Tender For (92361) improvement of water supply transmission main with tapping connection using hydraulic isolation structure (manifold) at sec. 13 esr koparkhairne in nmmc area.
Tender For supply and delivery of 2 nos light commericial vehicle at rr park in cuddalore zone, villupuram district - bs-vi norms. driver cabin, power steering wheel base of 2590 mm turbo charged intercooled with lean nox trap (lnt) a hopper tipper dumper is a truck designed for carrying material, which may be garbage, construction material, mining minerals and any other loose material. the truck is fitted with specially designed hydraulic tipping mechanism driven by pto or power pack, which enables the dumper (rear portion expect the driver cage) to move up and down for unloading of the material. it is the safest way to quickly transport loose materials from one site to another., tipper body: construction of 4 wheeler mini tipper with tipping arrangements having body in with minimum pay load capacity of 3.0 cum capacity with box tipper bs6 chassis.dimension: tipper body equipment should have a sub frame minimum of 75x 40x3 mm ms tube and long runner minimum of 75x 40x3 mm ismc, body structure 2.0 mm thick m.s. sheet with body side 2mm ms sheet, body size 2.5 x 1.6 x 0.75 mtr in size. operating in high pressure hydraulic system with high quality power pack & telescopic cylinder. back door butterfly type. the section of the tipper body should be machine press and folded for light weight and heavy strength should be neat, sturdy and good aesthetic look. painting & letter writing as per panchayat requirements. the rate including gst
Tender For supply of installation commissioning and testing of 15 kva off grid solar power plant - solar module , modulemountingstructure , pcu , copper wire , ac distribution board , dc distribution board , battery bank , earthing kit , lightning arrestor and overvoltage protection , structural hardware , battery rack
Tender For amc of fire alarm and fire fighting system at iaa vasant kunj new delhi for two years - amc of fire alarm and pa system.fire alarm technician skilled- 3 nos., 1 no. in each shift round the clock. helper un-skilled- 1 no. in general shift. , amc of fire hydrant and wet riser system. , comprehensive servicing and overhauling of fire engine. , oem service engineer or oem trained service engineers visits , repairing of cps-24e power supply card , supply of cps-24e power supply card , supply of frm module mcp of approved makes as per site requirment. , supply of mcp glass of approved makes as per site requirment. , supply of pressure switch of approved makes as per site requirment. , refilling of fire extinguishers abc type 9.0 kg. , refilling of fire extinguishers co2 type 4.5kg. , hydraulic testing of fire extinguisher abc type 9.0 kg. , hydraulic testing of fire extinguisher co2 type 4.5kg. , finding leakage of underground pipe in sand , finding leakage of underground pipe in concrete or cemented or tiled or man made structure area , to detect c class type pipe or existing fire fighting pipe of different dimentions leakage. , to repairing or rectify leakage in fire pipe line of under ground including wrapping and coating. , to repairing or rectify leakage in fire pipe line of above ground including primering and painting. , painting of 25mm existing fire pipe lines with two coats. , painting of 50mm existing fire pipe lines with two coats. , painting of 80mm existing fire pipe lines with two coats. , painting of 100mm existing fire pipe lines with two coats. , painting of 150mm existing fire pipe lines with two coats. , painting of 200mm existing fire pipe lines with two coats. , site visit of fire technician or fire engineer during the inspection by fire officers and other civic authority for fire noc. , supply of 4 sq.mm 4 core copper conductor un-armoured lt power cable. , supply of 6 sq.mm 4 core copper conductor unarmoured lt power cable. , dsr electrical 2022 - rs. 5,00,000
Tender For installation , testing , commissioning and supply of lcd solar power plant (roof top) for ong rid system, single phase 17 kw power with output voltage 240 v complete with solar spv array , modulemountingstructure , power conditioning unit (pcu) consisting of maximum power point tracker (mppt) , inv ertor (200 v-800 v. max output current-27a)and controls & protections, inter connect cables and switches. switching device-igbt, pure sine wave output,ip-65, electric cable for input(pv module to inverter)- 1 x4 sq mm copper cable , length-25 mtr electric cable for output (inverter to net meter)- 3.5x10 sqmm copper cab le, length-30 mtr , suitable netmeter, lighting arrester ,earthing ,danger bord. pv module (as per is:14286) rating -250-1000 wp, no. of pv module-51 nos . total load of roof-60 kg per sqm(max). minimum clearance of structure from roof level-300 mm. suitable to withstand wind pressure fo 180 km/hr. area required for ins tallation- 180 sq.m. installation & testing of the complete system including civil work , designing cabling wo rk with suitable clamps & fasteners etc. make- tata power solar, vikram solar, spj solar or similar. warrant y of solar power plant -as per ministry of new & renewable energy (mnre) [ warranty period: 30 months after the date of delivery ]
Tender For providing of customized amc/cmc for pre-owned products - 140 t bd crane - 1) annual maintenance will be signed by railways and the tenderer who taking responsibility of maintenance of the 140 t gottwald bd crane. annual maintenance contract means, the contractor will undertake the maintenance activity of the 140 t gottwald bd cranes, as per the terms and conditions decided. 2) hydraulic (rexroth) for both the undercarriage and the super structure. 3) pneumatics (sab wabco and knorr) for both the undercarriage and the super structure. 4) gear drives (lohmann) for the complete crane 5) bearings (fag, skf, elges) complete check/ inspection. 6) slewing ring (rothe erde and rks) complete check/ inspection 7) auxiliary engine- complete check/ inspection/repair 8) during amc period you would cover all the systems of the crane mentioned above and ensure that each system is working optimally and that the systems are interfacing with each other to provide the desired load capability. 9) while conducting the inspections during the amc visits, your engineers would also be able to indicate the requirement of the spares by identifying parts that would need replacement together with your staff. in doing so, we could establish a system for predicting which parts would be required and when, thus allowing for proper planning for procurement. 10) labour charges for rectifying defects/failure will be borne by the contractor