter with150a shunt, 75mv output size - 96sq mm, 240 scale, class1. 5 with ,ae make //bid details2 / 53
Tender For purchase of measuring instrument ammeter(-/1a) single phase ,ammeter(-/1a) three phase ,ammeter(-/5a) three phase ,voltmeter(-/110v) single phase ,voltmeter(-/110v) three phase ,power factor meter(-/5a) single phase ,power factor meter(-/5a) three phase ,dc digital voltmeter ,multifunction meter(-/1a) ,multifunction meter(-/5a)
Tender For corrigendum : provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(a
Tender For tender for supply of make- ird mechanalysis limited , ird544m - vibration sensor , inductive velocity , top exit , mil 2-pin connector , 42.52mv/mm/s , 10 hz - 1 khz sku - m97120 , make- ird mechanalysis limited , stud for vibration sensor item no 1 , mounting/grub screws , 1/4 inch-28unf male , m6 x 1 male sku - stud-m6 provides connection between vibration sensor and mounting pad , m/s ird mechanalysis limited , vibration sensor mounting pad mild steel blackodized for ird544m (60x60x16 mm) with m6 thread for item no 1 tapped sku - ms-pad-ird544m , make- m/s ird mechanalysis limited , vibration sensor cable assembly for item no 1 , signal cable teflon 3.5mm dia , ss conduit 5mm id , 15 meter length straight , 2 pin ms , shielded , spade lugs at free end sku - m601015spade lugs at free end carry following colour code- red core- signal live , black core- signal ground , green core- signal shield , make- ird mechanalysis limited , eddy current pickup set comprising of probe , driver and connecting cable for 9 meter system. constituents. , make- m/s ird mechanalysis limited ird8800 rack , 8 position , 5u sku - m88008 this is the bin and will accomodate ird8800 cards , make- ird mechanalysis limited ird8800 (8800) , m88250 (88250) casing vibration module , 2ch velometer input (mv /mm/sec) and 1ch key phasor input , api standard 670 compliant sku - m88250-dc ird8800 series module m88250 can work with all types of velocity output vibration sensors that provide mv/mm/sec output - like ird531 (4 mv/mm/sec) and ird544m (42.52 mv/mm /sec) , make- m/s ird mechanalysis limited , ird8800 (8800) , m88900 (88900) - speed module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88900-dc , input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcp-ip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , ird8800 (8800) , m88600 (88600) - eccentricity module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88600-dc input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcpip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , 35 mm din rail mount industrial grade power supply , 480 w , product- rps480 , 24 v dc output , dimension- 60 x 154 x 158.55 mm (w x h x d) , weight- 1050 gms , sku - rps480-24-ce supports 90 - 264 vac / 127 - 370 vdc power factor more than 0.95 full load over entire input range protection against short circuit , overload , overvoltage & over temperature cooling by free air convection ul 508 approved (e522848) efficiencies up to 93 % dc ok relay contact , make- ird mechanalysis limited , cabinet 1500 x 600 x 600 in mm , ip32 sku - cabinet-1500-600-600-ip32 , installation commissioning and calibration check of all supply sensor with unit at site