Tender For corrigendum : supply of ht trivector meters of class 0.5s with dlms protocol - supply of three phase, 4 wire, a.c. static ht-trivector energy meter of accuracy class 0.5s with dlms protocol against tn-2944.
Tender For corrigendum : lttvm - supply of three phase, 4 wire, a.c. static lt-trivector energy meter of accuracy class 0.5s with dlms protocol against tn-2945.
Tender For supply and installation of electrical consumables for day-to- day maintenance for a period of 02 years at goa college of engineering. - supply, installation, testing and commissioning of 18 /20 watt led tubelight luminaire complete with all accessories etc. as required of make: bajaj cat no. bclab 20wledp/make: crompton cat no. ccs- 100-20- 65-hl2-dp-nwh;m ake jaquar cat no. lglz01020xw or equvivalent in wipro/philli ps/great white etc as per instructions of the engineer incharge., supply of 9w led bulb , of make panasonic, ( cat no:pbum36093) or equivalent in bajaj/havell s/panasonic/phi lips /jaquar/le gero/orient/bio con. complete as required. (equivalent to be approved by engineer in-charge ), supply and fixing of 2.5 microfarad fan capacitor of reputed brand complete as required., unarmoured pvc /xlpe1100 v cable 2 core 10 sq.mm aluminium, supplying and fixing brass batten/ angle holder including connections etc as required., re-wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in the existing surface/ recessed steel pvc conduit or casing caping including dismantling as required.; group b, supplying and drawing following sizes of frls pvc insulated copper conductor single core cable in the existing surface/ recessed steel pvc conduit or casing caping including dismantling removing old wires as required.;(11) 2 x 2.5 sq.mm, supplying and fixing following size modular pvc box alongwith modular base and cover plate for modulator switches in recess etc. as required;(i) 3 module cat b, supplying and fixing following size modular pvc box alongwith modular base and cover plate for modulator switches in recess etc. as required;(k) 6 module cat b, wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm fr pvc insulated copper conductor single core cable in pvc casing caping with modular switch modular plates suitable size modular surface box of specified category and earthing the point with 1.5 sq.mm fr pvc insulated copper conductor single core cable etc. as required.;(b) group b -- with cat b modular accessories, supply and erecting of 56 inch (1400mm sweep) ceiling fan double ball bearing type complete with all accessories .; cat b, supplying and fixing 6 a to 32 a c series mcb suitable for lighting and other loads of following poles in the existing mcb db complete with connections testing and commissioning etc as required.;(f) sp cat b, supplying and fixing 40 a c series mcb suitable for lighting and other loads of following poles in the existing mcb db complete with connections testing and commissioning etc as required.;(f) sp cat b, supplying and fixing 63 a c series mcb suitable for lighting and other loads of following poles in the existing mcb db complete with connections testing and commissioning etc as required.;(j) tpn cat b, wiring for circuit/ submain wiring alongwith earth wire with the following sizes of fr pvc insulated copper conductor single core cable in the independent pvc casing capping of appropriate size as required.;(b) 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earthwire (20mm casing ), erection of wall bracket/ ceiling fittings of all sizes and shapes containing upto two gls lamps per fitting complete with all accessories including connections etc as required., din hrc fuses size size 0 200a, supply installation testing and commissioning of electronic type three phase energy meter (kwh) 4 wire isi marked in polycarbonate or sgheet steel body ( base mounting type) with counter display /lcd display with elt in class 1.0 50 hz 240 v. ac duly tested by mrt along with test certificates complete as required of following capacity of make l & t only.;(c) 50 to 100 a, providing and fixing following capacity tpn disconnector fuse switch unit in ss enclosure without hrc fuses including drilling holes in cubicle panel making co
Tender For manual and spot billing of 8500 consumers per month by loading of sbm, meter reading, preparation of energy bills, delivery of energy bills to the consumers duly acknowledged, down loading of sbm, under electrical sub-division (rural), hpsebl, baroh
Tender For manual and spot billing of 12500 consumers per month by loading of sbm, meter reading, preparation of energy bills, delivery of energy bills to the consumers duly acknowledged, down loading of sbm, under electrical sub-division (urban), hpsebl, nagr
Tender For auction sale of acsr conductor scrap,ms scrap-i 2 pin/4pin/ dp set/ tc set/clamps/ 2/3 legged tower etc.,,rcc pole skeleton,ms scrap-ii,ms scrap-iii scrap energy meter,empty oil barrel,empty wooden real
Tender For drilling of bore well, electric poles with lighting arrangements, energy meter connection and power supply connection work at sagar colony park in kadapa municipal corporation