Tender For electrical equipment - electrical equipments, circuit breaker study panel: - 3 pole miniature circuit breaker 16,20,30a fixed on the hylam sheet- one lamp load connected with the mcb- one 230v indicator lamp will be provided on the main board- mimic diagram printed on the hylam sheet., electrical connector switch wiring study panel:- 5a,16a switches are mounted on the hylam sheet- wiring for the switches connected with the lamp- easy wiring teaching panel with connectors.- electrical switch mimic diagram on the front panel, watt hour meter study panel:- watt hour meter (230v 20a ac) mounted on the hylam sheet with proper fuse production.- mcb fitted on the front panel- lamp load mounted on the front panel- electrical diagram printed on the panel- all the connectors are terminated for easy wiring.230 v 20 amps ac analog watt hour meter, miniature circuit transformer study panel:- differed type of step-down transformer 5v,9v, and 12v,- one number of step-up transformer also fitted on the panel.- proper banana connector for primary and secondary side- ac lamp load for testing the transformer output., different types of ac inductor study panel:- different type of inductor mounted on the panel- all inductors are hf ac inductors.- the inductors parameters are printed on the panel., hand drill (or screw gun) to mount panel and osb - drill machine 4500 rpm | hammer drill kit | power tools & drill machines | 400w power rating drill machine | efficient pistol grip drill (10 mm chuck size), voltage:230 v , weight:1.3 kg, frequency: 50 hzpower: 400 w, miniature circuit transformer, 230 v 20 amps ac analog watt hour meter, basic toolbox - 6 piece screw driver set of 0 & 1pt phillips or any equivalent make 1.4, 2,2.4, 3 mm slotted, hf ac based inductors, nema 4x pvc electrical cabinet., analog ammeter (analog ammeter, direct type, 1 , 72x72mm) measuring current range 10 to 100a, vfd control panel (750 mm (l), 750 mm (d), 1600+150 mm (h).) drive mains supply: single phase, 230v ac 10%, 50hz input voltage: single phase, 230v ac 10% output voltage: three phases output frequency range: 0 to 60hz (default range) with resolution of 0.01hzthree phase induction motor type:squirrel cage rating: 0.5hp voltage rating: 415v ac speed: 1440 rpm 5% insulation: class b/f , nema34 planetary geared stepper motor 750kgcm, manual ranging digital multimeter 750v 20a with temperature probe, motor rewinding machine and accessories material:mild steelpower source: electricmaximum coil dia:300 mmcapacity:200 coil per 8 hourautomation grade:automaticfrequency:50-60 hzvoltage:220 vphase:single phase., control panel for wiring harness assembly (6 pin 1.5 mm control panel wiring harness assembly) mounted on a table, nema 23 stepper motor, clamp meter - measures ac/dc current, voltage, resistance, and continuity. range: 0-600a, true rms, cat iii/iv safety rating., grounding tester - measures grounding resistance (0-2000 ), 3 or 4-pole testing, portable, battery-operated., electrical equipments - consumable items, 5mm shear cutters, gumboot steel toe safety shoes pvc, industry standard - heavy duty industrial line tester 500 - 750 volt, ring terminal cable connector (conn ring circ 10-12awg), electrical cables-1.0 sq.mm, 2.5sq.mm,4.0 sq.mm, 6.0 sq.mm,10.0 sq.mm, cable wire (min number of equipment - 18 meter spool), jumper wire with clip (35mm double ended crocodile alligator clip with red and black wire electronic components electronic hobby kit), 3 pole miniature circuit breaker 16,20,30a set, 5a,16a electrical connector switch, stainless steel simple wire stripper with clampper, large wire / cable cutter (big head), (size: 10 inch), rubber hand gloves 12inchs, full body safety harnesses for protective construction, mnu industrial safety belt harness full body fall protection with scaffolding hook double lanyard unisex full body adjustable climbing harness safety belt, 12 pieces ring spanner set, industry standard measuring tape - 5m in case, standard (combinat
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For supply of portable miscellaneous workshop equipment - stroboscope freq and rpm , conductivity meter , ph meter , clamp on ultrasonic flowmeter , vibration meter , stroboscope rpm , non contact digital tachometers
Tender For providing of is required to be carried out on gpu 90 kva statcon an-32 s no. 10772 (uid no. 13/gpu-90(f)/i/0044) of 49 sqn to maintained its serviceability through lrp. (a) (b) rotary switch is required to be replaced with new one. rpm/hour meter to be replaced with new one and setting to be carried out. (c) lcd display & keypad to be replaced with new one and necessary configuration as per specification to be reset. (d) charging contractor to be replaced and charging circuit to be repaired. (e) relay 24v 3 c/o & 230v 3 c/o to be replaced with new one. (1) bleeder resistance wom out, required to be replaced with new one. (g) transducer assy required to be replaced with new one and required setting of voltage and current to be reset. (h) functional check of gpu on load to be carried out after repair